AUMA SAR 30.1 Modulating Multi-Turn Actuator
Description
Overview
AUMA SAR 30.1 is an AUMA NORM multi-turn actuator for modulating duty (class C, ISO 22153) with a tripping-torque window of 2,000 to 4,000 Nm and 4 output speeds from 4 to 11 rpm. SAR 30.1 is the largest modulating actuator of the AUMA SAR range. It delivers 2,000 to 4,000 Nm of tripping torque, 1,600 Nm of modulating torque at S4-25 percent, an F30 flange, a 115 mm stem bore and a 500 mm handwheel.
Customers in Oman and the GCC buy the SAR 30.1 from Seven Star LLC, a trusted supplier of AUMA products, and we confirm weight handling and the F30 interface with them before an order.
Operating Principle
With 2,000 to 4,000 Nm tripping torque, the SAR 30.1 is positioned in short pulses from an AM or AC positioner and holds position by self-locking. Modulating torque is 1,600 Nm (S4 – 25 percent), starts are limited to 300 per hour and the minimum pulse is 100 ms.
Engineering Design of the AUMA SAR 30.1
Modulating torque is 1,600 Nm (S4-25 percent) and 1,400 Nm (S4-50 percent). Standard enclosure protection is IP67 with IP68 optional, and modulating duty is not possible during immersion. The same installation points as the SA 30.1 apply: lifting equipment, structural support for about 190 kg and a separate motor terminal compartment.
Key Features
Points to weigh when specifying the AUMA SAR 30.1:
- Largest modulating SAR actuator, 2,000 to 4,000 Nm.
- Setting window of 2,000–4,000 Nm for OPEN and CLOSE separately, so the top value is 2.0 times the bottom value.
- For S4 – 50 percent operation AUMA permits 2,800 Nm, or 70 percent of the maximum setting.
- Relative to its mass, the maximum torque is about 21.1 Nm for every kilogram.
- An illustrative stroke of 70 turns takes about 525 seconds at 8 rpm.
- The SAR 25.1 is the next size down from here.
- Outline dimensions and motor data are given in AUMA’s separate sheets for this size.
Selecting the AUMA SAR 30.1
The SAR 30.1 mirrors the SA 30.1 mechanically but adds the modulating rating. Output speed is limited to 4, 5.6, 8 and 11 rpm, the number of starts is 300 per hour, the pulse duration is at least 100 ms and the reversal pulse runs from 275 ms at 4 rpm to 130 ms at 11 rpm. The weight is approximately 190 kg. Because no larger SAR size is offered, loads above 4,000 Nm are handled by an AUMA gearbox combination or another actuator family.
Typical partners are very large control gates, heavy regulating valves in water works, level-control sluice gates, and large flow-control valves at power and desalination plants.
The AUMA SAR 30.1 is the end of the SAR range, and above 4,000 Nm AUMA offers solutions with gearboxes or other actuator families. For heavy regulating gates a SAR 30.1 combined with the right controls provides a very stable positioning loop because speeds are low and the gearing is self-locking. Typical commissioning involves a slow stroke over the whole travel to record the position transmitter calibration, followed by a torque trace to confirm that no stroke position exceeds the 1,600 Nm modulating limit at S4-25 percent. Plan one full-stroke run during commissioning with the controller in manual mode, log position feedback against time, and keep that record: it provides the reference stroke time against which later wear or fouling of the gate guides can be recognised.
Sizing example for the AUMA SAR 30.1
Take an illustrative level-control gate that needs 1,500 Nm running torque and 3,400 Nm at the seat. The running torque is under the 1,600 Nm modulating limit at S4-25 percent, and the seat torque lies within the 2,000 to 4,000 Nm window of the AUMA SAR 30.1. An 80-turn stroke at 8 rpm takes 600 seconds and at 11 rpm about 436 seconds, so a 1 percent change of position takes four to six seconds, which makes the actuator slow but accurate for level-control duty. These numbers are an illustrative calculation and not AUMA data.
Installation and Mounting of the AUMA SAR 30.1
At approximately 190 kg the AUMA SAR 30.1 needs crane lifting and a structural check of the valve yoke or gate frame. The F30 flange takes a stem up to 115 mm and the 500 mm handwheel needs wide swing clearance. The motor is wired through terminals in a separate compartment, so plan for heavy-gauge motor cable and a suitable cable gland size, and use the IP68 option where flooding of the gate chamber is possible.
Industrial Applications
The AUMA SAR 30.1 is most relevant to large utility projects: cooling-water flow control in power and desalination stations, bulk-water regulating gates at reservoirs and level-control structures in irrigation and wastewater networks. It is rarely held as a standard item in the region, so early project planning with Seven Star LLC secures a realistic delivery slot.
In Oman and the GCC, Seven Star LLC also supplies the AUMA SAR 14.1 multi-turn actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAREx explosion-proof modulating actuator.
Neighbouring sizes and counterparts: AUMA SAR 25.1 modulating actuator, AUMA SA 30.1 multi-turn actuator and AUMA SAREx 30.1 explosion-proof modulating actuator.
Technical Specifications
Data of the AUMA SAR 30.1 from the AUMA technical data sheet for 3-phase AC motors.
| Parameter | Specification |
|---|---|
| Model | AUMA SAR 30.1 |
| Torque window, S4 – 25 percent | 2,000 to 4,000 Nm |
| Ceiling, S4 – 50 percent | 2,800 Nm |
| Torque while modulating | 1,600 Nm (S4-25%) and 1,400 Nm (S4-50%) |
| Permitted starts per hour | 300 per hour |
| Shortest pulse | 100 ms |
| Reversal delay (maximum) | 275 ms at 4 rpm down to 130 ms at 11 rpm |
| Speed range | 4 to 11 rpm at 50 Hz, 4.8 to 13 rpm at 60 Hz, 4 steps |
| Flange | EN ISO 5210 F30; DIN 3210 G5 |
| Stem capacity | 115 mm |
| Handwheel size | 500 mm |
| Mass | approx. 190 kg |
| Protection class | IP67 (IP68 optional) |
| Holds position | Yes |
Setpoint guide for the SAR 30.1 (illustrative calculation, not AUMA data)
| Breakaway torque (Nm) | Setpoint at +25 percent (Nm) |
|---|---|
| 1,600 | 2,000 |
| 1,800 | 2,250 |
| 2,100 | 2,625 |
| 2,400 | 3,000 |
| 2,800 | 3,500 |
| 3,200 | 4,000 |
Stroking time for 70 turns at the SAR 30.1 (illustrative calculation, not AUMA data)
| rpm at 50 Hz | rpm at 60 Hz | Seconds for 70 turns at 50 Hz |
|---|---|---|
| 4 | 4.8 | 1,050 |
| 5.6 | 6.7 | 750 |
| 8 | 9.6 | 525 |
| 11 | 13 | 382 |
Request a Quote for AUMA SAR 30.1
Contact Seven Star LLC to buy the AUMA SAR 30.1 in the 2,000 to 4,000 Nm class: send valve data and controls, and open the AUMA datasheet from this page.
See also: AUMA SAR 14.6 Modulating Multi-Turn Actuator; AUMA SAR 14.2 Modulating Multi-Turn Actuator; AUMA GS 100.3 Part-Turn Worm Gearbox, 2800 Nm, F14/F16.
Datasheets & Documents
- Datasheet AUMA SAR 25.1 - SAR 30.1 Technical Data Sheet (covers AUMA SAR 30.1) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SAR 30.1 Modulating Multi-Turn Actuator
Answers from our engineering team on installation, compatibility and integration.
01What is the torque range of the AUMA SAR 30.1?
The tripping torque of the AUMA SAR 30.1 is adjustable between 2,000 and 4,000 Nm at S4 - 25 percent and up to 2,800 Nm at S4 - 50 percent.
02What modulating performance does the AUMA SAR 30.1 offer?
The AUMA SAR 30.1 is rated for S4 - 25 percent modulating duty, class C, with a modulating torque of 1,600 Nm (S4-25%) and 1,400 Nm (S4-50%). It allows 300 per hour, with a minimum pulse of 100 ms and a reversal delay of 275 ms at 4 rpm down to 130 ms at 11 rpm.
03Which valve flange and stem size does the AUMA SAR 30.1 fit?
The AUMA SAR 30.1 uses an EN ISO 5210 F30 flange (DIN 3210 G5 optional), accepts a rising stem up to 115 mm and is fitted with a 500 mm handwheel. Weight is approximately 190 kg.
04When should I choose the AUMA SAR 30.1 instead of a neighbouring size?
Select the AUMA SAR 30.1 for valves needing 2,000 to 4,000 Nm with a modulating running torque not above 1,600 Nm at S4-25 percent. For lighter valves the SAR 25.1 (1,000 to 2,000 Nm) is more closely matched, and there is no larger SAR size.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SAR 30.1 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.