Brand:

Hach BioTector B3500ul Online TOC Analyzer

Description

Overview

The Hach BioTector B3500ul is an online Total Organic Carbon (TOC) analyzer purpose-built for ultra-low-level TOC monitoring in ultrapure water applications, measuring in the 0-5000 µg/L (ppb) carbon range. It uses Hach’s patented two-stage advanced oxidation process, combining UV and chemical oxidation, to reliably break down even resistant organic compounds and deliver a true, undivided TOC result rather than relying on a single-pass combustion technique that can under-report certain organic species. The B3500ul is built for continuous, unattended operation with industry-leading uptime, supporting up to two process streams plus grab sample capability from a single analyzer.

Seven Star LLC supplies the Hach BioTector B3500ul as a trusted supplier of Hach products to power stations, semiconductor plants, pharmaceutical facilities, and RO/ultrapure water systems across Oman and the GCC that require trace-level TOC monitoring for boiler feedwater purity, condensate polishing, or ultrapure water quality assurance. Our team can help configure the correct stream count, voltage, and sample conditioning accessories for your specific water quality program before the analyzer ships.

Measurement and Operating Principle

The BioTector B3500ul draws a sample into a reaction chamber where it undergoes a two-stage advanced oxidation process: an initial ambient-temperature reaction stage followed by a second stage under elevated temperature and pressure, ensuring complete oxidation of both easily-oxidized and refractory organic compounds. Carbon dioxide released by the oxidation reaction is measured by non-dispersive infrared (NDIR) detection, and the analyzer reports TOC (or TIC, TC, and VOC, with COD/BOD correlation available) as micrograms per litre of carbon, down to a lower limit of detection of roughly 10 µg/L TOC.

Because the reaction chemistry fully oxidizes the sample rather than relying on catalytic combustion, the BioTector platform is inherently resistant to interference from inorganic salts, chlorides, and other matrix components that can foul or bias combustion-based TOC analyzers over time. This design underpins the B3500ul’s certified 99.86% uptime and its stated requirement of only two short scheduled maintenance events per year, making it well suited to continuous, unattended service in critical ultrapure water loops.

Engineering Design

The Hach BioTector B3500ul is engineered around Hach’s field-proven BioTector reactor platform, with a repeatability specification of ±2% of reading or ±6 µg/L C (whichever is greater) and a response time from around five minutes depending on application and stream configuration. The analyzer supports up to two process streams plus grab sample analysis from the same reaction chamber, reducing the capital and maintenance burden of monitoring multiple ultrapure water points compared to installing separate single-stream analyzers.

Application areas documented by Hach for the B3500ul include dry steam power generation monitoring and semiconductor-grade ultrapure water quality assurance, where trace-level organic carbon directly affects turbine reliability or wafer yield. The unit is available in multiple AC voltage configurations (115 V and 230 V) and single- or dual-stream builds, allowing it to be specified precisely against the sample points and power infrastructure of the installation site.

The Hach BioTector B3500ul oxidation chemistry uses a 1.2 N sodium hydroxide base reagent and a 1.8 N sulfuric acid reagent containing 80 mg/L manganese as a catalytic aid, both delivered from bulk reagent containers sized to the analyzer’s low, predictable dosing rate per sample cycle. The analyzer accepts sample across a pH range of 1 to 12 and an inlet temperature of 2°C to 60°C, giving it tolerance for the variable feed conditions found on ultrapure water, condensate, and produced water sample points without requiring dedicated upstream pH conditioning in most applications. Accuracy is specified separately from repeatability at ±2% of reading or ±15 µg/L C, whichever is greater, with a limit of quantification of approximately 80 µg/L TOC. Housed in a floor-standing enclosure measuring 1000 mm high by 500 mm wide by 320 mm deep and weighing approximately 50 kg, the B3500ul is available with IP44 or IP54 protection depending on the cooling configuration selected, and operates across an ambient range of 5°C to 45°C and up to 85% relative humidity, non-condensing.

On the communications side, the BioTector B3500ul supports Modbus RTU, Modbus TCP/IP, and an optional Profibus interface, and retains the previous 9,999 analysis records plus 99 fault records on board, with archive export to SD/MMC card for offline review or compliance recordkeeping. Hazardous-area variants are available with ATEX Zone 1/2, Class I Division 2, or IECEx Zone 1 certification, extending the B3500ul’s applicability to classified sample points within refinery and gas processing utilities as well as conventional power and semiconductor plant rooms.

Hach BioTector B3500ul Key Features

  • Hach BioTector B3500ul measures TOC from 0-5000 µg/L C with a lower detection limit near 10 µg/L
  • Patented two-stage advanced oxidation process ensures complete, reliable oxidation of organic compounds
  • NDIR detection of CO₂ delivers accurate, undivided TOC, TIC, TC, and VOC results
  • Supports up to two process streams plus grab sample analysis from one analyzer
  • Industry-leading uptime certified at 99.86% with only two scheduled maintenance events per year
  • Repeatability of ±2% of reading or ±6 µg/L C, whichever is greater
  • Resistant to fouling and matrix interference compared to catalytic combustion TOC analyzers
  • Available in 115 V or 230 V AC configurations for single- or dual-stream installations

Industrial Applications for the Hach BioTector B3500ul

The BioTector B3500ul is applied in power generation for dry steam and boiler feedwater TOC monitoring, in petrochemical plants for demineralized water quality checks, and in semiconductor and pharmaceutical facilities for ultrapure water system verification where even trace organic carbon can compromise product quality or equipment reliability. Its ppb-level sensitivity and low maintenance burden make it a preferred choice for continuous, unattended ultrapure water TOC monitoring compared to lab-based grab sampling.

As a trusted supplier of Hach products, Seven Star LLC supports power plants, desalination facilities, and industrial water treatment operators in Muscat, Sohar, Duqm, and Salalah with the BioTector B3500ul analyzer, along with commissioning support and access to genuine Hach reagents and spare parts for ongoing operation across Oman and the GCC.

Hach BioTector B3500ul Technical Specifications

Model Hach BioTector B3500ul
Parameter Total Organic Carbon (TOC), plus TIC, TC, VOC
Measuring Range 0-5000 µg/L C
Lower Limit of Detection ∼10 µg/L TOC
Repeatability ±2% of reading or ±6 µg/L C, whichever is greater
Oxidation Method Two-stage advanced oxidation (UV + chemical)
Detection Method Non-dispersive infrared (NDIR)
Streams Up to 2 process streams plus grab sample
Power 115 V AC or 230 V AC
Uptime Certified 99.86%
Manufacturer Hach
Accuracy ±2% of reading or ±15 µg/L C, whichever is greater
Limit of Quantification ~80 µg/L TOC
Reagents 1.2 N NaOH (base); 1.8 N H2SO4 with 80 mg/L Mn (acid)
Enclosure 1000 x 500 x 320 mm, ~50 kg, IP44/IP54
Ambient Conditions 5–45°C, up to 85% RH non-condensing; sample inlet 2–60°C
Communications Modbus RTU, Modbus TCP/IP, optional Profibus
Hazardous Area Options ATEX Zone 1/2, Class I Div. 2, IECEx Zone 1

Request a Quote

Contact Seven Star LLC to request a quote for the Hach BioTector B3500ul TOC analyzer, including configuration support and delivery across Oman and the GCC.

Seven Star LLC keeps the Hach BioTector B3500ul available for fast quoting to power, semiconductor, and pharmaceutical water treatment operators across Oman requiring reliable ultrapure TOC monitoring.

Related Products

Datasheets & Documents
  • PDF Datasheet Hach BioTector B3500ul Online TOC Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Water quality testing is the single subject Hach has worked on since 1947, from the reagent pillow in a field kit to online analyzers in a treatment plant. The company is based in Loveland, Colorado. Seven Star LLC lists Hach online analyzers, controllers, sensors, portable meters and reagents, and sources them for water, wastewater, power and process plants in Oman.

Hach analyzers, sensors and reagents listed

The Hach products on this page fall into four groups:
  • Online analyzers: CL17sc colorimetric chlorine analyzer, TU5300sc and TU5400sc laser turbidimeters, BioTector B3500ul TOC analyzer, Polymetron 9245 sodium analyzer and Orbisphere 510 dissolved gas analyzer
  • Controllers and digital sensors: SC4500 controller and the LDO 2 luminescent dissolved oxygen sensor
  • Portable and laboratory instruments: 2100Q turbidimeter, HQ4200 multi-parameter meter and IntelliCAL probes such as the LBOD101
  • Reagents: DPD free chlorine powder pillows and DEHA reagents for oxygen scavenger testing
Polymetron and Orbisphere analyzers are aimed at power plant water-steam cycles and similar pure water duties, where sodium, dissolved oxygen and other gases are measured at low levels.

Where Hach instruments are used

Hach instruments appear in drinking water plants, desalination, sewage treatment, cooling and boiler water circuits, and industrial effluent monitoring across the GCC. Operators use the portable meters and reagents for spot checks, and the sc analyzers and probes for continuous signals to the control system.

Ordering Hach products: what we need

Hach identifies every item by a catalog number, for example LXV416.99.20001 for a sensor or 21055-69 for a reagent pack, and the same reagent may be written with or without the dash. Send that number and the quantity. For analyzers and controllers, add the parameter and range, sample conditions, power supply, outputs and communication option. For sensors, tell us the controller model they will connect to and the cable length. For reagents, name the instrument and method so pack size and range can be confirmed against Hach documentation.

Frequently Asked Questions

What does the Hach BioTector B3500ul measure?
It measures Total Organic Carbon (TOC), plus TIC, TC and VOC, in the 0-5000 micrograms per litre range for ultrapure water applications.
How does the two-stage oxidation process work?
The BioTector B3500ul uses an initial ambient-temperature oxidation stage followed by a second stage under elevated temperature and pressure, ensuring complete oxidation of both easily-oxidized and refractory organic compounds.
What is the detection limit of the B3500ul?
The lower limit of detection is approximately 10 micrograms per litre TOC, with repeatability of plus or minus 2% of reading or 10 micrograms per litre, whichever is greater.
How many process streams can the B3500ul monitor?
The analyzer supports up to two process streams plus grab sample analysis from a single unit.
Does Seven Star LLC supply Hach TOC analyzers in Oman?
Yes, Seven Star LLC is a trusted supplier of Hach products supplying the BioTector B3500ul and genuine reagents and spares across Oman and the GCC.