Brand: Rosemount
Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna
Description
Rosemount TGU 65 Tank Radar Gauge with still pipe antenna for marine tanks
The Rosemount TGU 65 is a marine radar level gauge that fits inside a still pipe of 5 or 6 inches. It forms part of the Rosemount Cargo Monitoring System and is built for tankers and offshore installations, where tanks are narrow, decks are exposed and deposits can form. It works with 10 GHz FMCW radar and is intrinsically safe.
Seven Star LLC supplies the Rosemount TGU 65 in Oman and the GCC as an independent supplier in Muscat. The gauge exists in two versions, TGU 65C and TGU 65S, so please say which one your project needs.
TGU 65C and TGU 65S: the two versions
| Item | TGU 65C | TGU 65S |
|---|---|---|
| Intended use | Ullage in narrow slop and residual tanks on tankers and marine applications | Offshore narrow tanks and sea water draft applications |
| Measuring range | 0 to 35 m | 0 to 35 m, extended up to 65 m with option |
| Housing flange | JIS 200A / EN DN200; EN DN250 | JIS 200A / EN DN200; EN DN250; ASME B16.5 8 in. |
| Hazardous location certification | ATEX and IECEx intrinsic safety | ATEX, IECEx and INMETRO intrinsic safety |
| Cable glands | M20, M25, M32 (1-3 glands) | M20, M25, M32 and special (1-3 glands) |
| Extra options | Protective hose, bolt kit, gasket | Same plus tag plate, calibration certificate, EN 10204 3.1 material traceability and extended range |
Rosemount TGU 65 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Rosemount (Emerson) / TGU 65 |
| Antenna type | Array antenna for installation in a still pipe |
| Measuring range | 0 to 35 m standard; up to 65 m for TGU 65S |
| Instrument accuracy | ±2 mm (±3σ conformance); typical operational accuracy in still pipe ±10 mm |
| FMCW centre frequency | 10 GHz |
| Tank temperature | -40 to +100 °C |
| Tank pressure | -100 to +500 mbar |
| Still pipe inner diameter | 5 in. antenna: 124.5 to 134.5 mm; 6 in. antenna: 150.3 to 161.5 mm |
| Still pipe end | Maximum 250 mm from tank bottom; minimum 900 mm of pipe above deck at the deck socket |
| Cable to control room | Up to three cables with two or three twisted pairs and common shield, about 400 m maximum |
| Weight | 17 kg (35 lb) |
| Wetted and deck materials | Stainless steel 316L, PTFE, fluorosilicone (standard); deck side 316L |
| Ingress protection / ambient | IP66/67; -40 to +70 °C; 0 to 100% relative humidity |
| Optional vapor pressure sensor | -100 to 900 mbar, ±3 mbar, 316L and Alloy C276 |
| Approvals | Marine: ABS, BV, CCS, DNV-GL, KR, LR, NK, RINA. Intrinsic safety: ATEX II 1G Ex ia IIC T4 Ga, IECEx and INMETRO Ex ia IIC T4 Ga |
Why the TGU 65 uses a low-loss mode in the still pipe
Radar waves in a still pipe travel in a special polarised, low-loss mode. This makes the TGU 65 much less sensitive to build-up and contamination on the pipe wall, which is the weakness of many still pipe gauges on crude and product tankers. Even so, the datasheet stresses that the inside of the pipe must be smooth and free of irregularities for the best result.
The principle is FMCW: the gauge emits a continuous sweep of frequencies, mixes the returned echo with the outgoing signal and obtains a low-frequency signal proportional to the distance to the liquid. Only the antenna is inside the tank and there are no moving parts, and the tank gauge electronics can be serviced and replaced while the tank is closed.
Still pipe and installation requirements for the TGU 65
- The still pipe and deck socket are normally yard supplied. The pipe must be vented to equalise liquid level with the tank.
- The pipe can be made from flanged segments joined by bolts, butt-welded segments, or segments welded with a sleeve. It is metallic, typically stainless or carbon steel.
- For tank ullage the pipe ends over the bottom of the tank; for draft measurement it enters the sea water through a yard-supplied sea valve.
- The housing flange suits JIS 5K-200, DN200, DN250 and, on the S version, ASME 8 in.
Where the TGU 65 fits in the Rosemount system and related parts
Each measuring channel has one digital bus connection to a Rosemount SCU 51 Supply and Communication Unit. Optional bus connections go to Rosemount TMU 51/53 temperature measuring units and the TGD 51 tank gauge display. The gauge is prepared for a second channel, either as redundant level or as an independent high-level or overfill alarm, and the order list offers one or two channels. For larger open tanks, the Rosemount TGU 68 with a parabolic antenna is the alternative, and for LNG tanks the Rosemount TGU 53 is used.
Selection checklist for the TGU 65
- Choose 65C or 65S according to the project and the options needed.
- Confirm the still pipe size (5 in. or 6 in.) and whether the pipe will be yard supplied.
- Choose one or two measuring channels, plus the vapor pressure sensor and test valve if required.
- Check the housing flange and the cable gland size.
- State the required explosion protection (ATEX/IECEx or INMETRO) and marine class approval.
- For the S version, decide on extended range, tag plate and certificates.
Installation, commissioning and maintenance of the TGU 65
Check the pipe bore and venting before fitting the gauge, then mount the housing on its flange with the fluorosilicone O-ring and route cables through the glands, using the correct size for each cable. Commission the channel through the SCU 51 and the cargo software, entering tank height and reference. Keep the antenna clean and examine the pipe interior at scheduled tank entries. The optional vapor pressure sensor test valve lets the sensor be tested and replaced without breaking tank integrity.
Seven Star LLC can quote spare parts if you send the gauge serial number and the original order details.
Typical applications of the TGU 65 in Oman and the GCC
Typical use is in slop tanks, residual tanks and sea water draft measurements aboard tankers, and on offshore platforms and floating units where narrow tanks leave no room for a larger antenna. The IP66/67 enclosure and -40 to +70 °C ambient rating cope with the heat and humidity of the Arabian Gulf and Sea of Oman, and shipyards and marine service providers in the region can use the gauge for repair, retrofit and new-build programmes.
Information to send with an RFQ for the TGU 65
- Version (TGU 65C or TGU 65S) and number of channels
- Tank type, height and still pipe diameter
- Flange standard and size
- Explosion protection and class society
- Options: vapor pressure, test valve, hose, certificates
- Quantity and delivery location
Documents and quotation
A manufacturer datasheet for the Rosemount TGU 65 is attached on this page, so you can check the model code, ratings and dimensions against your project documents before ordering.
To receive a quotation, send us the part number or the full model code from your nameplate, the quantity, and the delivery location. Seven Star LLC is an independent supplier in Muscat and replies with availability and lead time, and we confirm the details with you before anything is ordered.
Other Models in the Rosemount Marine Tgu Range
Seven Star LLC supplies models from the Rosemount Marine Tgu range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount TGU 53 Tank Radar Gauge for LNG | Level Instrumentation | View details |
| Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna | Level Instrumentation | You are viewing this model |
| Rosemount TGU 68 Tank Radar Gauge, Parabolic Antenna | Level Instrumentation | View details |
Datasheets & Documents
- Datasheet Rosemount TGU 65 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount TGU 65 Tank Radar Gauge, Still Pipe
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between the TGU 65C and TGU 65S?
The 65C targets ullage in narrow slop and residual tanks on tankers. The 65S is for offshore use and adds ASME 8 in. flange, INMETRO certification, certificates and an extended range up to 65 m.
02What accuracy does the Rosemount TGU 65 have?
Instrument accuracy is ±2 mm (±3σ conformance). Typical operational accuracy in a still pipe is ±10 mm, and accuracy is undefined below the end of the still pipe.
03Which still pipe sizes does the TGU 65 fit?
It fits 5 in. (DN125) and 6 in. (DN150) pipes. Inner diameters are 124.5 to 134.5 mm for the 5 in. antenna and 150.3 to 161.5 mm for the 6 in. antenna.
04Can the TGU 65 be used for redundancy or overfill alarm?
It is prepared for a second measuring channel as redundant level or as independent high-level or overfill measurement. The order list offers one or two channels.
05What operating limits apply to the TGU 65?
Tank temperature is -40 to +100 °C and tank pressure is -100 to +500 mbar. Ambient range is -40 to +70 °C with IP66/67 protection.


















Reviews
There are no reviews yet.