Endress+Hauser Liquiline M CM42 Single-Channel Transmitter

Description

Overview

The Endress+Hauser Liquiline M CM42 is a modular two-wire transmitter designed for reliable liquid analysis measurement across the full range of process engineering applications. Supporting both analog sensors for pH, ORP, conductivity, concentration, and resistivity measurement, and digital Memosens sensors for pH, ORP, dissolved oxygen, and conductivity, the CM42 gives process engineers a flexible, future-proof platform for critical liquid analysis points, including installations in hazardous areas requiring Ex approval.

For water treatment, chemical processing, and utility operators across Oman and the wider GCC, the Liquiline M CM42 provides dependable analytical measurement with safe galvanic isolation between the supply and sensor circuit, developed in accordance with the international functional safety standard IEC 61508. Seven Star LLC supplies the Endress+Hauser Liquiline M CM42 single-channel transmitter to customers across Muscat, Sohar, Salalah, and the Sultanate of Oman as a trusted supplier of Endress+Hauser products, providing instruments with manufacturer documentation and technical support.

Measurement and Operating Principle

The CM42 processes signals from a single connected sensor – either a traditional analog probe or a digital Memosens sensor – and converts the measured process value into a standardized output signal for transmission to the control system. When paired with Memosens digital sensor technology, the transmitter benefits from inductive, contact-free signal transmission between sensor and transmitter, virtually eliminating the measurement errors caused by moisture ingress or corrosion at the sensor connection that commonly affect conventional analog installations.

Output signal options include one or two 4…20 mA current loops, HART digital communication superimposed on the analog signal, PROFIBUS PA, and FOUNDATION Fieldbus, giving system integrators significant flexibility when specifying the transmitter into new or existing control architectures. The transmitter’s compact, modular electronics platform is shared across the wider Liquiline family, simplifying spares holding and technician familiarity across a plant’s full complement of liquid analysis instrumentation.

Engineering Design of the Endress+Hauser Liquiline M CM42

The CM42 is available in a plastic housing (144 x 144 x 148 mm) or a stainless steel housing (174 x 174 x 134 mm), both fitted with EPDM sealing and rated to IP66/67 and NEMA 4X for reliable operation in washdown and outdoor environments. The transmitter operates across an ambient temperature range of −29°C to +79°C, and versions are available with Ex approval for installation in hazardous areas classified for flammable gas or dust atmospheres, an important consideration for oil, gas, and petrochemical liquid analysis points.

Configuration and calibration are performed through the transmitter’s onboard menu system, with the option to store multiple calibration data sets for straightforward sensor exchange without recalibration. The Liquiline M CM42 forms part of Endress+Hauser’s broader Liquiline transmitter family, allowing plants standardizing on Endress+Hauser liquid analysis instrumentation to maintain consistent operating procedures, spare parts, and technician training across single-channel, multi-channel, and Ex-approved variants.

Key Features

  • Supports both analog and digital Memosens sensors for pH, ORP, conductivity, and dissolved oxygen
  • Safe galvanic isolation between supply and sensor circuit, developed to IEC 61508
  • Ex-approved versions available for hazardous area installations
  • Output options: 1/2 x 4…20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
  • IP66/67, NEMA 4X protection rating for washdown and outdoor duty
  • Plastic or stainless steel housing options
  • Ambient temperature range −29°C to +79°C
  • Shared Liquiline platform simplifies plant-wide spares and training

Industrial Applications

The Liquiline M CM42 is widely deployed across water and wastewater treatment plants, chemical processing facilities, power generation, and oil and gas installations for continuous pH, ORP, conductivity, and dissolved oxygen monitoring. Its Ex-approved variants make it a preferred choice for liquid analysis points located in classified hazardous areas, such as tank farms, effluent treatment units, and process areas within petrochemical and refining facilities.

Across Oman’s water treatment and industrial sectors, including facilities supporting the Sohar and Salalah economic zones, the CM42 gives plant engineers a proven, standardized transmitter platform for critical liquid analysis measurement points. As a trusted supplier of Endress+Hauser products, Seven Star LLC supports these projects throughout the Sultanate of Oman with instrumentation supplied on request, sensor pairing guidance, and ongoing technical support.

Technical Specifications

Model Endress+Hauser Liquiline M CM42
Type 1-channel modular two-wire transmitter
Measured Parameters pH, ORP, conductivity, dissolved oxygen, concentration, resistivity
Sensor Compatibility Analog and digital Memosens sensors
Output 1/2 x 4…20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
Protection Rating IP66/67, NEMA 4X
Ambient Temperature −29°C to +79°C
Housing Options Plastic (144x144x148 mm), Stainless steel (174x174x134 mm)
Functional Safety Developed to IEC 61508, Ex-approved versions available
Manufacturer Endress+Hauser

Matching the CM42 to an existing sensor

The CM42 takes one sensor input. Specify the measurement and whether the sensor is analog or Memosens, then match the transmitter output to the control system. A second current output is an ordering option and does not add a sensor channel.

CM42 manufacturer technical reference

Order Your Endress+Hauser Liquiline M CM42 Today

Contact Seven Star LLC to request a quotation, datasheet, or technical consultation for the Endress+Hauser Liquiline M CM42 single-channel transmitter. As a trusted Endress+Hauser supplier serving Muscat, Sohar, Salalah, and the greater Sultanate of Oman, Seven Star LLC supplies instrumentation on request with manufacturer documentation and dedicated technical support for liquid analysis projects across the GCC.

Related Products

Also available: Endress+Hauser COM223-DX0005 Liquisys Dissolved Oxygen Transmitter

Datasheets & Documents
  • PDF Datasheet Endress+Hauser Liquiline M CM42 Multichannel Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser Liquiline M CM42 Single-Channel

Answers from our engineering team on installation, compatibility and integration.

01What parameters can the Liquiline M CM42 measure?
The CM42 measures pH, ORP, conductivity, dissolved oxygen, concentration, and resistivity, depending on the connected analog or digital Memosens sensor.
02Does the CM42 support digital Memosens sensors?
Yes. The CM42 supports both traditional analog sensors and digital Memosens sensors, which use inductive, contact-free signal transmission to reduce measurement errors from moisture and corrosion.
03Is the Liquiline M CM42 available for hazardous areas?
Yes. Ex-approved versions of the CM42 are available for installation in classified hazardous areas, making it suitable for oil, gas, and petrochemical liquid analysis points.
04What output signals does the CM42 support?
The CM42 supports one or two 4-20 mA outputs, HART communication, PROFIBUS PA, and FOUNDATION Fieldbus, depending on the ordered configuration.
05Is Seven Star LLC a trusted Endress+Hauser supplier in Oman?
Yes. Seven Star LLC is a trusted Endress+Hauser distribution supplier supplying instrumentation across Muscat, Sohar, Salalah, and the wider Sultanate of Oman.