Brand:

JUMO ecoTRANS pH 03 202723/888-888-101/000 pH Transmitter

Description

The JUMO ecoTRANS pH 03 version 202723/888-888-101/000 is a DIN-rail transmitter and switching device that turns a pH or redox electrode signal into two isolated analog outputs and one changeover relay. In this order code the two analog outputs and the relay are all present, which is why it is the stock version most often chosen for neutralization and dosing control in water treatment. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; the notes that follow are rewritten from the JUMO data sheet 20.2723.

Role of 202723/888-888-101/000 in a water-treatment panel

The manufacturer lists general water and wastewater management, drinking water, process water, surface water, sea water, swimming pools, wells and aquariums as typical uses. In Omani and GCC projects the match is with desalination post-treatment, effluent neutralization pits, cooling-tower blowdown and hotel pool plants, where a compact DIN-rail module is wired to a pH electrode on one side and to a dosing pump or PLC on the other. The instrument has two analog inputs: the primary input takes a pH or redox electrode, including electrodes with a separate reference and antimony electrodes, and the second input takes a Pt100 or Pt1000 for temperature compensation.

Order code 202723/888-888-101/000 decoded

The code consists of three blocks after the type number. The first 888 stands for the factory-standard input configuration, the second 888 for the factory-standard output arrangement, and the block 101 selects the output hardware: two analog outputs plus one relay output. The suffix 000 means no additional setup software; the sibling code ending in 024 adds the setup program. The stock part number listed in the datasheet for this code is 20/00508663, described as two analog outputs and one relay output. A cheaper stock code, 202723/888-000-000/000 with part number 20/00508665, has one analog output for pH or redox and no relay.

Technical data for 202723/888-888-101/000

Characteristic Value
Measurement range minus 2 to 16 pH, or minus 1500 to plus 1500 mV
Accuracy pH / redox plus or minus 1 percent of the measurement range
A/D converter and sampling 14 bit, 500 ms (two measurements per second)
Temperature input Pt100 or Pt1000, 2-wire, minus 10 to plus 150 degrees Celsius
Analog outputs (two) 0(2) to 10 V, 10 to 0(2) V, 0(4) to 20 mA, 20 to 0(4) mA, galvanically isolated
Relay SPDT, 8 A at 250 V AC or 8 A at 24 V DC resistive, life more than 100,000 operations
Supply 20 to 30 V DC, residual ripple under 5 percent, up to 4 W
Ambient 0 to 50 degrees Celsius operating, IP20, DIN rail 35 mm
Weight approx. 150 g, polycarbonate housing

How 202723/888-888-101/000 differs from other ecoTRANS pH 03 variants

Within the same 202723 family, the 000 output block gives only one analog output with no relay, while the 101 block adds the second analog output, which can carry temperature, and the SPDT relay used for limit value, wiper function or calibration timer. The sibling ending in 024 includes the setup software for PC configuration. All have the same measuring range and 20 to 30 V DC supply. This is also not the larger dTRANS pH 02 or AQUIS 500 pH instruments, which are panel or wall devices with their own displays and more outputs.

Functions that matter in service

The instrument has single-point and two-point calibration for pH, a calibration timer with an adjustable number of days, a binary input that freezes the relay, the outputs and the display during sensor cleaning, and a manual simulation mode for dry commissioning without an electrode. The relay can act as a limit comparator, window or deviation band alarm, with programmable hysteresis and delays. Out-of-range and sensor faults put the analog outputs into a defined low or high state that a PLC can read as an alarm. The device ships with a calibration certificate.

Installation and commissioning

Snap the module onto the 35 mm rail and connect the electrode through screw terminals up to 2.5 mm2. Use the symmetric high-resistance connection in electrically noisy media such as pump or insulation problems, otherwise the common asymmetric connection. Wire the 24 V supply from a SELV or PELV source, scale the outputs, and run a two-point buffer calibration before releasing dosing. The datasheet names an optional PC interface cable and setup program for backup and printing of the configuration.

Maintenance

The instrument itself needs little more than periodic checking of terminals and output scaling; the work lies with the electrode and its buffers. Use the calibration timer to prompt regular two-point calibrations, and keep the configuration file so that a replacement module for 202723/888-888-101/000 can be loaded quickly.

Matching sensors and loop wiring for 202723/888-888-101/000

The input accepts pH or redox combination electrodes, glass or metal electrodes with a discrete reference electrode, and antimony electrodes, so the existing sensor stock at a site can usually be kept. The instrument displays redox either in mV or freely scaled and offers a percentage display for redox calibration. The analog outputs are scalable with a minimum span of 10 percent of the measurement range, and their characteristic curve deviation is stated as not more than 0.075 percent of the measurement range, so a dosing controller or PLC receives a clean signal. Temperature can be taken from a Pt100 or Pt1000 on the second input, entered manually, or monitored through the relay; a temperature offset of minus 20 to plus 20 degrees Celsius can correct a sensor installation error.

When wiring 202723/888-888-101/000, keep the high-impedance electrode cable short and separated from motor cables, and use a suitable cable for the symmetric connection if the medium is electrically disturbed. Ensure the relay load stays inside the stated 8 A rating, and use an interposing relay for large contactors.

Documents and quotation

The JUMO 202723 datasheet is attached. To request a quotation for 202723/888-888-101/000, send the order code, the quantity and your delivery location in Oman or the GCC through the RFQ form.

Datasheets & Documents
  • PDF Datasheet JUMO ecoTRANS pH 03 202723/888-888-101/000 pH Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.

Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.

JUMO company profile

Established 1948, Fulda, Germany, by Moritz Kurt Juchheim
First products Glass and contact thermometers; platinum glass sensors from 1966
Ownership Family-owned; renamed JUMO GmbH & Co. KG in 2003
Product families RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments

Milestones

  • 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
  • 1966: Platinum glass temperature sensors are added.
  • 2003: The parent company is renamed JUMO GmbH & Co. KG.

JUMO products we list

Family Models Typical use
RTD and thermocouple probes 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp Temperature measurement in pipes, vessels, machines, HVAC and food plants
Thermowells and inserts 909710 thermowells, 909740 measuring inserts Protecting sensors and replacing them without opening the process
Temperature transmitters dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch Converting sensor signals to 4-20 mA, HART or IO-Link
Pressure and level dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 Pressure in process, hydraulic and OEM systems; tank and well level
Controllers, limiters and recorders DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T Furnace, oven and process control, over-temperature protection and recording
Liquid analysis and flow AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 pH, conductivity, oxygen and turbidity in water treatment; liquid flow

Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.

Where JUMO products are used

In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.

Ordering JUMO products: what we need

Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.

Facts checked against JUMO's company history, October 2026.

FAQ

Questions about the JUMO ecoTRANS pH 03 202723/888-888-101/000 pH

Answers from our engineering team on installation, compatibility and integration.

01What outputs does 202723/888-888-101/000 provide?
The 101 output block means two galvanically isolated analog outputs, freely configurable for 0(2) to 10 V or 0(4) to 20 mA, plus one SPDT changeover relay.
02What does 202723/888-888-101/000 measure and compensate?
It measures pH from minus 2 to 16 or redox from minus 1500 to plus 1500 mV, and the second input takes a Pt100 or Pt1000 for temperature compensation between minus 10 and plus 150 degrees Celsius.
03What supply does 202723/888-888-101/000 need?
The datasheet gives 20 to 30 V DC with residual ripple below 5 percent, power consumption up to 4 W, reverse polarity protection, for SELV or PELV circuits only.
04How does 202723/888-888-101/000 differ from 202723/888-888-101/024?
The 024 suffix adds the PC setup software to the same hardware; the 000 suffix of this code is the unit alone, so a PC cable and software are bought separately.
05What can the relay of 202723/888-888-101/000 do?
It can work as min or max limit comparator, window or deviation alarm, wiper pulse, or calibration timer signal, rated 8 A at 250 V AC resistive with programmable hysteresis and delay.