- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: JUMO
JUMO AQUIS 500 RS 202569/20-654-888-888-310-310-23/000
Description
When JUMO sells a disinfectant, oxygen or turbidity sensor with a digital Modbus interface, the instrument it expects at the other end of the cable is the AQUIS 500 RS. The stock version 202569/20-654-888-888-310-310-23/000 is the fully equipped model: an RS485 Modbus master input, two analog outputs, two changeover relays, a wall housing and a 110 to 240 V AC supply. It is not a transmitter for raw electrodes; it is the display, supply and controller stage for sensors that already carry their own electronics. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Sensors supported by 202569/20-654-888-888-310-310-23/000
The datasheet names dissolved oxygen sensors of data sheets 202614 and 202613, free chlorine 202630, total chlorine 202631, chlorine dioxide and ozone 202634, hydrogen peroxide and peracetic acid 202636, bromine 202637, and turbidity 202670. Those are the measurements that drive swimming-pool, drinking-water, cooling-water and wastewater biological stages in the Gulf, which makes the controller useful for municipal chlorination, hotel and resort pools, seawater disinfection and aeration monitoring in sewage treatment plants. The instrument also supplies the sensor with 24 V DC up to 30 mA or 5 V DC up to 100 mA, and accepts an extra Pt100, Pt1000 or NTC/PTC probe if the digital sensor has no temperature element.
Decoding the order string 202569/20-654-888-888-310-310-23/000
The basic type is 202569. Extension 20 is the surface-mounted case with IP67, extension 10 would be panel mounting. The input block 654 means the RS485 Modbus master interface. Outputs 1 and 2 are both 888: analog outputs of 0(4) to 20 mA or 0 to 10 V, assignable to the main value, the temperature or a continuous controller. Outputs 3 and 4 are both 310: changeover relays. The supply code 23 is 110 to 240 V AC, plus 10 and minus 15 percent, 48 to 63 Hz, and the extra code 000 means none. The datasheet lists the part number 00602275 and delivery within three working days.
Technical data for 202569/20-654-888-888-310-310-23/000
| Parameter | Datasheet value |
|---|---|
| Digital input | RS485 Modbus master, baud rates from 2400 to 38400 Bd |
| Temperature input | Analog, Pt100, Pt1000 or NTC/PTC up to 4 kilohms, 0.3 percent |
| Sensor supply | 24 V DC (20.4 to 28.8 V), 30 mA; 5 V DC, 100 mA |
| Binary input supply | 12 V DC, 10 mA |
| Analog outputs | Two, 0(4) to 20 mA or 0 to 10 V, 0.25 percent accuracy, isolated |
| Relays | Two changeover contacts |
| Display units | mg/l, ppm, percent SAT, percent, per mille, g/l, ppb, micrograms/l, NTU, FNU |
| Calibration | Zero point, end value or two-point, with calibration log file |
| Protection | IP67 surface mounting, IP65 front for panel mounting |
How 202569/20-654-888-888-310-310-23/000 differs from other AQUIS 500 RS variants
Three stock codes exist. The 202569/20-654-888-000-000-000-23/000 (part 00613453) has one analog output and no relay; 202569/20-654-888-000-310-000-23/000 (part 00602276) has one analog output and one relay; this one, 00602275, has two analog outputs and two relays. The AQUIS 500 pH, CR, Ci and AS siblings measure from raw electrodes or standard signals, but the RS reads only Modbus digital sensors and has no analog measuring input except temperature.
Operation, logs and diagnostics
Three display modes give large digits, a bar graph or a trend. A calibration log file records past calibrations, and a min and max memory stores extremes of the inputs. The calibration timer can notify when a recalibration is due, and the sampling interval of the digital interface is fixed at 500 ms. Controller functions include limit values, alarm windows, alarm pulse contacts and P, PI, PD or PID control on the relays and outputs, with alarm suppression for the controller alarm.
Installation and commissioning
Mount the case on a wall or a pipe; a ventilation screw with a PTFE membrane prevents condensation. Connect the digital sensor to the RS485 terminals, choose the sensor type so the Modbus addresses, byte sequence and baud rate are preset, then run the sensor-specific zero or two-point calibration. Check relay assignments before releasing a dosing pump.
Maintenance of 202569/20-654-888-888-310-310-23/000
The controller needs little maintenance, while the sensors are consumables with membrane caps or electrolyte; keep the calibration log and replace sensors as the datasheet of each sensor describes. A saved setup file speeds replacement of 202569/20-654-888-888-310-310-23/000.
Modbus setup and sensor integration for 202569/20-654-888-888-310-310-23/000
Because the input of 202569/20-654-888-888-310-310-23/000 is a Modbus master, the instrument does not need to know the electrochemistry of the sensor; it reads registers. For the JUMO sensors the sensor type can simply be selected from a list, which loads the matching register addresses, byte sequence and baud rate. For other Modbus sensors, the optional setup program allows the Modbus addresses for the measured value and temperature value, the byte sequence of the transfer and the transfer speed between 2400 and 38400 Bd to be configured, subject to the datasheet statement that the digital interface runs at a fixed 500 ms interval. Cable length and screening follow the RS485 rules of the sensor manufacturer, so keep the run away from power cables and terminate the bus where required.
For measurement of disinfectants the datasheet identifies membrane-covered amperometric sensors with digital interface such as the tecLine Cl2 for free chlorine in types 202630/50 and 202630/53, and the display can also be set to percent saturation for dissolved oxygen, NTU or FNU for turbidity. This flexibility is why one 202569/20-654-888-888-310-310-23/000 instrument can be re-used between different loops when sensors are exchanged, as long as the sensor type is reselected and the relay and output assignments are reviewed.
Documents and quotation
The JUMO 202569 datasheet is attached. For a quotation on 202569/20-654-888-888-310-310-23/000, send the full order code, the quantity and your delivery location in Oman or the GCC through the RFQ form.
Other Models in the AQUIS 500 Transmitters And Controllers Range
Seven Star LLC supplies models from the AQUIS 500 Transmitters And Controllers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| JUMO AQUIS 500 RS 202569/20-654-888-888-310-310-23/000 | Liquid Analytical Systems | You are viewing this model |
| JUMO AQUIS 500 Ci 202566/20-888-888-310-310-23/000 | Liquid Analytical Systems | View details |
Datasheets & Documents
- Datasheet JUMO AQUIS 500 RS 202569/20-654-888-888-310-310-23/000 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.
Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.
JUMO company profile
| Established | 1948, Fulda, Germany, by Moritz Kurt Juchheim |
|---|---|
| First products | Glass and contact thermometers; platinum glass sensors from 1966 |
| Ownership | Family-owned; renamed JUMO GmbH & Co. KG in 2003 |
| Product families | RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments |
Milestones
- 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
- 1966: Platinum glass temperature sensors are added.
- 2003: The parent company is renamed JUMO GmbH & Co. KG.
JUMO products we list
| Family | Models | Typical use |
|---|---|---|
| RTD and thermocouple probes | 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp | Temperature measurement in pipes, vessels, machines, HVAC and food plants |
| Thermowells and inserts | 909710 thermowells, 909740 measuring inserts | Protecting sensors and replacing them without opening the process |
| Temperature transmitters | dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch | Converting sensor signals to 4-20 mA, HART or IO-Link |
| Pressure and level | dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 | Pressure in process, hydraulic and OEM systems; tank and well level |
| Controllers, limiters and recorders | DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T | Furnace, oven and process control, over-temperature protection and recording |
| Liquid analysis and flow | AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 | pH, conductivity, oxygen and turbidity in water treatment; liquid flow |
Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.
Where JUMO products are used
In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.
Ordering JUMO products: what we need
Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.
Facts checked against JUMO's company history, October 2026.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
FAQ
Questions about the JUMO AQUIS 500 RS
Answers from our engineering team on installation, compatibility and integration.
01Which sensors does 202569/20-654-888-888-310-310-23/000 support?
It reads JUMO digital Modbus sensors for dissolved oxygen, free and total chlorine, chlorine dioxide and ozone, hydrogen peroxide and peracetic acid, bromine and turbidity, as listed in the datasheet.
02What does 654 mean in 202569/20-654-888-888-310-310-23/000?
The input block 654 is an RS485 Modbus master interface, with baud rates selectable from 2400 up to 38400 Bd and a fixed 500 ms sampling interval.
03How many outputs does 202569/20-654-888-888-310-310-23/000 have?
It has two analog outputs (0(4) to 20 mA or 0 to 10 V) and two changeover relays, because both output blocks read 888 and both relay blocks read 310.
04Can 202569/20-654-888-888-310-310-23/000 power the sensor?
Yes. The instrument supplies 24 V DC up to 30 mA or 5 V DC up to 100 mA to digital sensors, so no extra power supply is needed for those sensors.
05What is the stock part number of 202569/20-654-888-888-310-310-23/000?
The stock list gives 00602275, with delivery within three working days of order receipt, while the accessories ship in ten working days.


















Reviews
There are no reviews yet.