Brand: AUMA
AUMA SAREx 07.6 Explosion-Proof Modulating Actuator
Description
Overview
AUMA SAREx 07.6 is the second SAREx frame, with 30 to 60 Nm tripping torque (S4-25 %) and up to 30 / 15 Nm modulating torque (S4-25 % / S4-50 %) on an F07 / F10 flange.
Seven Star LLC quotes the SAREx 07.6 as trusted AUMA supplier for Oman and the GCC, with documentation suited to ATEX project files. Our Muscat office supports consultants and EPC contractors in Sohar and Salalah. See also the SAREx series overview, the SAEx explosion-proof actuators and the AUMA SDL/SDG variable-speed actuator.
Operating Principle of the AUMA SAREx 07.6
The SAREx 07.6 is built for intermittent duty, S4-25 % and S4-50 % to class C, so it can follow a controller continuously within its starts limit of 1,200 per hour up to 45 rpm. Pulses start from 50 ms, and a reversal needs up to 260 ms at 4 rpm. AMExC or ACExC controls drive the actuator.
Engineering Design of the SAREx 07.6
For the SAREx 07.6, match the controller’s deadband to the 50 ms minimum pulse so the actuator does not hunt around the setpoint. With 30 Nm of modulating torque up to 45 rpm and 20 Nm above, check that the control-valve friction stays below these values, and verify the 22 to 24 kg weight against the valve’s support.
Connection follows the same pattern as the SAREx 07.2: an Ex plug/socket connector (KT), spring-clamp control terminals, IP68 enclosure and an optional 12.5 W heater.
Key Features of the AUMA SAREx 07.6
Data points that matter most when specifying the AUMA SAREx 07.6:
- A torque window of 30–60 Nm (S4-25 %); the S4-50 % ceiling is 40 Nm.
- Maximum modulating torque of 30 / 15 Nm (S4-25 % / S4-50 %).
- Output speeds of 4–90 rpm at 50 Hz, with starts graded by speed band.
- Handwheel diameter 160 mm, approximate weight 22 kg (4–22 rpm), 24 kg (32–90 rpm).
- Motor power of 0.03–0.40 kW at 400 V; pulse timing 50 ms (same direction); on reversal 260 ms at 4 rpm down to 60 ms at 90 rpm.
Selecting the AUMA SAREx 07.6 for Your Valve
The SAREx 07.6 doubles the torque capability of the 07.2 to 60 Nm (S4-25%) while retaining the F07/F10 flange and 160 mm handwheel. Its modulating torque is 30 Nm (S4-25%) and 15 Nm (S4-50%) up to 45 rpm, then 20 Nm and 10 Nm from 63 rpm to 90 rpm. Choose it when a small control valve needs more positioning force than the 07.2 offers, but a move to the F10-only 10.2 would be unnecessary.
Compared with the SAREx 07.2, the SAREx 07.6 doubles the trip ceiling from 30 to 60 Nm and the modulating torque from 15 to 30 Nm at 4 to 45 rpm. The step up to the SAREx 10.2 brings 120 Nm and a 200 mm handwheel.
AUMA SAREx 07.6 Modulating Torque and Starts by Speed
These are the modulating limits of the AUMA SAREx 07.6 by output speed, valid at nominal voltage and +40 °C. Tripping torque is adjustable up to 60 Nm (S4-25 %) or 40 Nm (S4-50 %). Illustrative calculation, not AUMA data: a control valve with 8 turns per stroke needs 86 s at 5.6 rpm, 15 s at 32 rpm and 8 s at 63 rpm for a full stroke.
| Speed, rpm at 50 Hz | Permitted modulating torque (S4-25 / S4-50 %), Nm | Starts per hour, max. |
|---|---|---|
| 4–45 | 30 / 15 | 1,200 |
| 63–90 | 20 / 10 | 900 |
Loop-tuning note: the SAREx 07.6 shares the 50 ms minimum pulse and the 260 to 60 ms reversal-pulse range of the 07.2, but offers higher modulating torque (30 Nm up to 45 rpm). For a loop that updates every few seconds, 11 to 22 rpm (130 to 90 ms on reversal) usually gives enough resolution without using more of the 1,200 starts per hour than necessary. Controllers should avoid reversing direction more often than the process requires.
Worked Sizing Example for the SAREx 07.6 (Illustrative Calculation)
A fuel-gas pressure control valve has a friction torque of 25 Nm. The SAREx 07.6 provides 30 Nm modulating torque at S4-25 % up to 45 rpm, but only 20 Nm at 63 to 90 rpm, so the slower speed bands are required. At 4 to 45 rpm the permitted 1,200 starts per hour support even demanding control loops, while at 63 to 90 rpm the limit is 900. This is an illustrative calculation, not AUMA data.
Motor and Electrical Data of the AUMA SAREx 07.6
4 speed points from AUMA’s separate electrical data sheet (S4-25 %, 400 V / 50 Hz), 0.03 to 0.40 kW; approximate values that are not part of the technical datasheet attached here.
| Output rpm | Type | PN, kW | IN (A) | Imax (A) | IA (A) | cos φ |
|---|---|---|---|---|---|---|
| 4 | VDXR063-4-0,03 | 0.03 | 0.4 | 0.5 | 1.0 | 0.43 |
| 22 | VDXR063-2-0,12 | 0.12 | 0.7 | 1.0 | 3.0 | 0.52 |
| 45 | ADXR063-4-0,20 | 0.20 | 1.6 | 2.0 | 4.6 | 0.42 |
| 90 | ADXR063-2-0,40 | 0.40 | 1.8 | 2.5 | 9.0 | 0.53 |
Explosion Protection and Installation Notes for the AUMA SAREx 07.6
Standard ATEX markings of the SAREx 07.6 per AUMA: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db. Certificate: DEKRA 11ATEX0008 X. Confirm temperature class and zone on the nameplate.
Humidity of up to 100 % relative is permitted across the whole temperature range, and the standard ambient range is minus 30 °C to plus 40 °C or plus 60 °C. The certificate suffix X flags special conditions of use.
Industrial Applications
The AUMA SAREx 07.6 suits small to medium control valves in hazardous areas, including separator level control, fuel-gas pressure control and chemical-dosing control. Its 30 Nm modulating torque at S4-25% is sufficient for most small globe-type control valves.
In gathering stations and process skids across the Sultanate, this size is a common step above the 07.2. Seven Star LLC quotes the SAREx 07.6 with local technical support and genuine AUMA documentation for Oman and the GCC.
Technical Specifications
Key figures for the AUMA SAREx 07.6, taken from AUMA’s technical data sheet.
| Item | Value |
|---|---|
| Model | AUMA SAREx 07.6 |
| Torque range S4-25 % | 30–60 Nm |
| Output speeds | 4–90 rpm |
| Flange / stem | F07 / F10 / 26 / 34 mm |
| Handwheel / weight | 160 mm / 22 kg (4–22 rpm), 24 kg (32–90 rpm) |
| Gas group | IIC |
| ATEX certificate | DEKRA 11ATEX0008 X |
| Enclosure | IP68 |
| Modulating torque | 30 / 15 Nm |
Neighbouring sizes and counterparts: AUMA SAREx 07.2 explosion-proof modulating actuator, AUMA SAREx 10.2 explosion-proof modulating actuator, AUMA SAEx 07.6 explosion-proof actuator and AUMA SAR 07.6 modulating actuator.
Request a Quote for AUMA SAREx 07.6
Send your RFQ for the AUMA SAREx 07.6 to Seven Star LLC, naming valve, torque and positioner needs. The datasheet can be downloaded here and every unit ships with warranty.
Datasheets & Documents
- Datasheet AUMA SAREx 07.2 - SAREx 16.2 Technical Data Sheet (modulating duty, 3-phase AC) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SAREx 07.6 Explosion-Proof Modulating Actuator
Answers from our engineering team on installation, compatibility and integration.
01What torque and modulating torque does the AUMA SAREx 07.6 offer?
The AUMA SAREx 07.6 has a tripping torque range of 30 to 60 Nm at S4-25 % duty and up to 40 Nm at S4-50 %. The maximum modulating torque is 30 / 15 Nm (S4-25 % / S4-50 %), and on some frames it is reduced at higher output speeds.
02Which flange, stem size and handwheel does the AUMA SAREx 07.6 use?
The AUMA SAREx 07.6 uses an EN ISO 5210 F07 / F10 flange (DIN 3210 option G0 with F10), accepts rising stems up to 26 mm (34 mm with F10) and has a 160 mm handwheel as stated in the data sheet. Approximate weight is 22 kg (4–22 rpm), 24 kg (32–90 rpm).
03What explosion protection does the AUMA SAREx 07.6 carry?
AUMA documents these standard ATEX markings for the AUMA SAREx 07.6: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db, with certificate DEKRA 11ATEX0008 X. This covers gas group IIC; confirm temperature class T4 or T3 and the zone on the supplied nameplate and certificate.
04How often can the AUMA SAREx 07.6 start and what pulse times apply?
The data sheet gives the maximum starts per hour by speed band (4–45 rpm: 1,200; 63–90 rpm: 900) and the pulse timing as: 50 ms (same direction); on reversal 260 ms at 4 rpm down to 60 ms at 90 rpm. An AMExC or ACExC control is needed to drive the actuator.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so the AUMA SAREx 07.6 is supplied as genuine AUMA product with documentation and regional technical support.


















Reviews