Liquiline CM442 Multiparameter Transmitter
Overview
The Liquiline CM442 is Endress+Hauser’s state-of-the-art 1-/2-channel multiparameter transmitter for pH, ORP, conductivity, oxygen, chlorine, turbidity, sludge level, SAC, nitrate, and many other liquid analysis parameters. Built on the modular Liquiline platform, the CM442 allows up to 2 Memosens digital sensors of choice from over 12 measurement parameters to be connected to a single robust field transmitter.
With fast quotation turnaround and technical support, Seven Star LLC proudly offers the Liquiline CM442 to water and wastewater treatment plants, food and beverage producers, and chemical processing facilities across the Sultanate of Oman, Muscat, and the wider GCC. Its universal modules minimize spare part stock while its automatic sensor recognition and hot plug-and-play capability with pre-calibrated Memosens sensors dramatically simplify commissioning and maintenance for plant technicians managing dozens of analysis points across a treatment facility.
Measurement Principle
The Liquiline CM442 operates on Memosens digital sensor technology, which converts the measured value to a digital signal at the sensor itself and transfers it to the transmitter without a contacting connection. This non-contact, digital signal transmission enables optimum galvanic isolation, eliminates contact corrosion, and results in a completely watertight measuring point, while also supporting laboratory sensor calibration for increased measured value availability.
Memosens technology further enables predictive maintenance by recording sensor data such as total operating hours, hours of operation with high or low measured values, hours at high temperatures, and sensor condition history. Depending on the sensor connected, the CM442 supports potentiometric pH/ORP measurement, conductive and inductive conductivity measurement, amperometric dissolved oxygen measurement, four-beam alternating light turbidity measurement, and ultrasonic sludge level detection, among others.
Engineering Design of the Liquiline CM442
The Liquiline CM442 features a robust plastic housing (PC-FR base, EPDM seal) rated IP66/IP67, suitable for all non-Ex applications, with overall dimensions of 237 x 194 x 162mm. Its operating process temperature range spans -20°C to +60°C, and the transmitter accepts 1 to 2 Memosens digital inputs as standard, with optional 2x 0/4-20mA current inputs and 2x digital inputs.
Output and communication options include 2 to 8 current outputs (0/4-20mA), alarm relay, up to 2 relays, and digital fieldbus support via PROFIBUS DP, Modbus RS485/RTU, Modbus TCP, EtherNet/IP, and PROFINET, plus an integrated webserver for remote diagnostics, configuration, and parameter access from any browser, including smartphones. The modular design allows extension to up to 8 measuring channels at any time, and configuration can be saved to an SD card for fast duplicate setup across multiple installations.
Key Features
The Liquiline CM442 combines Memosens digital sensor connectivity with flexible modular expansion. Core capabilities include:
- Connects up to 2 Memosens digital sensors across 12+ measurement parameters.
- Automatic sensor recognition with hot plug-and-play, pre-calibrated Memosens sensors.
- Modular design extendable to 8 measuring channels at any time.
- IP66/IP67-rated robust plastic housing for all non-Ex applications.
- Integrated webserver for remote configuration and diagnostics via any browser.
- HART, PROFIBUS DP, Modbus RS485/RTU/TCP, EtherNet/IP, and PROFINET connectivity.
- Heartbeat Technology for status-oriented maintenance and measuring point verification.
- SD card configuration backup for rapid setup on duplicate installations.
Industrial Applications
The Liquiline CM442 is well suited to municipal water and wastewater treatment, food and beverage processing, power generation, and chemical facilities across Oman requiring reliable, expandable multiparameter liquid analysis. Its universal module concept and standardized Liquiline spare parts reduce inventory costs while its Ex-extendable design allows connection of sensors installed in hazardous areas via IECEx, ATEX, and CSA-approved modules.
With engineering support in Muscat, Seven Star LLC supports water utilities, food processing plants, and industrial facilities throughout the Sohar and Salalah economic zones and the broader GCC region with the Liquiline CM442’s proven multiparameter analysis platform.
Technical Specifications
Full technical parameters for the Liquiline CM442 multiparameter transmitter:
| Parameter | Specification |
|---|---|
| Model | Liquiline CM442 |
| Channels | 1 to 2 Memosens Digital Inputs (Extendable to 8) |
| Supported Parameters | pH, ORP, Conductivity, Oxygen, Chlorine, Turbidity, Sludge Level, SAC, Nitrate |
| Housing | PC-FR Plastic, EPDM Seal, IP66/IP67 |
| Dimensions | 237 x 194 x 162mm |
| Process Temperature | -20°C to +60°C |
| Outputs | 2 to 8x 0/4-20mA, Alarm Relay, Up to 2 Relays |
| Communication | HART, PROFIBUS DP, Modbus RS485/TCP, EtherNet/IP, PROFINET |
| Certificates | EAC, cCSAus, MCERTS |
Why Choose Seven Star LLC for Multiparameter Liquid Analysis
A Liquiline platform’s real value comes from standardizing a plant’s entire liquid-analysis fleet around one Memosens-compatible transmitter family, but that only pays off if the sensor types, channel count, and communication protocol are planned across the whole facility rather than ordered site by site. Seven Star LLC’s engineers review a customer’s full analysis-point list – pH, conductivity, dissolved oxygen, turbidity, and the rest – before quoting, so the CM442’s channel and module configuration matches actual current and near-term future needs rather than requiring a second unit later. We also help plan a shared Memosens sensor spares pool across a treatment plant’s transmitter fleet, since the sensors themselves are interchangeable across compatible Liquiline units, and we coordinate delivery and commissioning support across water and wastewater facilities in Muscat, Sohar, and the broader GCC.
Request a Quote for Liquiline CM442 Multiparameter Transmitter
To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Liquiline CM442 Multiparameter Transmitter, please contact the instrumentation division at Seven Star LLC today. Backed by genuine manufacturer documentation, our engineers are ready to assist with rapid sourcing for your liquid analysis and process monitoring projects.
Related Products
- Instruction Manual Endress+Hauser (E & H) Liquiline CM442 Multiparameter Transmitter Manual Download

Reviews
There are no reviews yet.