Rosemount 3144P Temperature Transmitter
Description
Overview
The Rosemount 3144P Temperature Transmitter provides superior accuracy, stability, and reliability, making it the industry-leading temperature transmitter used in critical control and safety applications. Available with either 4-20mA/HART or completely digital FOUNDATION Fieldbus protocol, the 3144P accepts either single-sensor or dual-sensor inputs, with dual-sensor capability enabling differential temperature measurement, averaging temperature, or redundant temperature measurement from two independent sensors.
Backed by manufacturer datasheet documentation, Seven Star LLC proudly offers the Rosemount 3144P to oil and gas, petrochemical, pharmaceutical, and utility facilities across the Sultanate of Oman, Muscat, and the wider GCC. The HART version of the 3144P is approved for use in Safety Instrumented Systems, with third-party validated metrics tested per IEC 61508, giving safety engineers confidence in critical temperature monitoring loops where an undetected sensor failure could otherwise go unnoticed until the next scheduled proof test.
Measurement Principle
The Rosemount 3144P can be configured for a variety of sensor inputs, including RTD, thermocouple, millivolt, or ohm, with support for 2-, 3-, and 4-wire RTD configurations. Accuracy reaches ±0.18°F for Pt100 RTD inputs, delivered through 3 analog inputs and 1 input selector, with a 9.0 to 32VDC supply drawing a maximum of 11mA.
The Transmitter-Sensor Matching feature eliminates interchangeability error, improving accuracy by 75% by trimming the transmitter to the specific sensor’s Callendar-Van Dusen calibration constants. Sensor Drift Alert continuously monitors the differential temperature between two sensors; when one sensor drifts and the differential exceeds defined limits, the user is alerted to an unreliable measurement before it affects process control.
Engineering Design of the Rosemount 3144P
The Rosemount 3144P features a dual-compartment housing that isolates the electronics and terminal compartments, protecting sensitive electronics from field wiring disturbances. The Hot Backup feature reduces the risk of losing important temperature measurements by 80%, automatically switching the measurement to a backup sensor if the primary sensor fails—a critical safeguard for continuous process control loops.
Meeting NAMUR NE 21 recommendations, the 3144P ensures top transmitter performance in harsh EMC environments, while the HART version additionally meets NAMUR NE 43 and NE 89 recommendations. High-performance diagnostics available with both HART and FOUNDATION Fieldbus communication provide continuous measurement status (good, bad, or uncertain) and sensor failure indication, with performance information available to AMS asset management software, letting instrument technicians triage a drifting sensor from the control room rather than dispatching a field visit first.
Key Features
The Rosemount 3144P combines dual-sensor flexibility with industry-leading accuracy and diagnostics. Core capabilities include:
- Single- or dual-sensor input supporting RTD, thermocouple, millivolt, or ohm sensor types.
- ±0.18°F accuracy for Pt100 RTD inputs.
- Transmitter-Sensor Matching improving accuracy by 75% by eliminating interchangeability error.
- Hot Backup feature reducing risk of measurement loss by 80% via automatic sensor switchover.
- Sensor Drift Alert for continuous monitoring of dual-sensor differential temperature.
- HART version approved for use in Safety Instrumented Systems (IEC 61508 tested).
- Dual-compartment housing isolating electronics and terminal wiring compartments.
- Compliant with NAMUR NE 21, NE 43, and NE 89 recommendations for EMC and diagnostics.
Industrial Applications
The Rosemount 3144P is well suited to oil and gas processing, petrochemical facilities, pharmaceutical manufacturing, food and beverage production, and utility plants across Oman requiring precise, reliable temperature measurement in critical control and safety loops. Its dual-sensor and Hot Backup capabilities make it especially valuable in processes where continuous temperature visibility cannot be interrupted, such as reactor jacket monitoring or fired-heater tube-skin temperature loops.
Working closely with plant engineers in the region, Seven Star LLC supports refineries, petrochemical plants, and utilities throughout the Sohar and Salalah economic zones and the broader GCC region with the Rosemount 3144P’s industry-leading temperature measurement reliability.
Technical Specifications
Full technical parameters for the Rosemount 3144P temperature transmitter:
| Parameter | Specification |
|---|---|
| Model | Rosemount 3144P |
| Accuracy | ±0.18°F for Pt100 RTD |
| Sensor Inputs | RTD (2/3/4-Wire), Thermocouple, Millivolt, Ohm |
| Input Configuration | Single-Sensor or Dual-Sensor |
| Communication Protocols | 4-20mA HART or FOUNDATION Fieldbus |
| Power Supply | 9.0 to 32VDC, 11mA Maximum |
| Key Diagnostic Features | Transmitter-Sensor Matching, Hot Backup, Sensor Drift Alert |
| Safety Certification | SIL-Rated per IEC 61508 (HART Version) |
| Housing | Dual-Compartment (Electronics/Terminal Isolation) |
| EMC Compliance | NAMUR NE 21, NE 43, NE 89 |
Why Choose Seven Star LLC for the Rosemount 3144P Temperature Transmitter
Temperature loops feeding a Safety Instrumented System carry documentation requirements that go beyond the transmitter itself – IEC 61508 certificates, Transmitter-Sensor Matching records, and Hot Backup configuration all need to be verifiable during a SIL audit. Seven Star LLC’s engineers help customers assemble that documentation package alongside the 3144P order, and confirm sensor type (RTD, thermocouple, millivolt) and wiring configuration (2/3/4-wire) against the existing junction box before shipment, avoiding a field rewiring exercise. Because dual-sensor and Hot Backup configurations are often specified for critical loops that cannot tolerate a measurement gap, we also plan spare-sensor and spare-transmitter stock so a failed primary sensor can be swapped without waiting on a fresh import, and we support customers across Oman’s refining, petrochemical, and utility sectors with regional delivery timed to planned maintenance windows.
Request a Quote for Rosemount 3144P Temperature Transmitter
To submit a formal Request for Quote (RFQ), check current availability and lead time, or arrange technical consultation for the Rosemount 3144P Temperature Transmitter, please contact Seven Star LLC today. With fast quotation turnaround and technical support, our engineers are ready to assist with rapid sourcing for your temperature measurement and safety instrumented system projects.
Related Products
- Honeywell 8500C Plus Balancer (Chadwick-Helmuth)
- IDS cards,RC8DA . 160050037
- JUMO dTRANS T100 Screw-In RTD Temperature Probe
- Isotech Semi-Standard PRTs – High-Stability Reference Platinum Thermometers
- Endress+Hauser TR66-CCEEC2XCKDA0 iTHERM Temperature Sensor U=350mm
- ABB TTF300.S3.C.2.H.BF-C4.C Field-Mount Temperature Transmitter
Also available: Rosemount 214C RTD Temperature Sensor · Rosemount 848T High Density Temperature Transmitter
Datasheets & Documents
- Datasheet Rosemount 3144P Temperature Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
Related products
Frequently Asked Questions
The 3144P can be configured for RTD (2, 3, or 4-wire), thermocouple, millivolt, or ohm sensor inputs, in single-sensor or dual-sensor configurations.
Hot Backup automatically switches the temperature measurement to a backup sensor if the primary sensor fails, reducing the risk of losing important measurements by 80%.
Yes. The HART version of the 3144P is approved for use in Safety Instrumented Systems, with third-party validated metrics tested per IEC 61508.
Transmitter-Sensor Matching trims the transmitter to the specific sensor's calibration constants, eliminating interchangeability error and improving accuracy by 75%.
Yes. Seven Star LLC is an experienced supplier of Emerson Rosemount instrumentation in Oman and the GCC, providing genuine products with full support.

Reviews
There are no reviews yet.