- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: JUMO
JUMO AQUIS 500 Ci 202566/20-888-888-310-310-23/000
Description
JUMO AQUIS 500 Ci, ordered as 202566/20-888-888-310-310-23/000, is the fully equipped stock version of the JUMO transmitter and controller for inductive (toroidal) conductivity, concentration and temperature: wall-mounted housing, two analog outputs, two changeover relays and a wide-range mains supply. Because the inductive principle has no electrodes that can polarize or foul, this instrument is picked where the liquid is dirty, oily, scaling or aggressive, the situations in which a two-electrode cell would struggle. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Why choose 202566/20-888-888-310-310-23/000 for dirty or corrosive liquids
The datasheet recommends the instrument for media with heavy deposits from contaminants, oil and grease, or gypsum and lime precipitation, and lists dairies, breweries, soft-drink bottling, mineral springs, drinking water, CIP and SIP systems and concentration measurement of acids, lyes and cleaning chemicals as areas of use. In Gulf industry the same logic fits seawater-fed cooling and desalination brine, chemical dosing skids at petrochemical plants, caustic and acid regeneration of demineralizer beds, and bottling and dairy lines. Inductive JUMO cells, such as the tecLine Ci named in the data sheet, are connected to the instrument.
How the code 202566/20-888-888-310-310-23/000 is built
Basic type extension 20 is the surface-mounted housing, with IP67 protection; extension 10 is the panel-mount version with IP65 at the front. Output 1 and Output 2 are both 888, an analog output 0(4) to 20 mA and 0 to 10 V, which can carry the main value, the temperature or a continuous PID controller output. Output 3 and Output 4 are both 310, a relay with changeover contact each, configurable as limit controller, pulse-width, pulse-frequency or modulating controller, washing timer or calibration timer alarm. Power supply 23 is 110 to 240 V AC, plus 10 and minus 15 percent, 48 to 63 Hz, and the extra code 000 is none. The stock part number is 00542691.
Technical data for 202566/20-888-888-310-310-23/000
| Item | Datasheet value |
|---|---|
| Measured variables | Inductive conductivity, concentration, temperature |
| Conductivity ranges | 0 to 9999 microsiemens per cm up to 0 to 2000 mS/cm, in several display formats |
| Concentration tables | NaOH, HNO3, H2SO4, HCl in several by-weight ranges, plus a customised table |
| Temperature input | Pt100 or Pt1000 (auto detection), minus 50 to plus 250 degrees Celsius; NTC/PTC up to 4 kilohms |
| Temperature accuracy | plus or minus 0.5 K up to 100 degrees Celsius |
| Compensation | off, linear (0 to 5.5 percent per degree), natural water ISO 7888, non-linear |
| Cell constant adjustment | 4 to 6 or 6 to 8 per cm, relative cell constant 80 to 120 percent |
| Outputs | 2 analog (0(4) to 20 mA, 0 to 10 V), 2 changeover relays |
| Supply | 110 to 240 V AC |
| Housing protection | IP67 surface mounting |
How 202566/20-888-888-310-310-23/000 differs from other AQUIS 500 variants
The AQUIS 500 platform shares one housing across types 202560 for pH, 202565 for conductive conductivity, 202566 for inductive conductivity, 202568 for standard signals and 202569 for digital sensors. Within 202566, the other order choices are panel mounting instead of surface mounting, a single analog output or none, relays removed, and 12 to 24 V DC or 20 to 30 V AC/DC power. The code 202566/20-888-888-310-310-23/000 is the maximum configuration: both analog outputs and both relays, mains powered, wall-mounted.
Operation and diagnostics
The large backlit graphic LC display shows large numbers, a bar graph or a trend, and parameters are in plain text with a code-word protection. A calibration logbook records cell-constant and temperature-coefficient calibrations, a binary input can inhibit the keyboard, hold outputs or stop alarms, and a setup program offers documentation and later loading of extra languages beyond German, English and French.
Installation and commissioning
Mount on a wall or, with the pipe installation set 00483664, on a pipe or support pillar; a protective roof 00398161 helps in outdoor sun. Connect the inductive cell and the integrated temperature sensor, apply mains power, select the measured variable and the compensation, then calibrate with the calibration adapter for inductive conductivity measurement, type 202711/21, part 00543395, which the datasheet lists for initial commissioning.
Maintenance
Inductive cells need cleaning rather than electrode replacement. Use the calibration timer and logbook of 202566/20-888-888-310-310-23/000 to schedule checks, keep the setup file for fast replacement, and verify relay set points after any change of the process chemistry.
Using the controller outputs of 202566/20-888-888-310-310-23/000
Beyond measuring, the AQUIS 500 Ci is a controller. The first two analog outputs can serve as a continuous controller output with PID action, while the relays can run limit control, pulse-width control, pulse-frequency control or modulating control, also with PID action. A typical Gulf use is acid or caustic strength control in a regeneration or rinse circuit: the concentration reading by weight drives a metering pump through the pulse-frequency output, and the second relay raises a high-alarm. Another common use is phase detection in clean-in-place lines, where the conductivity step between water and chemical switches a valve through the limit controller, and the washing timer relay signals when a cleaning cycle is due.
The datasheet also gives accuracy limits that matter in specification: a deviation of the conductivity measurement of 1 to 1.5 percent of the measuring range depending on the range, and a temperature input accuracy of plus or minus 0.5 K up to 100 degrees Celsius for a Pt100, with 0.05 percent per 10 degrees Celsius ambient temperature error. These values allow 202566/20-888-888-310-310-23/000 to be written into loop specifications with real numbers rather than assumptions.
Documents and quotation
The JUMO 202566 datasheet is attached. For a quotation on 202566/20-888-888-310-310-23/000, send the full order code, the quantity and your delivery location in Oman or the GCC through the RFQ form.
Other Models in the AQUIS 500 Transmitters And Controllers Range
Seven Star LLC supplies models from the AQUIS 500 Transmitters And Controllers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| JUMO AQUIS 500 RS 202569/20-654-888-888-310-310-23/000 | Liquid Analytical Systems | View details |
| JUMO AQUIS 500 Ci 202566/20-888-888-310-310-23/000 | Liquid Analytical Systems | You are viewing this model |
Datasheets & Documents
- Datasheet JUMO AQUIS 500 Ci 202566/20-888-888-310-310-23/000 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.
Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.
JUMO company profile
| Established | 1948, Fulda, Germany, by Moritz Kurt Juchheim |
|---|---|
| First products | Glass and contact thermometers; platinum glass sensors from 1966 |
| Ownership | Family-owned; renamed JUMO GmbH & Co. KG in 2003 |
| Product families | RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments |
Milestones
- 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
- 1966: Platinum glass temperature sensors are added.
- 2003: The parent company is renamed JUMO GmbH & Co. KG.
JUMO products we list
| Family | Models | Typical use |
|---|---|---|
| RTD and thermocouple probes | 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp | Temperature measurement in pipes, vessels, machines, HVAC and food plants |
| Thermowells and inserts | 909710 thermowells, 909740 measuring inserts | Protecting sensors and replacing them without opening the process |
| Temperature transmitters | dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch | Converting sensor signals to 4-20 mA, HART or IO-Link |
| Pressure and level | dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 | Pressure in process, hydraulic and OEM systems; tank and well level |
| Controllers, limiters and recorders | DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T | Furnace, oven and process control, over-temperature protection and recording |
| Liquid analysis and flow | AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 | pH, conductivity, oxygen and turbidity in water treatment; liquid flow |
Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.
Where JUMO products are used
In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.
Ordering JUMO products: what we need
Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.
Facts checked against JUMO's company history, October 2026.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
FAQ
Questions about the JUMO AQUIS 500 Ci 202566/20-888-888-310-310-23/000
Answers from our engineering team on installation, compatibility and integration.
01What do the two 310 blocks in 202566/20-888-888-310-310-23/000 mean?
Outputs 3 and 4 are both relay outputs with changeover contact, which the datasheet allows to be configured as limit controllers, pulse controllers, a washing timer or a calibration alarm.
02Which cells can connect to 202566/20-888-888-310-310-23/000?
Inductive JUMO conductivity cells can be connected, such as the tecLine Ci named in the datasheet, with Pt100, Pt1000 or NTC/PTC temperature compensation.
03Can 202566/20-888-888-310-310-23/000 measure concentration?
Yes. Besides specific conductivity it offers direct selection of NaOH, HNO3, H2SO4 and HCl concentration ranges in percent by weight, or a customised table.
04What power supply does 202566/20-888-888-310-310-23/000 use?
Power supply code 23 is 110 to 240 V AC, plus 10 and minus 15 percent, 48 to 63 Hz; other versions use 20 to 30 V AC/DC or 12 to 24 V DC.
05What is the stock part number of 202566/20-888-888-310-310-23/000?
The data sheet lists 00542691, delivered in 3 days after receipt of order, with accessories such as the protective roof and the pipe installation set on a separate 10-day basis.


















Reviews
There are no reviews yet.