Brand:

AUMA SA 35.1 Multi-Turn Actuator

Description

Overview

AUMA SA 35.1 is an AUMA NORM multi-turn actuator for open-close duty with a tripping-torque window of 2,500 to 8,000 Nm and 10 output speeds from 4 to 90 rpm. SA 35.1 covers 2,500 to 8,000 Nm on an F35 flange and accepts a rising stem up to 155 mm. At 410 to 425 kg it is a unit that needs crane support at installation, and its speed range deliberately stops at 90 rpm.

The SA 35.1 is supplied by Seven Star LLC, a trusted AUMA supplier for Oman and the GCC, together with documentation and a regional contact for commissioning.

Operating Principle

The SA 35.1 counts motor turns for its end positions and trips on torque in each direction from 2,500 to 8,000 Nm. It is self-locking only up to 22 rpm, so faster versions depend on the valve to hold position. Duty is S2 – 15 min as standard and the starts limit is 30 per hour.

Engineering Design of the AUMA SA 35.1

AUMA also publishes separate data for brake-motor and hydraulic-steel-structure versions of the SA 25.1 to SA 40.1 group, which matter where a gate must be held against flow. Output speeds of 4 and 5.6 rpm are available as standard on this size, and the enclosure is IP67 with IP68 optional.

Key Features

Points to weigh when specifying the AUMA SA 35.1:

  • Heavy multi-turn actuator for large hydraulic structures and valves.
  • The tripping torque can be set anywhere between 2,500 and 8,000 Nm, an adjustment span of 3.2 to 1.
  • The S2 – 30 min rating of 5,700 Nm equals 71 percent of the maximum tripping torque.
  • Maximum torque per kilogram of mass is about 18.8 to 19.5 Nm/kg.
  • An illustrative stroke of 100 turns takes about 273 seconds at 22 rpm.
  • It sits above the SA 30.1 and below the SA 40.1 in torque class.
  • AUMA publishes dimension and electrical data sheets for this size separately.

Selecting the AUMA SA 35.1

The speed list of the AUMA SA 35.1 runs from 4 to 90 rpm, ten ratios instead of the twelve of the smaller sizes,. The starts-per-hour limit drops to 30. Torque is 8,000 Nm up to 45 rpm, 6,400 Nm at 63 rpm and 5,500 Nm at 90 rpm in S2-15 min duty. A particular selection point is self-locking: this size is self-locking only up to 22 rpm at 50 Hz, whereas the smaller SA sizes hold position up to 90 rpm, so valves that can be back-driven by flow must be matched to a slow speed or fitted with a brake.

Typical partners are very large gate valves, large radial and wedge sluice gates, penstocks, weir and lock gates, and multi-turn input for large worm or bevel gearboxes in combination with AUMA GK, GST or GS gearbox ranges.

Mounting a 410 to 425 kg actuator is a structural job. The valve manufacturer must confirm that the yoke, the stem and the bonnet flange can carry the weight of the AUMA SA 35.1 together with the reaction torque of up to 8,000 Nm, and often a separate support frame is welded to the valve body. Gate and sluice designers also check the stem for buckling when the thrust that the stem nut applies is high. Seven Star LLC can obtain the AUMA dimension sheet for the SA 25.1 to SA 48.1 range on request. Early agreement on the output drive type, the coupling dimensions and the position of the electrical connection avoids rework at site, where changing any of these on an actuator of this mass is expensive.

Sizing example for the AUMA SA 35.1

Consider an illustrative regulating gate that needs 5,200 Nm at breakaway and 3,000 Nm running. A 25 percent margin gives 6,500 Nm, which is inside the 2,500 to 8,000 Nm window of the AUMA SA 35.1. The full 8,000 Nm is available up to 45 rpm, but only 6,400 Nm at 63 rpm and 5,500 Nm at 90 rpm. A 100-turn stroke at 8 rpm takes about 750 seconds and at 22 rpm about 273 seconds; because the actuator is self-locking only up to 22 rpm the slower speeds are also the safer ones. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SA 35.1

The 410 to 425 kg mass of the AUMA SA 35.1 needs a crane and a verified base frame. The F35 flange takes a rising stem up to 155 mm, and the 400 mm handwheel is relatively small for the torque, so manual operation at the upper end of the range is slow and demanding. Brake-motor versions documented by AUMA for the SA 25.1 to SA 40.1 group can be considered where a gate must be held against flow.

Industrial Applications

Seawater intake screens and gates at the largest desalination and power complexes, bulk-water storage inlets, and dam or flood-control gates are where the AUMA SA 35.1 is found. For Omani projects in Duqm and Sohar where heavy infrastructure is installed, delivery planning should include crane access, a base frame designed for roughly 0.4 tonnes of actuator weight and the handling route to the valve chamber.

Seven Star LLC, a trusted supplier of AUMA products for Oman and the GCC, can combine the SA 35.1 with the AUMA SA 07.2 multi-turn actuator, the AUMA SAR 14.1 multi-turn actuator and the AUMA SAEx explosion-proof actuator.

Neighbouring sizes and counterparts: AUMA SA 30.1 multi-turn actuator, AUMA SA 40.1 multi-turn actuator and AUMA SAEx 35.1 explosion-proof actuator.

Technical Specifications

Data of the AUMA SA 35.1 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SA 35.1
Torque window, S2 – 15 min 2,500 to 8,000 Nm
Ceiling, S2 – 30 min 5,700 Nm
Derating at fast ratios 6,400 Nm at 63 rpm and 5,500 Nm at 90 rpm (S2-15 min); 4,500 Nm and 3,800 Nm (S2-30 min)
Permitted starts per hour 30
Speed range 4 to 90 rpm at 50 Hz, 4.8 to 108 rpm at 60 Hz, 10 steps
Flange EN ISO 5210 F35; DIN 3210 G6
Stem capacity 155 mm
Handwheel size 400 mm
Mass 410 to 425 kg
Protection class IP67 (IP68 optional)
Holds position up to 22 rpm (50 Hz) / 26 rpm (60 Hz)

Setpoint guide for the SA 35.1 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
2,000 2,500
2,600 3,250
3,400 4,250
4,300 5,375
5,300 6,625
6,400 8,000

Stroking time for 100 turns at the SA 35.1 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 100 turns at 50 Hz
4 4.8 1,500
5.6 6.7 1,071
8 9.6 750
11 13 545
16 19 375
22 26 273
32 38 188
45 54 133
63 75 95
90 108 67

Request a Quote for AUMA SA 35.1

To request pricing for the AUMA SA 35.1, give the Seven Star LLC instrumentation division the valve maker, the F35 flange data and the seating torque. The AUMA datasheet is on this page.

Datasheets & Documents
  • PDF Datasheet AUMA SA 25.1 - SA 48.1 Technical Data Sheet (covers AUMA SA 35.1) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SA 35.1 Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SA 35.1?
The tripping torque of the AUMA SA 35.1 is adjustable between 2,500 and 8,000 Nm in S2 - 15 min duty, and the S2 - 30 min maximum is 5,700 Nm. Torque is reduced at the highest speeds: 6,400 Nm at 63 rpm and 5,500 Nm at 90 rpm (S2-15 min); 4,500 Nm and 3,800 Nm (S2-30 min).
02Which output speeds and starts per hour does the AUMA SA 35.1 offer?
The AUMA SA 35.1 offers 10 output speeds from 4 to 90 rpm at 50 Hz and up to 30 starts per hour, and it is self-locking up to 22 rpm (50 Hz) / 26 rpm (60 Hz). An illustrative valve needing 100 turns takes about 273 seconds at 22 rpm.
03Which valve flange and stem size does the AUMA SA 35.1 fit?
The AUMA SA 35.1 uses an EN ISO 5210 F35 flange (DIN 3210 G6 optional) with a rising-stem capacity of 155 mm and a 400 mm handwheel. Special output drives AF, AK, AG, B3D, ED and DD are quoted on request.
04When should I choose the AUMA SA 35.1 instead of a neighbouring size?
Use the AUMA SA 35.1 when valve torque requirements run from roughly 2,500 up to 8,000 Nm. Smaller loads belong on the SA 30.1 (up to 4,000 Nm), while above 8,000 Nm AUMA continues with the SA 40.1 (5,000 to 16,000 Nm, F40) and then the SA 48.1.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SA 35.1 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.