The Rosemount 644 Head Mount Temperature Transmitter is one of the most widely deployed temperature transmitters in the global process industry, trusted for its measurement accuracy, transmitter-sensor matching, and long-term reliability in demanding plant environments. Built to mount directly inside a DIN Form B connection head on a thermowell assembly, the Rosemount 644 accepts RTD, thermocouple, millivolt, and ohms inputs and converts the sensor signal into a stable digital or analog output using HART®, FOUNDATION™ Fieldbus, or PROFIBUS® PA protocols – giving engineers a single transmitter platform that covers nearly every temperature measurement point in a facility.

In Oman and the GCC, Seven Star LLC supplies the Rosemount 644 Head Mount Temperature Transmitter on request with manufacturer documentation and technical backing. Facilities across Muscat, Sohar, and Salalah can source Emerson Rosemount instrumentation through Seven Star LLC, with availability and lead time confirmed at quotation.

Measurement Principle

The Rosemount 644 operates by accepting a resistance or voltage signal from a connected RTD or thermocouple sensor and applying Callendar-Van Dusen constants unique to the matched sensor to correct for individual sensor curve variation, reducing total measurement error to a fraction of what a generic transmitter-sensor pairing would achieve. The transmitter’s onboard diagnostics continuously evaluate sensor health, flagging drift, degradation, or open/short-circuit sensor failure well before the condition affects process control – a critical capability in continuous processes where an undetected temperature excursion can mean a batch loss or a safety event.

Dual-sensor variants of the Rosemount 644 support Hot Backup™ functionality, automatically switching to a secondary sensor if the primary sensor fails, and providing a sensor drift alert that compares both sensor readings in real time. Because the transmitter performs signal conditioning and linearization directly at the measurement point rather than at a remote marshalling cabinet, the resulting 4-20 mA or digital signal is immune to the lead-wire resistance errors, electrical noise pickup, and cable-run signal degradation that plague remote RTD wiring – delivering a clean, drift-free reading regardless of how far the control room sits from the field.

Engineering Design of the Rosemount 644

The Rosemount 644 is a compact, circular electronics module engineered to fit inside a standard DIN Form B connection head, the industry-standard housing style used on the vast majority of thermowell and sensor assemblies worldwide. This form-factor compatibility means the Rosemount 644 can retrofit directly into existing temperature assemblies without requiring a new housing, thermowell, or wiring scheme – a significant advantage during plant upgrades and transmitter replacement programs. The module terminal block accepts 2, 3, or 4-wire RTD connections as well as thermocouple leads, with a dedicated test terminal that allows technicians to simulate or verify the output signal without disconnecting field wiring.

An optional Local Operator Interface (LOI) provides on-site configuration and diagnostic access using magnetic push-buttons operated through the housing glass, allowing range, damping, and alarm settings to be adjusted in the field without opening the enclosure in a hazardous area. The electronics are conformal-coated and rated for continuous operation across an extreme ambient temperature range, and the transmitter is certified for installation in explosion-proof, flameproof, intrinsically safe, and non-incendive hazardous locations, making it suitable for refineries, offshore platforms, gas processing trains, and other Zone 0/1/2 classified areas common throughout Oman’s oil and gas sector.

Key Features

The Rosemount 644 Head Mount Temperature Transmitter combines proven measurement accuracy with a feature set built specifically for demanding industrial temperature applications.

  • Transmitter-sensor matching using Callendar-Van Dusen constants reduces total measurement error compared with unmatched sensor-transmitter pairings.
  • Hot Backup™ dual-sensor capability automatically transfers to a secondary sensor on primary sensor failure, maintaining continuous measurement without a process interruption.
  • Thermocouple degradation diagnostics continuously monitor thermocouple health and warn of impending sensor failure before it affects the loop.
  • Minimum and maximum temperature tracking records process excursions for troubleshooting and historical trend analysis.
  • Compatible with HART, FOUNDATION Fieldbus, and PROFIBUS PA protocols for seamless integration into existing DCS and asset management systems.
  • Fits the standard DIN Form B connection head, enabling drop-in retrofit into existing thermowell assemblies without mechanical modification.
  • Optional Local Operator Interface allows field configuration and verification without opening the housing in classified hazardous areas.
  • Certified for explosion-proof, flameproof, and intrinsically safe installation across global hazardous-area standards.

Industrial Applications

The Rosemount 644 is deployed across virtually every process industry that requires reliable point temperature measurement, including oil and gas production and refining, petrochemical processing, power generation, food and beverage manufacturing, and life sciences production. Its head-mount, DIN Form B form factor makes it the default choice for retrofitting legacy thermowell installations throughout process trains, tank farms, compressor stations, and utility systems where thousands of individual temperature points must be measured with consistent accuracy and minimal maintenance overhead.

In Oman and the GCC, Seven Star LLC supplies the Rosemount 644 to engineering, procurement, and construction contractors, oilfield service companies, and plant maintenance teams across the Sultanate of Oman and the wider GCC. From the Sohar and Salalah free zones to upstream facilities in the interior and offshore platforms in the Arabian Sea, Seven Star LLC supplies Emerson Rosemount temperature transmitters on request with manufacturer documentation and responsive regional technical support.

Technical Specifications

The table below summarizes the core specifications of the Rosemount 644 Head Mount Temperature Transmitter.

Parameter Specification
Model Rosemount 644
Housing Style DIN Form B head mount (also available for DIN Form A / rail mount)
Input Types RTD, thermocouple, millivolt, ohms
Output Protocols HART, FOUNDATION Fieldbus, PROFIBUS PA
Sensor Matching Callendar-Van Dusen constants for reduced total error
Redundancy Hot Backup™ dual-sensor failover with drift alert
Diagnostics Thermocouple degradation monitoring, min/max temperature tracking
Local Interface Optional Local Operator Interface (LOI) with magnetic push-buttons
Hazardous Area Certification Explosion-proof, flameproof, intrinsically safe, non-incendive
Typical Applications Oil & gas, petrochemical, power generation, food & beverage, life sciences

Request a Quote for Rosemount 644

Facilities throughout Oman and the GCC can request a formal quotation for the Rosemount 644 Head Mount Temperature Transmitter directly from Seven Star LLC, with lead time confirmed at quotation, technical datasheet downloads, and full support from our instrumentation division. In Oman and the GCC, Seven Star LLC supplies each unit on request with manufacturer documentation and the local technical support needed to specify critical temperature measurement loops correctly. Contact our sales engineering team today to specify the correct sensor input, housing, and protocol configuration for your application.

Browse the full Rosemount range or see more Temperature Instrumentation products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 644 Head Mount Temperature Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does the Rosemount 644 temperature transmitter measure and what inputs does it accept?
The Rosemount 644 accepts RTD, thermocouple, millivolt, and ohms inputs from a connected temperature sensor and converts the signal into a stable 4-20 mA HART, FOUNDATION Fieldbus, or PROFIBUS PA output, making it suitable for virtually any point temperature measurement application in a process plant.
02Does the Rosemount 644 fit standard thermowell assemblies?
Yes. The Rosemount 644 is designed to mount directly inside a standard DIN Form B connection head, so it can retrofit into existing thermowell and sensor assemblies without requiring new housings or mechanical rework, which significantly reduces installation cost and plant downtime during upgrades.
03What sizes, mounting styles, and protocol options are available for the Rosemount 644?
The Rosemount 644 is available in head-mount (DIN Form B) and rail-mount (DIN Form A) configurations, with single or dual-sensor input, and supports HART, FOUNDATION Fieldbus, and PROFIBUS PA communication protocols to match the host control system.
04Can the Rosemount 644 integrate with legacy 4-20 mA control systems?
Yes. In standard HART configuration the Rosemount 644 communicates over a conventional 4-20 mA analog loop with superimposed HART digital signal, allowing it to integrate directly into legacy analog control systems while still providing full digital diagnostic and configuration access.
05Is Seven Star LLC a trusted supplier for Rosemount products?
Yes. Seven Star LLC is the trusted supplier and regional supplier for Rosemount instrumentation in Oman and the GCC, supplying Emerson Rosemount products on request with local technical backing.