Brand:

BARTEC Salt in Crude Analyzer Model P-600

Description

Product Overview

The BARTEC P-600 Salt in Crude Analyzer is an online process analyzer that measures the amount of chloride-based salts in crude oil, expressed as weight per volume. Accurate salt measurement is essential for optimizing desalter operation and protecting refinery equipment from corrosion and fouling.

The analyzer covers a measuring range of up to 0-400 PTB (pounds per thousand barrels, equivalent to 0-1000 mg/L). It is fully automatic, uses micro samples with low solvent consumption, and features measuring cell temperature control for stable and repeatable results. The method correlates with ASTM D3230, the standard test method for salts in crude oil.

Key Features

  • Online measurement of salt content in crude oil (chloride-based salts)
  • Measuring range up to 0-400 PTB (0-1000 mg/L)
  • Correlates with ASTM D3230 salt-in-crude method
  • Micro samples with low solvent consumption
  • Measuring cell temperature control for accuracy
  • Enclosed solvent tanks for safety
  • Fully automatic operation with Modbus support and remote standby option

Technical Specifications

Model BARTEC P-600 Salt in Crude Analyzer
Measurement salt content (chloride-based salts) in crude oil, weight per volume
Range up to 0-400 PTB (0-1000 mg/L)
Method correlates with ASTM D3230
Features micro samples, low solvent consumption, cell temperature control
Communication Modbus, local interface, remote standby option
Manufacturer BARTEC (BARTEC ORB)

Applications

The P-600 is used in refineries and crude oil processing facilities to monitor salt content before and after desalting, enabling operators to use de-salters as efficiently as possible and ensuring crude quality for transport and refining.

Ordering and Selection

When ordering the BARTEC salt in crude analyzer, confirm the measuring range, sample system and communication interface, because each BARTEC salt in crude analyzer is configured for a specific refinery duty. The BARTEC P-600 salt in crude analyzer measures 0-400 PTB and correlates with ASTM D3230, and the selected salt in crude analyzer must be matched to the crude oil quality and desalter operation at your plant. Our team can help you confirm that the BARTEC salt in crude analyzer you select is correct for your application.

Maintenance and Support

The BARTEC salt in crude analyzer requires periodic maintenance including solvent and cell cleaning, and genuine spare parts are available through Seven Star LLC. Our team supports refinery analyzer teams with the full range of BARTEC salt in crude analyzer spares and accessories. Contact us for assistance with the BARTEC salt in crude analyzer, and we will confirm availability and lead time for your project

Industry Applications and Custom Support

The BARTEC salt in crude analyzer is trusted by operations and maintenance teams across refineries in Oman, the GCC and the wider Middle East region. Our customers select the BARTEC analyzer for reliability, genuine quality and dependable supply. Seven Star LLC provides custom support including technical selection, quotation and after-sales assistance, and we regularly supply this analyzer as part of preventive maintenance programs and shutdown packages. Whether you need a single unit or a complete set for a project, our team supports procurement and inspection.

The P-600 analyser measures the salt content of the crude oil with the conductivity method, and the analyser provides the online measurement for the desalter and the refinery control.

The sample system of the analyser includes the filtration and the flow control, and the measurement provides the continuous salt content for the process control.

The BARTEC analyser is installed in the crude oil processing, and the measurement covers the salt content range of the desalter outlet.

The BARTEC P-600 salt in crude analyzer measures the salt content of the crude oil online, and the BARTEC P-600 salt in crude analyzer is installed at the desalter outlet of the refinery.

Why Seven Star LLC?

Seven Star LLC supplies genuine BARTEC analyzers and spare parts to oil and gas customers in Oman and the GCC. We verify model configurations and support analyzer maintenance with reliable, fast supply.

Seven Star LLC maintains a regional inventory in Muscat and coordinates directly with manufacturers across Europe and Asia. Our engineers help you verify the exact model and revision before ordering, avoiding costly mismatches.

Also available: Bartec EXguard Mobile Gas Detection System

Request a Quote for BARTEC Salt in Crude Analyzer Model P-600

For the P-600 or any related control and instrumentation requirement, contact the Seven Star LLC team. Submit a formal inquiry through our RFQ page with your configuration and application details, and our specialists will respond with a detailed commercial proposal and the official P-600 documentation.

Specifying a P-600 for Your Desalter

A salt-in-crude analyser only helps desalter control if it sees a representative sample and its results line up with the laboratory. When preparing an enquiry, it is worth collecting:

  • the sample point (desalter inlet, outlet or both) and the expected salt range at each;
  • crude type, API gravity range, water cut and temperature at the tap;
  • area classification and whether the analyser will sit in a shelter or an existing analyser house;
  • the control system interface required, such as Modbus to the DCS, and any remote standby needs;
  • the laboratory method currently used, so correlation to ASTM D3230 results can be planned.

Installation and Commissioning

Keep the sample line from the tap to the analyser short and at a steady temperature, with a fast loop so the analyser is not measuring stale crude. Filtration and flow control in the sample system should be sized for waxy or heavy crudes where relevant. Solvent storage needs ventilation and safe access for refilling. During commissioning, run the analyser alongside laboratory samples taken at the same time and location for a period long enough to build a reliable correlation before the online value is used for control.

Operation and Maintenance

  • Monitor solvent levels and plan refills so the analyser never runs dry.
  • Clean the measuring cell and check sample filters at the intervals given in the BARTEC manual; build-up on the cell is the usual cause of creeping readings.
  • Compare analyser values with regular laboratory checks and investigate any sustained offset rather than adjusting blindly.
  • Keep a stock of consumables and wear parts, especially before planned shutdowns.

Troubleshooting Pointers

Erratic results often come from the sample rather than the analyser: free water slugs, poor mixing at the tap or blocked filters. A step change after maintenance usually points to cell condition, solvent quality or calibration. Communication faults with the DCS are best checked at the Modbus settings and wiring before replacing electronics.

Applications in Oman and the GCC

Refineries and crude processing facilities in the region handle a mix of local and imported crudes with varying salt content. Online measurement before and after the desalter helps operators adjust wash water and demulsifier dosing and protect crude unit overhead systems from chloride corrosion.

Working With Seven Star LLC

Share your process conditions and the analyser serial number if you are replacing or supporting an existing unit. We will help confirm the configuration and spare parts and provide a quotation with lead time.

Related Products

Datasheets & Documents
  • PDF Datasheet BARTEC Salt in Crude Analyzer Model P-600 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Explosion protection is the common thread in everything BARTEC makes. The company was founded in 1975 and is based in Bad Mergentheim, Germany, and its equipment is built to work safely where flammable gas or dust may be present. Seven Star LLC lists BARTEC process analyzers, Ex enclosures, switching components and hazardous-area tablets, and supplies them to refineries, gas plants and panel builders in Oman by type number.

BARTEC product families on this page

The analyzer group is the largest. Under the HYGROPHIL name there are the HYGROPHIL F 5674 process trace moisture analyzer and the Hygrophil HCDT hydrocarbon dew-point analyzer. Under the BARTEC BENKE name there are the RVP-4 vapor pressure process analyzer and the P-600 salt in crude analyzer. The electrical side is represented by the GUB flameproof Ex d IIC enclosure and the 07-1511 series insert switch, a component used inside control stations. The Agile X IS is a tablet PC for Zone 1, and the EXguard is a mobile gas detection system for hot work.

Where BARTEC equipment is used

Moisture and hydrocarbon dew-point analyzers monitor natural gas at dehydration units, pipeline entry points and custody stations. Vapor pressure and salt in crude analyzers serve refinery blending and crude treatment. Flameproof enclosures and Ex switches go into local control stations, junction boxes and motor starters. Ex tablets are used for inspection rounds and work permits on GCC oil and gas sites.

Ordering BARTEC parts: what we need

BARTEC identifies products by a type number, such as 07-1511-154D/02 or 5674-xx. Send that number in full with the serial number from the label. For analyzers we also need the gas or liquid composition, pressure and temperature at the sample point, the measuring span, the area classification and the signal outputs. For enclosures give the size, the required gas group and temperature class, and the cable entry schedule.

Frequently Asked Questions

What does the BARTEC P-600 measure?
It measures the amount of chloride-based salts in crude oil, expressed as weight per volume.
What is the measuring range of the P-600?
The range is up to 0-400 PTB, equivalent to 0-1000 mg/L.
Which standard does the analyzer correlate with?
The method correlates with ASTM D3230 for salts in crude oil.
Can the analyzer communicate with plant systems?
Yes, it supports Modbus and provides a local interface with remote standby option.
What details should I include in my inquiry for the BARTEC P-600 salt in crude analyzer?
Send the part number, your system details and the required quantity through the RFQ page. Seven Star LLC confirms the exact configuration, the matching accessories and the commercial terms for your project.