Rosemount 396P-02-10-55 TUpH pH/ORP Sensor
Description
Overview
The Rosemount 396P-02-10-55 is a TUpH-series insertion and submersion pH/ORP sensor from Emerson’s Rosemount Analytical liquid analysis range, engineered for continuous pH measurement in harsh, dirty and abrasive process streams. Housed in a molded, reinforced polypropylene body with 1 in. MNPT front and rear facing threads, the sensor is suitable for in-line insertion, tank submersion or flow-through installation. This particular build code (02-10-55) is supplied without an integral preamplifier and a 15 ft cable, fitted with the GPLR hemi-bulb general-purpose glass electrode covering the full 0–14 pH range, and configured for Pt100 RTD automatic temperature compensation compatible with the Rosemount 54, 54e, 1055, 81, 3081, 4081, 5081 and Xmt analyzer/transmitter families.
Backed by manufacturer datasheet documentation, Seven Star LLC proudly supplies the Rosemount 396P-02-10-55 pH/ORP sensor to water treatment plants, desalination facilities and process industries throughout Oman and the wider GCC. Seven Star LLC supplies the Rosemount 396P-02-10-55 on request with manufacturer documentation and local technical support – useful for operators in the Sultanate of Oman running continuous pH control loops.
Measurement Principle
The Rosemount 396P generates a pH signal through a glass-membrane electrode pair combined with a patented TUpH reference junction – the entire plastic tip surrounding the glass pH bulb – built from micron-sized reference pathways engineered for ionic exchange. This large-area junction resists plugging by suspended solids far better than a conventional small ceramic frit, which is the dominant cause of pH signal drift in slurry, wastewater and pigment/dye applications. A long internal helical reference pathway further slows the migration of poisoning ions such as sulfide, mercury, cyanide and ammonia toward the reference element, extending stable operating life between maintenance cycles considerably beyond that of standard pH sensors.
Because the raw millivolt signal from a glass pH electrode is extremely high impedance and highly susceptible to noise, the 396P-02-10-55 pairs with a remote preamplifier (per the “02” build code) that converts the signal into a low-impedance, noise-resistant output capable of transmission over long cable runs to the analyzer. A titanium solution ground, built around the electrode in an annular configuration, provides continuous sensor diagnostics when used with compatible Rosemount analyzers, flagging reference degradation or glass impedance issues before they cause a control loop upset. The AccuGlass pH glass formulation used in the sensing bulb further resists cracking and reduces sodium ion error at high pH, giving accurate, drift-resistant readings across the entire 0–14 pH measuring range.
Engineering Design of the Rosemount 396P-02-10-55
The 396P-02-10-55 wetted assembly is built from titanium, polypropylene, EPDM and glass, chosen for broad chemical compatibility with acidic, alkaline and particulate-laden process streams. The sensor threads directly into a 1 in. MNPT process connection and can be installed via insertion fitting, ball valve retractable assembly, submersion mounting or a flow-through tee, giving plant engineers flexibility to match the installation to available process access. This build ships without an integral preamplifier, meaning it is designed to pair with a remote junction box preamplifier for sensor-to-analyzer distances beyond 15 ft, keeping the sensor head compact for tight installation points.
The recessed, shrouded standard tip on hemi-bulb variants like the 396P-02-10-55 protects the glass electrode from mechanical damage during installation and cleaning, while an optional slotted tip is available where higher process flow across the glass surface is desired. Automatic temperature compensation is built in via a Pt100 RTD (per the “55” compatibility code), matched to the Rosemount 54, 54e, 1055, 81, 3081, 4081, 5081 and Xmt analyzer and transmitter platforms. The sensor is rated for operation up to 100°C (212°F) and 150 psig depending on glass style, and weighs approximately 0.45 kg, making it straightforward to service or replace without special lifting equipment.
Key Features
The Rosemount 396P pH/ORP sensor delivers a combination of maintenance reduction and measurement stability valued across GCC process and utility applications:
- The Rosemount 396P patented TUpH large-area reference junction resists plugging by suspended solids, cutting routine maintenance in dirty and slurry-laden process streams.
- Helical reference pathway slows contamination by poisoning ions, extending stable sensor life well beyond conventional ceramic-frit designs.
- AccuGlass GPLR hemi-bulb electrode covers the full 0–14 pH range with reduced cracking risk and lower sodium ion error at high pH.
- Rugged polypropylene, titanium, EPDM and glass wetted construction resists chemical attack in acidic, alkaline and particulate-heavy media.
- Built-in Pt100 automatic temperature compensation ensures accurate pH readings across varying process temperatures.
- Titanium solution ground provides advanced sensor diagnostics for preventative maintenance on compatible Rosemount analyzers.
- Versatile 1 in. MNPT process connection supports insertion, submersion and flow-through installation configurations.
- Compact, lightweight sensor body simplifies field replacement without disrupting adjacent process piping.
Industrial Applications
The Rosemount 396P-02-10-55 is specified wherever continuous pH monitoring must survive harsh, dirty or abrasive service conditions. Typical duty includes lime slurry neutralization in wastewater treatment, pulp and paper machine headbox pH control, pigment and dye process monitoring, desalination and reverse osmosis pretreatment pH trimming, and general effluent and utility water treatment across refineries, petrochemical complexes and power plants. Its resistance to fouling makes it especially well suited to streams carrying high concentrations of suspended solids, where conventional pH probes require frequent cleaning and recalibration.
Working closely with plant engineers in the region, Seven Star LLC distributes the 396P-02-10-55 pH/ORP sensor to municipal water authorities, industrial water treatment contractors and process plants across Oman, Muscat, and the broader GCC, including facilities supported through the Sohar and Salalah industrial and free-trade zones. Technical support with selection of the Rosemount 396P helps desalination plants, wastewater treatment works and process utilities in the Sultanate of Oman specify Rosemount pH instrumentation with confidence.
Technical Specifications
Key technical parameters for the Rosemount 396P pH/ORP sensor, model Rosemount 396P-02-10-55, are summarized below for engineering reference.
| Parameter | Specification |
|---|---|
| Model | Rosemount 396P-02-10-55 |
| Measurement Range | pH 0–14; ORP -1500 to +1500 mV |
| Electrode Type | GPLR hemi bulb, General Purpose Low Resistivity (Code 10) |
| Preamplifier / Cable | Without integral preamplifier, 15 ft cable (Code 02) |
| Analyzer / TC Compatibility | Models 54, 54e, 1055, 81, 3081, 4081, 5081, Xmt – Pt100 RTD (Code 55) |
| Wetted Materials | Titanium, polypropylene, EPDM, glass |
| Process Connection | 1 in. MNPT, front and rear facing threads |
| Temperature Range | 0–100°C (32–212°F) |
| Pressure Rating (Hemi Bulb) | 100–1136 kPa abs (0–150 psig) |
| Minimum Conductivity | 75 µS/cm nominal, 100 µS/cm recommended |
| Installation | Insertion, submersion, or flow-through |
| Weight | 0.45 kg (1 lb) |
| Reference Technology | TUpH large-area reference junction with helical pathway |
Request a Quote for Rosemount 396P-02-10-55 TUpH pH/ORP Sensor
Seven Star LLC invites water treatment engineers, procurement teams and plant operators across Oman and the GCC to request a formal RFQ for the Rosemount 396P-02-10-55 pH/ORP sensor. With fast quotation turnaround and technical support, Seven Star LLC supplies frequently specified TUpH sensor configurations on request, provides the full technical datasheet for engineering review, and offers direct access to our instrumentation division for application sizing and analyzer compatibility support.
Related Products
Datasheets & Documents
- Datasheet Rosemount 396P-02-10-55 TUpH pH/ORP Sensor Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments
Milestones
1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.
Rosemount products we list
FamilyModelsTypical use
Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 396P-02-10-55 TUpH pH/ORP Sensor
Answers from our engineering team on installation, compatibility and integration.
01What makes the Rosemount 396P suited to dirty or abrasive process streams?
The Rosemount 396P uses a patented TUpH large-area reference junction with a helical reference pathway that resists plugging by suspended solids and slows contamination by poisoning ions, giving it far longer stable operating life than conventional ceramic-frit pH sensors in slurry and wastewater duty.
02How much cable comes with the 396P-02-10-55 and does it need a preamplifier?
This build code ships without an integral preamplifier and with a 15 ft cable, so it is designed to be paired with a remote junction box preamplifier for sensor-to-analyzer distances beyond 15 ft, which keeps the sensor head compact for tight installation points.
03What process connections and materials does the Rosemount 396P-02-10-55 use?
The sensor uses a 1 in. MNPT front and rear facing thread with wetted materials of titanium, polypropylene, EPDM and glass, and is compatible with insertion, submersion and flow-through mounting configurations.
04Which Rosemount analyzers and transmitters is this sensor compatible with?
The 396P-02-10-55 build code is configured with Pt100 RTD temperature compensation for compatibility with the Rosemount 54, 54e, 1055, 81, 3081, 4081, 5081 and Xmt analyzer and transmitter families.
05Is Seven Star LLC an experienced supply partner for Rosemount products?
Yes. Seven Star LLC supplies Rosemount products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.