Brand:

AUMA SAR 10.2 Modulating Multi-Turn Actuator

Description

Overview

AUMA SAR 10.2 is an AUMA NORM multi-turn actuator for modulating duty (class C, ISO 22153) with a tripping-torque window of 60 to 120 Nm and 10 output speeds from 4 to 90 rpm. SAR 10.2 offers 60 to 120 Nm of tripping torque and up to 60 Nm of modulating torque at S4-25 percent. It is the first SAR size with a dedicated F10 interface and a 40 mm stem bore, supplied with a 200 mm handwheel.

The SAR 10.2 is supplied by Seven Star LLC, a trusted AUMA supplier for Oman and the GCC, with correct documentation and a regional contact for commissioning.

Operating Principle

The SAR 10.2 is positioned by short motor pulses from an AM or AC positioner and keeps its position by self-locking. Modulating torque is 60 Nm (S4 – 25 percent) at 4 to 45 rpm and 50 Nm at 63 to 90 rpm, and a pulse of 50 ms is the minimum.

Engineering Design of the AUMA SAR 10.2

With 1,500 starts per hour up to 45 rpm and 1,200 at 63 and 90 rpm, a minimum pulse duration of 50 ms and a reversal pulse of 60 to 260 ms, the SAR 10.2 comfortably handles loop-controlled positioning. Where a valve is expected to work continuously at the edge of its modulating torque, the S4-50 percent figures should be used instead of the S4-25 percent ones.

Key Features

What stands out on the SAR 10.2:

  • Modulating multi-turn actuator for mid-sized control valves.
  • 60 Nm is the lowest and 120 Nm the highest tripping setting, a 2.0 to 1 range.
  • 90 Nm is the S4 – 50 percent limit, about 75 percent of the largest tripping setting.
  • The torque-to-weight ratio at full setting is 4.8 to 5.5 Nm/kg.
  • An illustrative stroke of 20 turns takes about 54.5 seconds at 22 rpm.
  • Neighbouring frames are the SAR 07.6 and the SAR 14.2.
  • Dimension and electrical data are published by AUMA in separate documents.

Selecting the AUMA SAR 10.2

In the SAR series the AUMA SAR 10.2 is where positioning duty meets mid-sized control valves. The modulating torque is 60 Nm (S4-25 percent) and 45 Nm (S4-50 percent) up to 45 rpm, and 50 Nm and 35 Nm at 63 and 90 rpm. It is slightly heavier than the 07 sizes at 22 to 25 kg. The minimum tripping torque of 60 Nm should be compared with the valve: control valves with a small seat and light packing may need only 25 Nm, in which case a SAR 07.6 is better matched.

Typical partners are globe control valves with larger trim, modulating gate valves, cooling-water and condensate control valves, flow-control valves on pump discharge lines and rising-stem valves in water-treatment filtration plants.

A positioner does not only drive the valve; it also learns how the valve reacts. On the AUMA SAR 10.2 the 60 to 120 Nm tripping window leaves ample margin for torque switching, but the modulating torque of 60 Nm at S4-25 percent is the figure that counts for controller tuning. If the valve plug sticks at low lift, small set-point changes produce no movement until the pulse is long enough, and then the plug jumps. Choosing a lower output speed gives finer steps, which usually improves control quality more than any adjustment of controller gain. Once installed, run a full stroke in both directions under control to record the position transmitter calibration and compare the torque trace with the commissioning values, which gives a baseline for later condition monitoring and for diagnosing a sticking valve.

Sizing example for the AUMA SAR 10.2

Consider an illustrative control valve with a running torque of 48 Nm and a seat torque of 95 Nm. The running torque is below the 60 Nm modulating limit at S4-25 percent (up to 45 rpm), and the seat torque falls within the 60 to 120 Nm window of the AUMA SAR 10.2. At 90 rpm the modulating limit is 50 Nm, still enough, but the S4-50 percent figure there is only 35 Nm, so for heavier duty cycles a slower speed is better. A 20-turn stroke at 16 rpm takes 75 seconds. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SAR 10.2

At 22 to 25 kg the AUMA SAR 10.2 is a one- or two-person lift. The F10 flange is shared with the SA 10.2 and SAR 07.6, so valve brackets are compatible, but the 200 mm handwheel is bigger than on the 07 sizes. Position the actuator so that the plug/socket connector and the controls are accessible, and specify the stem protection tube if the stem protrudes through the actuator.

Industrial Applications

In water-treatment works at Barka, Sohar and Salalah the AUMA SAR 10.2 can control filter-backwash and clarifier outlet valves, while in district-cooling plants it throttles chilled-water bypass and header balancing valves. Power and cogeneration plants use it on desuperheater and condensate return control.

In Oman and the GCC, Seven Star LLC also supplies the AUMA SAR 14.1 multi-turn actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAREx explosion-proof modulating actuator.

Neighbouring sizes and counterparts: AUMA SAR 07.6 modulating actuator, AUMA SAR 14.2 modulating actuator, AUMA SA 10.2 multi-turn actuator and AUMA SAREx 10.2 explosion-proof modulating actuator.

Technical Specifications

Data of the AUMA SAR 10.2 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SAR 10.2
Setting range, S4 – 25 percent 60 to 120 Nm
Top torque S4 – 50 percent 90 Nm
Running torque limit 60 Nm (S4-25%) and 45 Nm (S4-50%) up to 45 rpm, reducing to 50 Nm and 35 Nm at 63 and 90 rpm
Start limit per hour 1,500 per hour (1,200 per hour at 63 and 90 rpm)
Pulse duration, minimum 50 ms
Delay after reversal 260 ms at 4 rpm down to 60 ms at 90 rpm
Available speeds 4 to 90 rpm at 50 Hz, 4.8 to 108 rpm at 60 Hz, 10 steps
Valve interface EN ISO 5210 F10; DIN 3210 G0
Largest rising stem 40 mm
Handwheel diameter 200 mm
Approximate weight 22 to 25 kg
Ingress protection IP68
Self-locking range Yes

Setpoint guide for the SAR 10.2 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
50 63
55 69
65 81
75 94
85 106
95 119

Stroking time for 20 turns at the SAR 10.2 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 20 turns at 50 Hz
4 4.8 300
5.6 6.7 214
8 9.6 150
11 13 109
16 19 75
22 26 55
32 38 38
45 54 27
63 75 19
90 108 13

Ordering details for SAR 10.2

The SAR 10.2 technical data lists the valve mounting arrangement as F10 (ISO 5210), DIN 3210 G0. Identify the modulating duty, starts per hour and output speed at the installation frequency on the enquiry.

Technical reference

Request a Quote for AUMA SAR 10.2

Planning a regulating loop with the AUMA SAR 10.2? Send Seven Star LLC your quantities, supply voltage and controls, then open the AUMA datasheet from this page.

Datasheets & Documents
  • PDF Datasheet AUMA SAR 07.2 - SAR 16.2 Technical Data Sheet (covers AUMA SAR 10.2) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SAR 10.2 Modulating Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SAR 10.2?
The tripping torque of the AUMA SAR 10.2 is adjustable between 60 and 120 Nm at S4 - 25 percent and up to 90 Nm at S4 - 50 percent.
02What modulating performance does the AUMA SAR 10.2 offer?
The AUMA SAR 10.2 is rated for S4 - 25 percent modulating duty, class C, with a modulating torque of 60 Nm (S4-25%) and 45 Nm (S4-50%) up to 45 rpm, reducing to 50 Nm and 35 Nm at 63 and 90 rpm. It allows 1,500 per hour (1,200 per hour at 63 and 90 rpm), with a minimum pulse of 50 ms and a reversal delay of 260 ms at 4 rpm down to 60 ms at 90 rpm.
03Which valve flange and stem size does the AUMA SAR 10.2 fit?
The AUMA SAR 10.2 uses an EN ISO 5210 F10 flange (DIN 3210 G0 as an option), takes a rising stem up to 40 mm and has a 200 mm handwheel.
04When should I choose the AUMA SAR 10.2 instead of a neighbouring size?
Choose the AUMA SAR 10.2 when the valve's maximum torque is about 60 to 120 Nm and the running torque during modulation stays within 60 Nm. The SAR 07.6 handles 30 to 60 Nm, and the SAR 14.2 on the F14 flange covers 120 to 250 Nm.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SAR 10.2 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.