Liquiline CM442 Multiparameter Transmitter
Description
Overview
The Liquiline CM442 is Endress+Hauser’s state-of-the-art 1-/2-channel multiparameter transmitter for pH, ORP, conductivity, oxygen, chlorine, turbidity, sludge level, SAC, nitrate, and many other liquid analysis parameters. Built on the modular Liquiline platform, the CM442 allows up to 2 Memosens digital sensors of choice from over 12 measurement parameters to be connected to a single robust field transmitter.
With fast quotation turnaround and technical support, Seven Star LLC proudly offers the Liquiline CM442 to water and wastewater treatment plants, food and beverage producers, and chemical processing facilities across the Sultanate of Oman, Muscat, and the wider GCC. Its universal modules minimize spare part stock while its automatic sensor recognition and hot plug-and-play capability with pre-calibrated Memosens sensors dramatically simplify commissioning and maintenance for plant technicians managing dozens of analysis points across a treatment facility.
Measurement Principle
The Liquiline CM442 operates on Memosens digital sensor technology, which converts the measured value to a digital signal at the sensor itself and transfers it to the transmitter without a contacting connection. This non-contact, digital signal transmission enables optimum galvanic isolation, eliminates contact corrosion, and results in a completely watertight measuring point, while also supporting laboratory sensor calibration for increased measured value availability.
Memosens technology further enables predictive maintenance by recording sensor data such as total operating hours, hours of operation with high or low measured values, hours at high temperatures, and sensor condition history. Depending on the sensor connected, the CM442 supports potentiometric pH/ORP measurement, conductive and inductive conductivity measurement, amperometric dissolved oxygen measurement, four-beam alternating light turbidity measurement, and ultrasonic sludge level detection, among others.
Engineering Design of the Liquiline CM442
The Liquiline CM442 features a robust plastic housing (PC-FR base, EPDM seal) rated IP66/IP67, suitable for all non-Ex applications, with overall dimensions of 237 x 194 x 162mm. Its ambient operating temperature range spans -20°C to +60°C, and the transmitter accepts 1 to 2 Memosens digital inputs as standard, with optional 2x 0/4-20mA current inputs and 2x digital inputs.
Output and communication options include 2 to 8 current outputs (0/4-20mA), alarm relay, up to 2 relays, and digital fieldbus support via PROFIBUS DP, Modbus RS485/RTU, Modbus TCP, EtherNet/IP, and PROFINET, plus an integrated webserver for remote diagnostics, configuration, and parameter access from any browser, including smartphones. The modular design requires a platform upgrade beyond two measuring channels, and configuration can be saved to an SD card for fast duplicate setup across multiple installations.
Key Features
The Liquiline CM442 combines Memosens digital sensor connectivity with flexible modular expansion. Core capabilities include:
- Connects up to 2 Memosens digital sensors across 12+ measurement parameters.
- Automatic sensor recognition with hot plug-and-play, pre-calibrated Memosens sensors.
- One or two digital sensor channels, depending on configuration.
- IP66/IP67-rated robust plastic housing for all non-Ex applications.
- Integrated webserver for remote configuration and diagnostics via any browser.
- HART, PROFIBUS DP, Modbus RS485/RTU/TCP, EtherNet/IP, and PROFINET connectivity.
- Heartbeat Technology for status-oriented maintenance and measuring point verification.
- SD card configuration backup for rapid setup on duplicate installations.
Industrial Applications
The Liquiline CM442 is well suited to municipal water and wastewater treatment, food and beverage processing, power generation, and chemical facilities across Oman requiring reliable, expandable multiparameter liquid analysis. Its universal module concept and standardized Liquiline spare parts reduce inventory costs while its Ex-extendable design allows connection of sensors installed in hazardous areas via IECEx, ATEX, and CSA-approved modules.
With engineering support in Muscat, Seven Star LLC supports water utilities, food processing plants, and industrial facilities throughout the Sohar and Salalah economic zones and the broader GCC region with the Liquiline CM442’s proven multiparameter analysis platform.
Technical Specifications
Full technical parameters for the Liquiline CM442 multiparameter transmitter:
| Parameter | Specification |
|---|---|
| Model | Liquiline CM442 |
| Channels | 1 to 2 Memosens Digital Inputs |
| Supported Parameters | pH, ORP, Conductivity, Oxygen, Chlorine, Turbidity, Sludge Level, SAC, Nitrate |
| Housing | PC-FR Plastic, EPDM Seal, IP66/IP67 |
| Dimensions | 237 x 194 x 162mm |
| Ambient Temperature | -20°C to +60°C |
| Outputs | 2 to 8x 0/4-20mA, Alarm Relay, Up to 2 Relays |
| Communication | HART, PROFIBUS DP, Modbus RS485/TCP, EtherNet/IP, PROFINET |
| Certificates | EAC, cCSAus, MCERTS |
Expanding a CM442 installation
A CM442 supports one or two digital measuring channels. For additional sensors, identify the installed base module and power supply. Endress+Hauser lists the hardware needed to upgrade the instrument to a CM444 or CM448 in its expansion table.
CM442 manufacturer technical reference
Why Choose Seven Star LLC for Multiparameter Liquid Analysis
A Liquiline platform’s real value comes from standardizing a plant’s entire liquid-analysis fleet around one Memosens-compatible transmitter family, but that only pays off if the sensor types, channel count, and communication protocol are planned across the whole facility rather than ordered site by site. Seven Star LLC’s engineers review a customer’s full analysis-point list – pH, conductivity, dissolved oxygen, turbidity, and the rest – before quoting, so the CM442’s channel and module configuration matches actual current and near-term future needs rather than requiring a second unit later. We also help plan a shared Memosens sensor spares pool across a treatment plant’s transmitter fleet, since the sensors themselves are interchangeable across compatible Liquiline units, and we coordinate delivery and commissioning support across water and wastewater facilities in Muscat, Sohar, and the broader GCC.
Request a Quote for Liquiline CM442 Multiparameter Transmitter
To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Liquiline CM442 Multiparameter Transmitter, please contact the instrumentation division at Seven Star LLC today. Backed by manufacturer datasheet documentation, our engineers are ready to assist with rapid sourcing for your liquid analysis and process monitoring projects.
Related Products
- ABB-Color analyzer Aztec AW637
- SADP-P SHAW Automatic DewPoint Meter
- ABB-AK100 Hydrogen Purity Monitor
- ABB-Phosphate analyzer Aztec AW636
- VISCOSITE™ In-Line Viscometer
- ABB-AX410
See also: Endress+Hauser Liquiline CM444 4-Channel Memosens Multiparameter Transmitter.
Datasheets & Documents
- Instruction Manual Endress+Hauser (E & H) Liquiline CM442 Multiparameter Transmitter Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Liquiline CM442 Multiparameter Transmitter
Answers from our engineering team on installation, compatibility and integration.
01How many sensors can the Liquiline CM442 connect?
A CM442 connects one or two Memosens digital sensors. More measuring channels require a hardware upgrade to the CM444 or CM448 platform.
02What is Memosens technology?
Memosens is a non-contact digital sensor technology that converts the measured value to a digital signal at the sensor, enabling optimum galvanic isolation, no contact corrosion, and a completely watertight measuring point.
03What communication protocols does the CM442 support?
The CM442 supports HART, PROFIBUS DP, Modbus RS485/RTU/TCP, EtherNet/IP, and PROFINET, plus an integrated webserver for remote access.
04Can the CM442 be used in hazardous areas?
Yes. The transmitter can be extended with a module carrying IECEx, ATEX, and CSA explosion protection approvals to allow connection of sensors installed in hazardous areas.
05Is Seven Star LLC a trusted supplier for Endress+Hauser products?
Yes. Seven Star LLC is an experienced supplier of Endress+Hauser instrumentation in Oman and the GCC, providing genuine products with full support.