Brand:

Rosemount 848T High Density Temperature Transmitter

Description

Overview

Rosemount 848T is a high-density, multi-input temperature transmitter from Emerson that consolidates as many as eight independent temperature measurement points into a single field device, dramatically reducing the number of transmitters, junction boxes, and cable runs required for large equipment such as tanks, reactors, heat exchangers, and rotating machinery. Available in FOUNDATION Fieldbus and WirelessHART versions, the Rosemount 848T accepts RTD, thermocouple, ohm, millivolt, and 4–20 mA inputs, giving instrumentation engineers a single flexible platform for mixed sensor types on the same asset.

In Oman and the GCC, Seven Star LLC proudly supplies the Rosemount 848T High Density Temperature Transmitter to refineries, LNG facilities, power plants, and process manufacturers across the Sultanate of Oman and the wider GCC.

Measurement Principle

The Rosemount 848T operates as a multiplexed input module, sequentially scanning up to eight sensor channels and converting each raw RTD, thermocouple, ohm, or millivolt signal into a linearized, temperature-compensated digital reading. Each input channel is independently configurable for sensor type, range, and alarm behavior, so a single transmitter can simultaneously service a mix of thermocouples on a furnace and RTDs on adjacent piping without requiring separate devices for each sensor technology.

Because the readings are transmitted digitally over FOUNDATION Fieldbus or WirelessHART rather than as individual 4–20 mA loops, the Rosemount 848T eliminates the marshalling cabinets, multi-core cabling, and I/O card real estate that traditional point-to-point wiring would demand for the same number of measurement points. Built-in diagnostics flag open-circuit, short-circuit, and out-of-range sensor conditions on a per-channel basis, so a single failed thermocouple does not compromise visibility of the other seven measurement points on the same device.

Engineering Design of the Rosemount 848T

The Rosemount 848T is built in a field-hardened enclosure suitable for outdoor and hazardous-area installation, with a rail-mount or head-mount form factor depending on the model configuration selected. The wireless variant integrates Emerson’s SmartPower module, which is engineered to deliver up to ten years of maintenance-free operation from a single power module, removing the need for external wiring or battery replacement visits on hard-to-access equipment such as tank farms and remote rotating assets.

Terminal blocks are clearly labeled per input channel to simplify field wiring and troubleshooting, and the transmitter supports standard configuration tools including AMS Device Manager and, for the wireless model, Emerson’s Smart Wireless Gateway for integration into an existing WirelessHART mesh network. The compact multi-input architecture means a single junction box location can now serve an entire vessel or skid, simplifying both the original installation and any future sensor additions.

Key Features

The Rosemount 848T reduces wiring complexity and device count wherever multiple temperature points need to be monitored from one location.

  • Up to eight independent input channels accept RTD, thermocouple, ohm, millivolt, and 4–20 mA sensor signals on a single transmitter.
  • Available in FOUNDATION Fieldbus and WirelessHART versions to match wired digital bus or wireless mesh network architectures.
  • Per-channel diagnostics detect open-circuit, short-circuit, and sensor drift conditions without affecting the other measurement channels.
  • SmartPower module on the wireless variant supports up to ten years of maintenance-free, battery-based operation.
  • Consolidating multiple sensors into one device significantly reduces junction boxes, marshalling cabinets, and cable tray requirements.
  • Compatible with AMS Device Manager and Smart Wireless Gateway for centralized configuration and network management.
  • Field-hardened enclosure supports installation in hazardous-area classified zones common to oil, gas, and petrochemical plants.
  • Mixed sensor-type support allows thermocouples and RTDs to be monitored from the same transmitter on a single asset.

Industrial Applications

The Rosemount 848T is widely applied on large storage tanks, distillation columns, heat exchangers, and rotating equipment bearings where multiple temperature points must be monitored across a single piece of equipment. In Oman’s LNG, refining, and power generation sectors, the transmitter is used to consolidate tank-farm skin thermocouples, reactor multi-point profiles, and turbine bearing RTDs into a fraction of the field devices a traditional single-input architecture would require, cutting both capital cost and long-term maintenance burden.

In Oman and the GCC, Seven Star LLC distributes the Rosemount 848T to EPC contractors and plant operators throughout the Sultanate of Oman and the broader GCC, including projects in the Sohar and Salalah industrial and free zones. Our technical staff in Muscat help engineering teams select the right channel count, sensor mix, and Fieldbus or Wireless configuration for each application.

Technical Specifications

The table below summarizes the core specifications of the Rosemount 848T high density temperature transmitter as published in Emerson’s official product documentation.

Parameter Specification
Model Rosemount 848T
Input Channels Up to 8 (FOUNDATION Fieldbus); up to 4 configurable inputs (WirelessHART)
Supported Sensor Types RTD, thermocouple, ohm, millivolt, and 4–20 mA inputs
Communication Protocol FOUNDATION Fieldbus or WirelessHART
Power Options Fieldbus bus-powered; SmartPower module for wireless variant
Diagnostics Per-channel open-circuit, short-circuit, and out-of-range detection
Configuration Tools AMS Device Manager; Smart Wireless Gateway (wireless variant)
Enclosure Field-hardened housing rated for outdoor and hazardous-area installation
Mounting Rail-mount or head-mount depending on configuration

Request a Quote for Rosemount 848T

Seven Star LLC invites instrumentation engineers, EPC contractors, and plant maintenance teams across Oman and the GCC to submit a formal request for quotation for the Rosemount 848T High Density Temperature Transmitter. In Oman and the GCC, we supply on request, provide the Emerson technical datasheet on request, and connect customers directly with our instrumentation division for channel-count sizing, Fieldbus or Wireless network planning, and hazardous-area certification guidance.

Browse the full Rosemount range or see more Temperature Instrumentation products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 848T High Density Temperature Transmitter

Answers from our engineering team on installation, compatibility and integration.

01How many sensors can the Rosemount 848T monitor at once?
The Rosemount 848T FOUNDATION Fieldbus version supports up to eight independent temperature input channels, while the WirelessHART version supports up to four configurable inputs, all from a single transmitter.
02What sensor types does the Rosemount 848T accept?
The transmitter accepts RTD, thermocouple, ohm, and millivolt inputs, plus 4–20 mA signals on the wireless variant, and different channels can be configured for different sensor types simultaneously.
03How long does the wireless version run without external power?
The WirelessHART Rosemount 848T uses Emerson’s SmartPower module, engineered to support up to ten years of maintenance-free operation, which removes the need for field wiring or frequent battery replacement.
04Can the Rosemount 848T integrate with an existing wireless network?
Yes, the wireless version joins an existing WirelessHART mesh network and is managed through Emerson’s Smart Wireless Gateway, while the Fieldbus version integrates directly with a FOUNDATION Fieldbus segment and AMS Device Manager.
05Is Seven Star LLC a trusted supplier for Rosemount products?
Yes, Seven Star LLC supplies Rosemount products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.