- Automation & ControlView all 2,894 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Welding Consumables
TIG Welding Wire
TIG welding wire, supplied as straight cut-length rods for the GTAW process, is used where root quality and corrosion resistance matter more than deposition rate. Seven Star LLC in Muscat, Oman lists TIG filler rods from Böhler Welding, Ador Welding and LongTeng, including ER70S-6 and ER70S-3 for carbon steel, ER308L, ER316L and ER309L for stainless steel, ER2209 for 22Cr duplex stainless steel, ER2594 for super duplex, and ER90S-B3 and ER80S-B2 for chrome-moly steel. The range is growing, and other grades such as nickel alloy rods can be sourced on request.
Read the full category guide ↓- 15 products
- 3 brands

15 products
Category guide
About TIG Welding Wire
15 products · 3 brands
TIG welding wire, supplied as straight cut-length rods for the GTAW process, is used where root quality and corrosion resistance matter more than deposition rate. Seven Star LLC in Muscat, Oman lists TIG filler rods from Böhler Welding, Ador Welding and LongTeng, including ER70S-6 and ER70S-3 for carbon steel, ER308L, ER316L and ER309L for stainless steel, ER2209 for 22Cr duplex stainless steel, ER2594 for super duplex, and ER90S-B3 and ER80S-B2 for chrome-moly steel. The range is growing, and other grades such as nickel alloy rods can be sourced on request.
Duplex, super duplex and chrome-moly TIG rods
Duplex fillers contain more nickel than the base metal, so the weld keeps a balanced ferrite and austenite structure after cooling. Root passes need an inert back purge, and heat input and interpass temperature are held within the limits of the procedure, because both too little and too much heat upset the phase balance. These rods are typical for seawater, produced water and desalination piping across the GCC. ER90S-B3, classified under AWS A5.28, is used for roots and small-bore joints in boiler and refinery piping, followed by post-weld heat treatment where the code requires it.
Information to include with a TIG rod inquiry
Give the AWS classification, rod diameter, quantity in kilograms and the certificate type. Mention any project requirement on the weld metal, such as a ferrite range or pitting corrosion testing, and the base metal grade, so we can check the match against the manufacturer datasheet.
What to include in your inquiry
These details let us quote the right item the first time.
- AWS or EN classification
- Diameter
- Base material to be welded
- Packaging (spool, drum, kg) and quantity
- Approvals or certificates required
Missing some of them? Send what you have. A nameplate photo or an old part number is enough to start.
Brands in TIG Welding Wire
All brands →Related categories
Most viewed in TIG Welding Wire
Guides and articles
All articles →Request a Quote for TIG Welding Wire
Looking for a specific model, part number or brand in TIG Welding Wire? Send us your requirements and quantities. Seven Star LLC sources genuine industrial equipment for customers across Oman and the GCC and replies with a formal quotation.
- Genuine OEM products
- Supply across Oman & the GCC
- Formal quotation from our sales team
Free, no-obligation quotation · takes about 1 minute
Other enquiries: [email protected] · WhatsApp
FAQ
Questions about TIG Welding Wire
Common questions about selecting and sourcing TIG Welding Wire for projects in Oman and the GCC.
01When is ER2209 used and when is ER2594 required?
ER2209 is the matching filler for 22Cr duplex grades such as UNS S31803 and S32205. ER2594 is a 25Cr super duplex filler for grades such as S32750 and S32760, where higher pitting resistance is needed. Using the lower-alloyed 2209 on super duplex gives a weld that is less corrosion resistant than the pipe, so procedures normally do not allow it.
02Can ER2209 be used for joints between duplex and carbon steel or austenitic stainless?
It is a common choice for those dissimilar joints, and 309L-type fillers are another option. Which one applies depends on the design temperature, the corrosion requirement on the weld and what the client specification allows. The decision belongs to the qualified procedure. Send both base metal grades and we will check which fillers the manufacturer documentation recommends.
03Which shielding and purge gas do duplex TIG welds need?
Argon is the standard shielding gas, and the root side must be purged until oxygen is low enough to avoid heavy heat tint. Some procedures add a small percentage of nitrogen to the shielding or purge gas to limit nitrogen loss from the root, which helps the austenite content. Use exactly the gases written in the qualified procedure.
04How are TIG rods identified and kept from being mixed up?
Rods are normally stamped or flag-tagged with the classification, and packed in tubes labeled with the batch number. Keep them in the original tube, issue one grade per welder at a time, and never return loose unmarked rods to the store. On alloy piping, a mixed-up rod is usually found only at positive material identification, after the weld is finished.
05Can you supply other TIG filler grades, and what data do you need?
Yes. Other grades, for example nickel alloy rods, can be sourced on request. Send the AWS classification, diameter, quantity in kilograms, base metal grade and the certificate type required. If your procedure names a particular brand or trade designation, include it so the offer matches what was qualified.


























