Electrical & Power

The Electrical & Power category covers the equipment that distributes, protects and conditions electrical power in industrial plants. Seven Star LLC supplies circuit breakers, protection relays, motor control components, power supplies, cable glands and cable accessories to contractors, panel builders and plant electrical teams in Oman. Schneider Electric is the largest brand among the listed items, followed by Mean Well, ABB, Eaton, Siemens and Schweitzer Engineering Laboratories (SEL), with hazardous-area cable glands and fittings from CMP Products and Ex components from R. STAHL.

Read the full category guide
  • 1,869 products
  • 63 brands
  • 8 sub-categories
Electrical & Power supplied by Seven Star LLC in Oman

Category guide

About Electrical & Power

1869 products 63 brands 8 sub-categories

The Electrical & Power category covers the equipment that distributes, protects and conditions electrical power in industrial plants. Seven Star LLC supplies circuit breakers, protection relays, motor control components, power supplies, cable glands and cable accessories to contractors, panel builders and plant electrical teams in Oman. Schneider Electric is the largest brand among the listed items, followed by Mean Well, ABB, Eaton, Siemens and Schweitzer Engineering Laboratories (SEL), with hazardous-area cable glands and fittings from CMP Products and Ex components from R. STAHL.

Sub-categories of electrical and power equipment

Circuit Breakers is the largest group. It holds miniature circuit breakers, RCBOs and residual current modules for final circuits, molded case circuit breakers with electronic trip units for distribution boards, motor circuit breakers, load break and disconnect switches, medium-voltage vacuum circuit breakers such as the ABB VD4, and protection relays from SEL, Siemens SIPROTEC, ABB and Schneider Electric PowerLogic.

Power Modules covers DIN-rail and enclosed power supplies from Mean Well, Weidmüller, Phoenix Contact and Finder, rectifier modules, system power supply modules for controllers, and Ex plugs and sockets from R. STAHL. Electrical Tapes & Cable Accessories is a new sub-category for insulating tapes, jointing materials and cable glands from CMP and Hawke. Contactors & Overload Relays holds contactors, solid state relays and thermal overload relays. Items that sit directly in the parent category include switchboard systems, enclosures, cables and cable cleats.

Selection parameters for protection and distribution equipment

Low-voltage breakers are specified by rated current, number of poles, breaking capacity at the system voltage, trip curve or trip unit type, and the standard they are built to. IEC 60898-1 applies to miniature breakers for household and similar use, IEC 60947-2 to industrial breakers, and UL standards to North American equipment, so a Class J fuse or UL-listed breaker is not interchangeable on paper with an IEC device. Protection relays are defined by function (feeder, motor, transformer or differential), CT and VT inputs, auxiliary voltage, binary I/O count and communication protocol such as IEC 61850 or Modbus. In relays, those choices are encoded in a long order code.

What to send for an electrical supply inquiry

Send the manufacturer reference for each item. Where that is missing, give system voltage and frequency, rated current, fault level, poles and the application. For projects in the GCC, mention the utility or client specification the equipment must meet and the documents required. The manufacturer’s datasheet and the certificates the manufacturer issues are provided on request.

What to include in your inquiry

These details let us quote the right item the first time.

  • Manufacturer part number or catalogue reference
  • Rated current and voltage
  • Breaking capacity and number of poles
  • Trip unit and accessories
  • Quantity

Missing some of them? Send what you have. A nameplate photo or an old part number is enough to start.

Request a Quote for Electrical & Power

Looking for a specific model, part number or brand in Electrical & Power? Send us your requirements and quantities. Seven Star LLC sources genuine industrial equipment for customers across Oman and the GCC and replies with a formal quotation.

Free, no-obligation quotation · takes about 1 minute

Other enquiries: [email protected] · WhatsApp

FAQ

Questions about Electrical & Power

Common questions about selecting and sourcing Electrical & Power for projects in Oman and the GCC.

01What is the difference between an MCB, an MCCB and a vacuum circuit breaker?
A miniature circuit breaker protects final circuits at low current with a fixed trip characteristic. A molded case circuit breaker handles higher currents and fault levels in distribution boards and usually has an adjustable thermal-magnetic or electronic trip unit. A vacuum circuit breaker interrupts the arc in a sealed vacuum interrupter and is used in medium-voltage switchgear, tripped by a separate protection relay.
02How do I replace a breaker or relay that is no longer manufactured?
Give us the complete reference and, for a breaker, the frame, trip unit and accessories fitted, such as shunt trip, auxiliary contacts or motor operator. We check the manufacturer documentation for the named successor. For withdrawable breakers and medium-voltage units, the cradle and panel dimensions must be confirmed, and manufacturers often offer a retrofit version designed to fit the existing switchgear.
03Which documents can be supplied with electrical protection equipment?
On request we provide the manufacturer's datasheet and the documents the manufacturer issues for the item. These typically include the declaration of conformity, the routine test report for medium-voltage breakers and relays where the factory issues one, type test certificate references, and a certificate of origin. State the required documents in the inquiry, because some have to be requested from the factory with the order.
04Can an IEC breaker be used in place of a UL-listed one?
Not without engineering review. IEC and UL devices are tested to different standards, and their ratings, markings and dimensions differ. A panel built and listed to UL requirements needs UL-listed or recognized components to keep its listing, and an IEC switchboard is verified with IEC components. Tell us which standard the panel follows and we offer the item from the corresponding product line.
05Why do protection relays have such long order codes?
Each position in the code selects a hardware or software option: current and voltage input ratings, auxiliary supply range, number of binary inputs and outputs, communication ports and protocols, mounting and front panel type, and the function package. Two relays of the same family can be incompatible in a panel if one position differs. Copy the full code from the nameplate, not from a drawing.
06What information do you need to quote circuit breakers or power supplies?
The manufacturer reference and quantity come first. For breakers without a reference: rated current, poles, system voltage, breaking capacity, trip curve or trip unit, fixed or withdrawable version and accessories. For power supplies: input voltage and phases, output voltage and current, mounting and approvals. For cable glands: cable type and diameters, thread, material and Ex protection type.