The JUMO TYA S202 (type 709066) is a thyristor power controller for resistive and resistive-inductive loads in a three-phase economy circuit. It uses a master and slave pair of units, where the master carries the display and keys and configures the slave over a 1:1 patch cable. The load is controlled by pulse groups, with a soft start to avoid high inrush currents and optional base load. For transformer loads, the phase angle of the first half-wave can be cut to reduce inrush current. The datasheet names industrial furnace construction and plastics processing as typical uses. Each controller has anti-parallel thyristors, an insulated heat sink, control electronics and a semiconductor fuse, and load currents run from 20 A to 250 A for AC 400, 460 or 500 V mains.

Technical specifications

Parameter Specification
Type 709066 TYA S202, three-phase economy circuit, master and slave
Load current 20, 32, 50, 100, 150, 200 and 250 A rms
Mains voltage AC 400 V, 460 V or 500 V (-20 %/+15 %), 48 to 63 Hz
Load type Resistive and resistive-inductive; transformer loads up to nominal induction 1.2 tesla
Operating mode Burst-firing with soft start; dual energy management
Control signal 0(4) to 20 mA (50 Ω); 0(2) to 10 V and 0(1) to 5 V (25 kΩ); or via interface
Logic mode Acts as solid state relay, switching threshold at middle of input range, e.g. 12 mA or 5 V
Interfaces USB setup; RS422/485 Modbus or PROFINET
Fault relay Changeover, 30,000 operations at AC 230 V 3 A (1.5 A UL)
Control power Up to 40 VA; fan AC 230 V 2 x 30 VA only at 250 A
Monitoring Partial load failure, load short-circuit, rotating field detection, semiconductor fuse LED
Display LCD 96 x 64 pixels with white backlight, four keys, plain text in national languages
Housing Plastic UL94 V0, cobalt blue RAL 5013; IP20; protection class I
Mounting Up to 50 A on 35 mm DIN rail or wall plate; above 50 A wall only; close mounting without spacing
Cooling Natural convection up to 200 A; fan at 250 A; clearance 10 cm below and 15 cm above
Ambient temperature 0 to 45 °C self-cooled (0 to 40 °C with fan); derating 2 %/°C above 45 °C; altitude derating 0.86 %/100 m above 1000 m
Weight About 2.2 kg (20 A) up to 20.4 kg (250 A)
Approvals UL 508 (E223137), EAC; EMC DIN 61326 class B; DIN EN 50178

Selecting the rating and the circuit

Select the load current from the heater rating, with the power loss estimated by the empirical formula Pv = 2 x (20 W + 1.3 V x load current in A), which also sizes the cabinet ventilation. The maximum heat sink temperature is 110 °C, the current reduces above 105 °C and the controller switches off above 115 °C. Natural convection serves up to 200 A. At altitude the ampacity falls, and the datasheet gives 91.4 % at 2000 m. The economy circuit uses two controlled phases, so check that the three-phase heater suits this connection. The version with a PROFINET or RS422/485 interface suits integration with a PLC.

Installation and application notes

Mount vertically and connect the supply and load as shown in the type-specific diagram. Devices from 32 A use cable lugs on the load leads, and tightening torques range from 0.25 Nm for signal terminals to 12 Nm for the M8 load screws on 150 A and above. The device must be grounded and is built in for pollution degree 2 and overvoltage category III. Typical Gulf uses are electric heaters in process skids, heat-treatment ovens, extruders and plastic processing, where a burst-firing controller keeps harmonics low compared with phase-angle control. For fast-reacting loads or non-linear loads, other TYA types are the better fit.

See the power modules category for related items.

The display shows mains voltage with ±2.5 % accuracy and load current and load voltage with ±1 %, and the analog input is read with a 12-bit converter. Galvanic isolation separates the control circuits from the power section, with AC 3800 V between load connection and the electronics and AC 350 V between the interfaces and the analog inputs, and creepage distances are 8 mm on the 20 A type and 12.7 mm from 32 A. Master and slave are plugged together by default, so only the supply voltage and the load must be wired and parameterised on site.

Using the TYA S202 in Oman and the GCC

Three-phase thyristor controllers are used in the region for electric heaters in plastics processing, heat treatment furnaces, drying ovens, process water heaters and trace heating systems. Burst firing suits resistive heaters well and keeps harmonic distortion lower than phase angle control. The economy circuit with two controlled phases saves cost and panel space for balanced three-phase loads.

Thyristor controllers create heat, and panel temperature is often the limiting factor in summer. Size the panel ventilation or air conditioning for the heat loss of the controllers, keep the heat sinks clear of dust, and follow the derating curves in the operating manual. Semiconductor fuses must be used as specified to protect the thyristors.

Before ordering, compare the controller rating with the real load current, including the increase in heater current when elements are cold, and leave a margin. Where several heater zones run from one panel, the total heat loss of all thyristor units must be considered together when sizing the panel cooling.

Information to send with an enquiry

  • Load type, power and supply voltage
  • Load current per phase
  • Control signal from the temperature controller
  • Panel conditions and ambient temperature
  • Quantity

Related JUMO products: JUMO TYA 203 Three-Phase Thyristor Power Controller, JUMO TYA 201 Single-Phase Thyristor Power Controller and JUMO TYA HL301 Single-Phase Thyristor Controller, Type 709081.

Documents and quotation

The hosted document is JUMO data sheet 709066 (17 pages, English). It includes dimensions for each rating, wiring and order codes. Confirm current, mains voltage, interface and options before ordering. Seven Star LLC is an independent supplier in Muscat; send the heater data and control signal for a quotation. To help us prepare an accurate quotation, please include the load, supply voltage, required output signal, mounting situation and ambient temperature, together with the quantity needed and the delivery location. We will then compare these details with the order information in the datasheet.

Datasheets & Documents
  • PDF Datasheet JUMO 709066 data sheet 709066 (EN) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.

Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.

JUMO company profile

Established 1948, Fulda, Germany, by Moritz Kurt Juchheim
First products Glass and contact thermometers; platinum glass sensors from 1966
Ownership Family-owned; renamed JUMO GmbH & Co. KG in 2003
Product families RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments

Milestones

  • 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
  • 1966: Platinum glass temperature sensors are added.
  • 2003: The parent company is renamed JUMO GmbH & Co. KG.

JUMO products we list

Family Models Typical use
RTD and thermocouple probes 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp Temperature measurement in pipes, vessels, machines, HVAC and food plants
Thermowells and inserts 909710 thermowells, 909740 measuring inserts Protecting sensors and replacing them without opening the process
Temperature transmitters dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch Converting sensor signals to 4-20 mA, HART or IO-Link
Pressure and level dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 Pressure in process, hydraulic and OEM systems; tank and well level
Controllers, limiters and recorders DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T Furnace, oven and process control, over-temperature protection and recording
Liquid analysis and flow AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 pH, conductivity, oxygen and turbidity in water treatment; liquid flow

Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.

Where JUMO products are used

In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.

Ordering JUMO products: what we need

Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.

Facts checked against JUMO's company history, October 2026.

FAQ

Questions about the JUMO TYA S202 Three-Phase Thyristor Power

Answers from our engineering team on installation, compatibility and integration.

01What load types suit the TYA S202?
Resistive and resistive-inductive loads in a three-phase economy circuit, including transformer loads with soft start.
02Which current ratings are available?
20, 32, 50, 100, 150, 200 and 250 A.
03How is the load controlled?
By burst firing with pulse groups, with soft start and optional base load.
04Which interfaces does it have?
USB for setup, plus RS422/485 Modbus or PROFINET.
05Does it protect itself?
A semiconductor fuse is fitted, and the controller detects partial load failure, load short-circuit and rotating field faults.