- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Rosemount
Rosemount 1408H Hygienic Radar Level Transmitter IO-Link
Description
Rosemount 1408H 80 GHz hygienic radar level transmitter with IO-Link
The Rosemount 1408H is a compact non-contacting radar level transmitter built for hygienic tanks. It measures continuous level with 80 GHz FMCW radar from a polished 316L stainless steel housing, and it is aimed at food, beverage and similar sanitary processes where a tank is cleaned with CIP and SIP cycles and washed down on the outside. Seven Star LLC supplies the 1408H in Oman and the GCC as an independent supplier in Muscat.
The data sheet describes the signal output as IO-Link, and the device provides two configurable outputs: output 1 works as a digital output or IO-Link line, and output 2 works as a digital output or an active 4-20 mA analog output. The process connection is an ISO 228/1-G1 thread, and a range of hygienic adapters screws onto it.
Reading the 1408H model code
The data sheet shows a typical model string of 1408H I CA C10 Q4 Q8. Taken part by part:
- 1408H: the transmitter itself, with a G1 thread.
- I: the signal output code, IO-Link.
- CA: the hygienic process connection adapter, here a 1½-in. Tri Clamp.
- C10: a cable option, here a hygienic M12 patch cable of 32.8 ft (10 m).
- Q4 and Q8: a calibration data certificate and EN 10204 3.1 material traceability.
Options such as the cable and the certificates are not printed in the model string on the nameplate, so state them again when you reorder.
Technical specifications of the 1408H
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Rosemount (Emerson) / 1408H |
| Measurement principle | FMCW radar, 77 to 81 GHz (76 to 77 GHz in applicable countries) |
| Maximum measuring range | 33 ft (10 m); up to 49 ft (15 m) with good surface reflection such as water-based media |
| Accuracy (reference conditions) | ±0.08 in. (±2 mm) |
| Repeatability | ±0.04 in. (±1 mm) |
| Beam angle | 10° |
| Minimum dielectric constant | 2 |
| Update rate | Minimum 1 per second, typically 5 per second |
| Process temperature | -4 to 302 °F (-20 to 150 °C) with adapter; -40 to 302 °F without adapter |
| Process pressure | -15 to 116 psig (-1 to 8 bar); flanges for non-pressurized applications only |
| Ambient temperature | -40 to 176 °F (-40 to 80 °C), reduced at high process temperature |
| Power supply | 18 to 30 Vdc at the transmitter |
| Outputs | Digital output / IO-Link; digital or active 4-20 mA |
| Ingress protection | IP66/68/69 and IP6K9K, NEMA 4X, with a suitable M12 connector fitted |
| Housing material | Polished 316L stainless steel (EN 1.4404) |
| Weight | 1.1 lb (0.5 kg) without adapter |
How the 1408H measures level
The transmitter sends a frequency-swept microwave signal toward the product and compares the returning echo with the signal being sent. The frequency difference gives the distance to the surface, and the level follows from the tank height. Because nothing touches the product, density, viscosity, temperature, pressure and pH do not change the reading, and there are no wetted moving parts to clean or wear.
The 80 GHz frequency gives a narrow 10° beam. At 6.6 ft (2 m) the beam is about 1.2 ft (0.4 m) wide and at 32.8 ft (10 m) about 5.7 ft (1.7 m), which is why the unit copes with small tanks and nearby internals better than lower-frequency radar. Level can also be reported as distance, electronics temperature and signal strength over IO-Link.
Where the 1408H fits in the system
IO-Link works through a master that collects process data, events and parameters from each device and passes them to the PLC over fieldbus or industrial Ethernet. The 1408H uses IO-Link revision 1.1 at 38.4 kBaud (COM2) with SIO mode, and it expects a Class A master port. Configuration can be done with an IODD-compliant tool or a DTM system with an IODD interpreter. For analog loops, output 2 gives the active 4-20 mA signal.
Other Rosemount radar devices from the same supplier family, such as the 1208 and 3408, address different duties: the 1208 is a compact PVDF unit for water and open channels, and the 3408 is a wireless radar unit. The 1408H is the stainless hygienic version in that group.
Selection checklist for the 1408H
- Confirm that the tank is in the 33 ft (10 m) range, or 49 ft (15 m) for water-based media with a clean surface echo.
- Pick the hygienic adapter: 1½-in. or 2-in. Tri Clamp, DN32, DN40 or DN50 dairy coupling (DIN 11851), VARIVENT type F or N, or the D50 weld-in adapter.
- Check that the adapter approvals you need are present; 3-A, EHEDG, FDA and CRN are listed per adapter in the data sheet.
- Decide on 4-20 mA, digital switching or pure IO-Link, and confirm the PLC side has an IO-Link master.
- Choose cable or connector accessories, and keep the IO-Link run to a maximum of 65.6 ft (20 m) between device and master.
- Check nozzle height against the table: for example 3.9 in. (100 mm) at a 1-in. nozzle, and shorter limits apply for 3-A and EHEDG installations.
Installing and maintaining the 1408H
Mount the 1408H with a clear view of the product surface, away from the inlet stream, not on a manway cover and not above a side manway. Keep it within a 3° tilt of vertical, at least 8 in. (200 mm) from the tank wall and ideally half a tank radius away. The nozzle inside should be smooth with no weld spatter or deposits.
The 24 V supply goes to brown (L+) and blue (L-) wires of the M12 connector, with white as output 2 and black as output 1 / IO-Link. The ingress rating applies only when a suitably rated M12 connector is plugged in. Beyond that, there is little to service on a non-contacting unit; check the adapter O-ring (EPDM or FKM options exist) at each hygiene audit and keep a spare cable and O-ring set.
Typical uses of the 1408H in Oman and the GCC
Dairies, juice and beverage plants, bottling lines, bakeries and pharmaceutical or cosmetic batch rooms in the region run with hot washdowns and high ambient temperatures. A sealed stainless radar unit with a drip-off housing suits those conditions better than a mechanical float. Typical points are storage tanks, mixing tanks with agitators, batch fill vessels and CIP cleaning-agent tanks, where the transmitter can watch levels through and after the cleaning cycle.
Water-treatment skids and chemical dosing tanks in utilities and industry can also use a stainless radar, provided the process wetted materials and temperature suit the data sheet limits.
1408H accessories and spare parts
| Item | Part number(s) from the data sheet |
|---|---|
| 1½-in. Tri Clamp adapter | FB-1001 (FB-1001Q8 with material certificate) |
| 2-in. Tri Clamp adapter | FB-1002 (FB-1002Q8) |
| DN32 / DN40 / DN50 dairy coupling | FB-1020 / FB-1021 / FB-1022 |
| VARIVENT F / N | FB-1010 / FB-1011 |
| D50 weld-in adapter | FB-1041; G1 welding mandrel FB-6041 |
| Hygienic O-rings | FB-3001 (FKM, 1 pc), FB-3002 (FKM, 5 pcs), FB-3003 (EPDM, 5 pcs) |
| Mounting bracket with extension and lock nut | 01408-5000-0001 |
| Wireable M12 terminal connector | FB-4000 |
| IO-Link master hubs | FB-5104, FB-5108 (PROFINET); FB-5204, FB-5208 (EtherNet/IP) |
| IO-Link USB communicator / software | FB-5301 / FB-5401 |
Information to send with your 1408H RFQ
- Complete model code including the adapter and cable codes
- Tank height, diameter, nozzle size and nozzle height
- Product, temperature range and CIP/SIP cleaning temperature
- Required output: IO-Link, switch or 4-20 mA
- Hygienic approvals required (3-A, EHEDG, FDA) and certificate options Q4 or Q8
- Quantity and delivery location in Oman or the GCC
Documents and quotation
The manufacturer product data sheet for the 1408H is attached on this page, and it is the document to check for the full ordering table, dimensional drawings and approvals before you place an order. Please note that the sheet covers the IO-Link version of the transmitter.
Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. Send us the 1408H model code or your process data and we will reply with availability, lead time and a quotation.
Datasheets & Documents
- Datasheet Rosemount 1408H Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
| Established | 1956, Minnesota, USA, as Rosemount Engineering Company |
|---|---|
| Founders | Frank D. Werner, Robert E. Keppel and Vernon H. Heath |
| Ownership | Acquired by Emerson in 1976; now an Emerson brand |
| Product families | Pressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments |
Milestones
- 1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
- 1969: The Rosemount 1151 analog pressure transmitter is introduced.
- 1976: Emerson acquires Rosemount.
- 1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
- 2001: The 3051S generation follows.
Rosemount products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure transmitters | 3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm seals | Pressure, differential pressure and remote seal measurement |
| DP flow and DP level | 3051CF flowmeter, 3051L, 3051SAL | Flow through primary elements, and level in pressurised vessels |
| Temperature | 644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-input | Process temperature, high-density multipoint and tank temperature |
| Radar and level | 5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gauges | Level in tanks, separators and custody transfer tank gauging |
| Level switches | 2120, 2140, 2160 wireless, 702 discrete transmitter | High and low level alarms, overfill protection and pump protection |
| Flowmeters | 8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquid | Water, steam and gas flow, and fiscal gas and liquid metering |
| Liquid analysis | 396P TUpH, 396PVP, 499ACL chlorine sensor | pH, ORP and free chlorine in water and process streams |
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 1408H Hygienic Radar Level Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What measuring range does the Rosemount 1408H have?
The data sheet gives a maximum range of 33 ft (10 m). Up to 49 ft (15 m) is possible when the product surface reflects well, for example water-based media with a dielectric constant above 10.
02Which outputs does the 1408H provide?
It has two configurable outputs. Output 1 is a digital output or the IO-Link line, and output 2 is a digital output or an active 4-20 mA analog output. The unit runs on 18 to 30 Vdc.
03How is the 1408H connected to the process?
It has an ISO 228/1-G1 thread that takes hygienic adapters: Tri Clamp, DIN 11851 dairy coupling, VARIVENT or a D50 weld-in adapter. A mounting bracket is also listed.
04What process temperature and pressure can it take?
With an adapter the process temperature is -4 to 302 °F (-20 to 150 °C), and pressure is -15 to 116 psig (-1 to 8 bar). Flanges are for non-pressurized applications only.
05What is the beam angle and why does it matter?
The beam angle is 10°. A narrow beam reduces echoes from tank walls and internals, which helps in small vessels, but the unit still needs a clear view of the surface and a smooth nozzle.