Endress+Hauser Liquiline M CM42 Multichannel Transmitter

Description

Overview

The Endress+Hauser Liquiline M CM42 is a modular two-wire transmitter designed for reliable liquid analysis measurement across the full range of process engineering applications. Supporting both analog sensors for pH, ORP, conductivity, concentration, and resistivity measurement, and digital Memosens sensors for pH, ORP, dissolved oxygen, and conductivity, the CM42 gives process engineers a flexible, future-proof platform for critical liquid analysis points, including installations in hazardous areas requiring Ex approval.

For water treatment, chemical processing, and utility operators across Oman and the wider GCC, the Liquiline M CM42 provides dependable analytical measurement with safe galvanic isolation between the supply and sensor circuit, developed in accordance with the international functional safety standard IEC 61508. Seven Star LLC supplies the Endress+Hauser Liquiline M CM42 multichannel transmitter to customers across Muscat, Sohar, Salalah, and the Sultanate of Oman as a trusted supplier of Endress+Hauser products, providing instruments with manufacturer documentation and technical support.

Measurement and Operating Principle

The CM42 processes signals from a single connected sensor – either a traditional analog probe or a digital Memosens sensor – and converts the measured process value into a standardized output signal for transmission to the control system. When paired with Memosens digital sensor technology, the transmitter benefits from inductive, contact-free signal transmission between sensor and transmitter, virtually eliminating the measurement errors caused by moisture ingress or corrosion at the sensor connection that commonly affect conventional analog installations.

Output signal options include one or two 4…20 mA current loops, HART digital communication superimposed on the analog signal, PROFIBUS PA, and FOUNDATION Fieldbus, giving system integrators significant flexibility when specifying the transmitter into new or existing control architectures. The transmitter’s compact, modular electronics platform is shared across the wider Liquiline family, simplifying spares holding and technician familiarity across a plant’s full complement of liquid analysis instrumentation.

Engineering Design of the Endress+Hauser Liquiline M CM42

The CM42 is available in a plastic housing (144 x 144 x 148 mm) or a stainless steel housing (174 x 174 x 134 mm), both fitted with EPDM sealing and rated to IP66/67 and NEMA 4X for reliable operation in washdown and outdoor environments. The transmitter operates across an ambient temperature range of −29°C to +79°C, and versions are available with Ex approval for installation in hazardous areas classified for flammable gas or dust atmospheres, an important consideration for oil, gas, and petrochemical liquid analysis points.

Configuration and calibration are performed through the transmitter’s onboard menu system, with the option to store multiple calibration data sets for straightforward sensor exchange without recalibration. The Liquiline M CM42 forms part of Endress+Hauser’s broader Liquiline transmitter family, allowing plants standardizing on Endress+Hauser liquid analysis instrumentation to maintain consistent operating procedures, spare parts, and technician training across single-channel, multi-channel, and Ex-approved variants.

Key Features

  • Supports both analog and digital Memosens sensors for pH, ORP, conductivity, and dissolved oxygen
  • Safe galvanic isolation between supply and sensor circuit, developed to IEC 61508
  • Ex-approved versions available for hazardous area installations
  • Output options: 1/2 x 4…20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
  • IP66/67, NEMA 4X protection rating for washdown and outdoor duty
  • Plastic or stainless steel housing options
  • Ambient temperature range −29°C to +79°C
  • Shared Liquiline platform simplifies plant-wide spares and training

Industrial Applications

The Liquiline M CM42 is widely deployed across water and wastewater treatment plants, chemical processing facilities, power generation, and oil and gas installations for continuous pH, ORP, conductivity, and dissolved oxygen monitoring. Its Ex-approved variants make it a preferred choice for liquid analysis points located in classified hazardous areas, such as tank farms, effluent treatment units, and process areas within petrochemical and refining facilities.

Across Oman’s water treatment and industrial sectors, including facilities supporting the Sohar and Salalah economic zones, the CM42 gives plant engineers a proven, standardized transmitter platform for critical liquid analysis measurement points. As a trusted supplier of Endress+Hauser products, Seven Star LLC supports these projects throughout the Sultanate of Oman with instrumentation supplied on request, sensor pairing guidance, and ongoing technical support.

Technical Specifications

Model Endress+Hauser Liquiline M CM42
Type 1-channel modular two-wire transmitter
Measured Parameters pH, ORP, conductivity, dissolved oxygen, concentration, resistivity
Sensor Compatibility Analog and digital Memosens sensors
Output 1/2 x 4…20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
Protection Rating IP66/67, NEMA 4X
Ambient Temperature −29°C to +79°C
Housing Options Plastic (144x144x148 mm), Stainless steel (174x174x134 mm)
Functional Safety Developed to IEC 61508, Ex-approved versions available
Manufacturer Endress+Hauser

Why Choose Seven Star LLC for Endress+Hauser Multichannel Analyzer Transmitters

A multichannel liquid analysis transmitter only delivers reliable process control when its sensor inputs, measurement ranges, and functional safety configuration genuinely match the parameters your process actually needs to monitor, whether that is pH, conductivity, dissolved oxygen, or a combination requiring careful channel allocation. Seven Star LLC works with your process control engineers to confirm the correct Liquiline M CM42 channel configuration and sensor compatibility for your application before order confirmation, drawing on our trusted Endress+Hauser suppliership across Oman and the wider GCC. We also support water treatment and process facilities across Muscat, Sohar, and Salalah with sensor calibration scheduling and IEC 61508 safety-loop documentation, keeping liquid analysis instrumentation defensible for both process control and safety-instrumented applications.

Order Your Endress+Hauser Liquiline M CM42 Today

Contact Seven Star LLC to request a quotation, datasheet, or technical consultation for the Endress+Hauser Liquiline M CM42 multichannel transmitter. As a trusted Endress+Hauser supplier serving Muscat, Sohar, Salalah, and the greater Sultanate of Oman, Seven Star LLC supplies instrumentation on request with manufacturer documentation and dedicated technical support for liquid analysis projects across the GCC.

Related Products

Also available: Endress+Hauser COM223-DX0005 Liquisys Dissolved Oxygen Transmitter

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Liquiline M CM42 Multichannel Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Level, flow and pressure measurement account for most of the Endress+Hauser instruments engineers ask us about, and each device is defined by the order code on its nameplate. Endress+Hauser, founded in 1953 and based in Reinach, Switzerland, builds process instrumentation for liquids, gases and bulk solids. Seven Star LLC is an independent supplier listing Endress+Hauser (E+H) flowmeters, radar and vibronic level instruments, pressure and temperature transmitters and liquid analysis equipment for plants in Oman and the GCC.

Endress+Hauser product families on this page

Level is the largest group: Micropilot free-space radar (FMR10B, FMR62 and the FMR67 for bulk solids, all 80 GHz), Levelflex guided radar (FMP50, and the FMP55 for interface measurement), the Liquiphant FTL51 vibronic point level switch and the Prosonic S FMU90 ultrasonic transmitter. Flow covers Proline Promag electromagnetic flowmeters (Promag P 300, Promag W 400) and the Prowirl F 200 vortex meter. Pressure is represented by the Cerabar PMP51B, temperature by the iTEMP TMT82 HART transmitter. For liquid analysis the listing has the Liquiline CM444 multiparameter transmitter and Memosens sensors such as the CPS11E pH electrode.

Where Endress+Hauser instruments are used

Water and wastewater plants rely on Promag W meters, radar level and Liquiline analysis. Oil and gas, chemical and power plants specify Levelflex and Micropilot on tanks and separators, Prowirl on steam and gas, and Cerabar on process lines. Food and pharmaceutical producers use hygienic versions of the same families, and cement and mining sites use the FMR67 on silos.

Ordering Endress+Hauser instruments: what we need

Send the order code and, for a replacement, the serial number from the nameplate. The extended order code is better still, because it spells out every option. Without a code we need the medium, pressure and temperature, measuring span, process connection, wetted materials, output signal or fieldbus, power supply, display and the hazardous area approval required. For flowmeters add line size and liner, for radar the tank height and nozzle size.

Frequently Asked Questions

What parameters can the Liquiline M CM42 measure?
The CM42 measures pH, ORP, conductivity, dissolved oxygen, concentration, and resistivity, depending on the connected analog or digital Memosens sensor.
Does the CM42 support digital Memosens sensors?
Yes. The CM42 supports both traditional analog sensors and digital Memosens sensors, which use inductive, contact-free signal transmission to reduce measurement errors from moisture and corrosion.
Is the Liquiline M CM42 available for hazardous areas?
Yes. Ex-approved versions of the CM42 are available for installation in classified hazardous areas, making it suitable for oil, gas, and petrochemical liquid analysis points.
What output signals does the CM42 support?
The CM42 supports one or two 4-20 mA outputs, HART communication, PROFIBUS PA, and FOUNDATION Fieldbus, depending on the ordered configuration.
Is Seven Star LLC a trusted Endress+Hauser supplier in Oman?
Yes. Seven Star LLC is a trusted Endress+Hauser distribution supplier supplying instrumentation across Muscat, Sohar, Salalah, and the wider Sultanate of Oman.