Brand:

JUMO tecLine CR-4P Hygienic Four-Electrode Conductivity Sensor, Type 202930

Description

One conductivity sensor for the span from ultrapure rinse water to caustic CIP

The JUMO tecLine CR-4P (type 202930) is a conductive four-electrode conductivity sensor that fills the gap between two-electrode cells and inductive measurement. Because excitation and voltage measurement are separated across two pairs of electrodes, polarisation effects recede and the influence of contamination or deposits is reduced. The datasheet gives a typical range of about 1 uS/cm to 600 mS/cm from a single sensor, so the same cell can follow rinse water, product and cleaning solution in food, beverage, pharmaceutical and biotechnology plants. It mounts through the hygienic JUMO PEKA adapter system and is designed to EHEDG and FDA standards.

Technical specifications

Parameter Specification
Measuring principle Conductive, four stainless-steel electrodes (two current, two voltage) in a circular plastic body
Typical measuring range 1 uS/cm to approx. 600 mS/cm; range also depends on the transmitter
Accuracy Plus or minus 5 % of measured value
Cell constant Typically K = 0.3 to 0.4 per cm; exact value on the nameplate and quality certificate
Operating temperature -10 to +120 degC, briefly 140 degC for sterilisation
Maximum pressure 16 bar at 25 degC; 6 bar at -10 degC and at +140 degC
Temperature probe Pt1000, DIN EN 60751 class A, fast response
Electrical connection 8-pin M12 connector; IP65 when connected; CR-4P cable required
Fitting (immersion) lengths 18 mm (202930/10, total 126 mm); 38 mm (/20, 146 mm); 48 mm (/30, 156 mm)
Wetted materials Cell housing PEEK; electrodes and probe pocket 1.4435 (316L); EPDM seal; FDA-compliant materials
Process connection JUMO PEKA hygienic adapter system; thread M28 x 1.5; O-ring 21 x 2.5 EPDM (not included)
Surface quality Stainless steel components Ra 0.6 um or better; plastic components Ra 0.8 um or better
Order code 202930/10-1005-31-997-83/000: extension 10/20/30; 1005 Pt1000; 31 electrode 316L; 997 PEKA; 83 M12
Stock versions 202930/10-1005-31-997-83/000 part no. 00531113; /20 00531048; /30 00531114
Scope Certificate of quality with exact cell constant, FDA statement for the material and typical surface roughness

Adapters, cables and transmitters

Installation is only possible with JUMO PEKA process connection adapters, which are ordered separately and are made of 1.4435 (316L) with an EN 10204-3.1 certificate: Varivent DN 40 to 125 (00577961), clamp DN 25/32/40 (00577998), clamp DN 50 (00577997), aseptic DN 40 (00577995), aseptic DN 50 (00577979) and aseptic NKS DN 40 (00577999). A spare EPDM O-ring is 00446162. The customer supplies the T-pieces. The datasheet tabulates which fitting length suits which pipe: the short 18 mm design for Varivent and the smaller clamp sizes, the medium and long designs for larger pipes and aseptic fittings, and it recommends checking the cell constant with the transmitter calibration procedure for some clamp combinations.

The cell needs a dedicated 8-pin cable. For the AQUIS 500 CR and dTRANS CR 02 the cable is 00528699 (5 m) or 00528700 (10 m); for the AQUIS touch S/P the versions with extended Pt1000 leads are 00502027 and 00502029; for the digiLine CR ST10 plastic-connector cables of 1.5, 5 and 10 m are 00759427, 00759428 and 00759431. Cable shielding must be connected at the transmitter only, never at the sensor.

Application notes

In operation the transmitter drives an alternating control current through the outer electrode pair and reads the voltage that appears across the inner pair, then calculates conductivity from both. The datasheet notes that supply-line resistances are largely compensated automatically and that measurement errors from contamination or deposits are reduced compared with two-electrode sensors. The standard seal is EPDM, with other materials on request, and every sensor ships with a certificate of quality that states the exact cell constant, FDA compliance of the material and typical surface roughness. Any cell constant deviation from the nameplate value can be adjusted at the transmitter.

The sensor needs no incident flow, but flow is recommended for fast, stable values and to prevent deposits, and it can also be fitted in container walls with at least 18 mm distance to the wall. CIP and SIP capability, reverse-osmosis and ion-exchanger monitoring, phase separation, bottle cleaning and process water are the uses named. For matching instruments see the published AQUIS 500 CR, dTRANS CR 02 and AQUIS touch P; the liquid analysis sensors category lists further conductivity sensors. A good enquiry gives the conductivity span, cleaning chemicals and temperatures, pipe size, hygienic connection standard and the transmitter to be used.

Related JUMO products: JUMO tecLine CR Conductive 2-Electrode Conductivity Sensor, JUMO tecLine Ci-S Inductive Conductivity Sensor, JUMO tecLine Br Amperometric Bromine Sensor, Type 202637, JUMO tecLine Cl2 Free Chlorine Sensor, JUMO ecoLine O-DO Optical Dissolved Oxygen Sensor, Type 202613 and JUMO ecoLine NTU Optical Turbidity Sensor.

Documents and quotation

Hosted for reference is the official JUMO data sheet 202930, version 4.00 dated 2026-05-11, seven pages in English, with dimensions, terminal assignment, order details, stock versions and accessories. Seven Star LLC is an independent supplier in Muscat; send the order code and adapter requirement and we will prepare a quotation. Please include the full order code, the intended medium and the required quantity in your request so that the quotation matches the exact version listed in the data sheet.

Datasheets & Documents
  • PDF Datasheet JUMO tecLine CR-4P data sheet 202930 V4.00 (EN, 7 pages) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.

Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.

JUMO company profile

Established 1948, Fulda, Germany, by Moritz Kurt Juchheim
First products Glass and contact thermometers; platinum glass sensors from 1966
Ownership Family-owned; renamed JUMO GmbH & Co. KG in 2003
Product families RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments

Milestones

  • 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
  • 1966: Platinum glass temperature sensors are added.
  • 2003: The parent company is renamed JUMO GmbH & Co. KG.

JUMO products we list

Family Models Typical use
RTD and thermocouple probes 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp Temperature measurement in pipes, vessels, machines, HVAC and food plants
Thermowells and inserts 909710 thermowells, 909740 measuring inserts Protecting sensors and replacing them without opening the process
Temperature transmitters dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch Converting sensor signals to 4-20 mA, HART or IO-Link
Pressure and level dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 Pressure in process, hydraulic and OEM systems; tank and well level
Controllers, limiters and recorders DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T Furnace, oven and process control, over-temperature protection and recording
Liquid analysis and flow AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 pH, conductivity, oxygen and turbidity in water treatment; liquid flow

Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.

Where JUMO products are used

In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.

Ordering JUMO products: what we need

Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.

Facts checked against JUMO's company history, October 2026.

FAQ

Questions about the JUMO tecLine CR-4P Hygienic Four-Electrode

Answers from our engineering team on installation, compatibility and integration.

01What measuring range does one sensor cover?
Typically about 1 uS/cm to 600 mS/cm; the usable range also depends on the transmitter.
02What are the temperature and pressure limits?
-10 to +120 degC, briefly 140 degC, and 16 bar at 25 degC, falling to 6 bar at -10 and +140 degC.
03Can it be installed without an adapter?
No. Installation is only possible with JUMO PEKA process connection adapters, ordered separately.
04Which transmitters is it compatible with?
AQUIS 500 CR, dTRANS CR 02, AQUIS touch S/P and digiLine CR ST10, each with its own connecting cable.
05Which fitting lengths exist?
18 mm (short), 38 mm (medium) and 48 mm (long), with total lengths of 126, 146 and 156 mm.