Brand:

AUMA SAREx 14.2 Explosion-Proof Modulating Actuator

Description

Overview

AUMA SAREx 14.2 is the fourth SAREx frame and the first on F14: 120 to 250 Nm tripping torque (S4-25 %) with up to 120 / 60 Nm of modulating torque (S4-25 % / S4-50 %).

Seven Star LLC is a trusted supplier of AUMA products for the Sultanate of Oman and the GCC and quotes the SAREx 14.2 as genuine factory product. Gas-processing and utility projects around Sohar and Salalah are served from Muscat. Alternatives and related pages: SAREx range, Ex multi-turn range (SAEx) and AUMA TIGRON TR-M explosion-proof multi-turn actuator.

Operating Principle of the AUMA SAREx 14.2

The SAREx 14.2 is built for intermittent duty, S4-25 % and S4-50 % to class C, so it can follow a controller within the starts limit of 900 per hour at 4 to 11 rpm and 200 per hour at 63 to 90 rpm. The pulse must be at least 70 ms. AMExC or ACExC controls are required to drive the actuator.

Engineering Design of the SAREx 14.2

The SAREx 14.2 allows 900 starts per hour at 4 to 11 rpm but only 200 at 63 to 90 rpm, so a fast control loop should use a slower speed or accept a lower correction rate. The minimum pulse is 70 ms and the weight is 48 to 52 kg, which requires lifting equipment when fitted to elevated control valves.

Cabling uses the Ex plug/socket connector (KT) with spring-clamp control terminals, within an IP68 housing; a 12.5 W motor heater can be added.

Key Features of the AUMA SAREx 14.2

Headline data of the AUMA SAREx 14.2, as documented by AUMA:

  • Trip torque from 120 to 250 Nm for S4-25 % duty, up to 180 Nm for S4-50 %.
  • Modulating torque up to 120 / 60 Nm (S4-25 % / S4-50 %).
  • Output speeds of 4–90 rpm at 50 Hz, with starts graded by speed band.
  • Handwheel diameter 315 mm, approximate weight 48 kg (4–11 rpm), 52 kg (16–90 rpm).
  • 0.12–1.40 kW motors at 400 V; pulse timing 70 ms (same direction); on reversal 280 ms at 4 rpm down to 80 ms at 90 rpm.

Selecting the AUMA SAREx 14.2 for Your Valve

The SAREx 14.2 moves the modulating family to the F14 flange and a 58 mm stem capacity, with 120 to 250 Nm tripping torque. The number of permitted starts depends strongly on speed: 900 per hour from 4 to 11 rpm, 600 from 16 to 22 rpm, 300 from 32 to 45 rpm and 200 from 63 to 90 rpm. Slower speeds therefore allow more frequent positioning, and the speed ratio should be chosen with the control loop in mind.

The SAREx 14.2 doubles the SAREx 10.2 trip ceiling from 120 to 250 Nm, moves to the F14 flange with a 58 mm stem and a 315 mm handwheel and weighs 48 to 52 kg. The SAREx 14.6 doubles it again to 500 Nm on the same flange.

AUMA SAREx 14.2 Modulating Torque and Starts by Speed

AUMA publishes these limits for the AUMA SAREx 14.2 at nominal voltage and +40 °C ambient temperature. Tripping torque is adjustable up to 250 Nm (S4-25 %) or 180 Nm (S4-50 %). Illustrative calculation, not AUMA data: a control valve with 12 turns per stroke needs 180 s at 4 rpm, 33 s at 22 rpm and 8 s at 90 rpm for a full stroke.

rpm (50 Hz) Modulating torque S4-25 / S4-50 %, Nm Max. starts per hour
4–11 120 / 60 900
16–22 120 / 60 600
32–45 120 / 60 300
63–90 100 / 50 200

Loop-tuning note: the SAREx 14.2 has a 70 ms minimum pulse and a reversal pulse from 280 ms (4 rpm) down to 80 ms (90 rpm). The permitted starts fall from 900 to 200 per hour as speed rises, so a loop that needs frequent corrections should use the lower speed bands and accept longer stroke times. A speed of 11 rpm (150 ms on reversal, 900 starts per hour) is a practical upper limit for frequent corrections.

Worked Sizing Example for the SAREx 14.2 (Illustrative Calculation)

A throttling valve on a gas-compression station needs 105 Nm modulating torque. The SAREx 14.2 provides 120 Nm up to 45 rpm and 100 Nm at 63 to 90 rpm, so only speeds up to 45 rpm are acceptable. Among them, 32 to 45 rpm permit 300 starts per hour, while 16 to 22 rpm permit 600, so the control-loop correction rate should be checked before the speed is fixed. This is an illustrative calculation, not AUMA data.

Motor and Electrical Data of the AUMA SAREx 14.2

4 speed points from AUMA’s separate electrical data sheet (S4-25 %, 400 V / 50 Hz), 0.12 to 1.40 kW; approximate values that are not part of the technical datasheet attached here.

rpm Motor type kW IN, A Imax, A IA, A cos φ
4 VDXR090-4-0,12 0.12 0.5 0.8 2.8 0.60
22 VDXR090-2-0,45 0.45 1.5 3.5 9.0 0.64
45 ADXR090-4-0,75 0.75 2.6 5.0 16 0.62
90 ADXR090-2-1,40 1.40 4.7 9.0 38 0.60

Explosion Protection and Installation Notes for the AUMA SAREx 14.2

Standard ATEX markings of the SAREx 14.2 per AUMA: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db. Certificate: DEKRA 11ATEX0008 X. Confirm temperature class and zone on the nameplate.

Where an actuator is delivered as AUMA NORM, AMExC or ACExC controls can be added later. The certificate suffix X marks special conditions of use that must be read in the certificate.

Industrial Applications

The AUMA SAREx 14.2 is used on larger control valves in classified areas, for example inlet and outlet control valves on separators, throttling valves in compressor stations and large level-control valves in storage systems. The stepped starts-per-hour limits help engineers match the actuator to control-loop update rates.

In the Gulf, gas-processing plants and refineries rely on this frame size for continuous modulating duty. Seven Star LLC provides quotations, delivery and technical support for the SAREx 14.2 as a trusted supplier of AUMA products for Oman and the GCC.

Technical Specifications

Core data of the AUMA SAREx 14.2 as published by AUMA; the official data sheet remains binding.

Parameter Specification
Model AUMA SAREx 14.2
Torque range S4-25 % 120–250 Nm
Output speeds 4–90 rpm
Flange / stem F14 / 58 mm
Handwheel / weight 315 mm / 48 kg (4–11 rpm), 52 kg (16–90 rpm)
Gas group IIC
ATEX certificate DEKRA 11ATEX0008 X
Enclosure IP68
Modulating torque 120 / 60 Nm

Neighbouring sizes and counterparts: AUMA SAREx 10.2 explosion-proof modulating actuator, AUMA SAREx 14.6 explosion-proof modulating actuator, AUMA SAEx 14.2 explosion-proof actuator and AUMA SAR 14.2 modulating actuator.

Request a Quote for AUMA SAREx 14.2

Send your RFQ for the AUMA SAREx 14.2 to Seven Star LLC. The technical datasheet can be downloaded from this page, and every unit is backed by AUMA warranty and local support.

Datasheets & Documents
  • PDF Datasheet AUMA SAREx 07.2 - SAREx 16.2 Technical Data Sheet (modulating duty, 3-phase AC) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SAREx 14.2 Explosion-Proof Modulating Actuator

Answers from our engineering team on installation, compatibility and integration.

01What torque and modulating torque does the AUMA SAREx 14.2 offer?
The AUMA SAREx 14.2 has a tripping torque range of 120 to 250 Nm at S4-25 % duty and up to 180 Nm at S4-50 %. The maximum modulating torque is 120 / 60 Nm (S4-25 % / S4-50 %), and on some frames it is reduced at higher output speeds.
02Which flange, stem size and handwheel does the AUMA SAREx 14.2 use?
The AUMA SAREx 14.2 uses an EN ISO 5210 F14 flange (DIN 3210 option G1/2), accepts rising stems up to 58 mm and has a 315 mm handwheel as stated in the data sheet. Approximate weight is 48 kg (4–11 rpm), 52 kg (16–90 rpm).
03What explosion protection does the AUMA SAREx 14.2 carry?
AUMA documents these standard ATEX markings for the AUMA SAREx 14.2: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db, with certificate DEKRA 11ATEX0008 X. This covers gas group IIC; confirm temperature class T4 or T3 and the zone on the supplied nameplate and certificate.
04How often can the AUMA SAREx 14.2 start and what pulse times apply?
The data sheet gives the maximum starts per hour by speed band (4–11 rpm: 900; 16–22 rpm: 600; 32–45 rpm: 300; 63–90 rpm: 200) and the pulse timing as: 70 ms (same direction); on reversal 280 ms at 4 rpm down to 80 ms at 90 rpm. An AMExC or ACExC control is needed to drive the actuator.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so the AUMA SAREx 14.2 is supplied as genuine AUMA product with documentation and regional technical support.