Brand:

AUMA SA 40.1 Multi-Turn Actuator

Description

Overview

AUMA SA 40.1 is an AUMA NORM multi-turn actuator for open-close duty with a tripping-torque window of 5,000 to 16,000 Nm and 8 output speeds from 4 to 45 rpm. SA 40.1 sits near the top of the AUMA SA range with 5,000 to 16,000 Nm, an F40 flange and a rising stem capacity of 175 mm. It weighs about 510 kg and is limited to 20 starts per hour.

Customers in Oman and the GCC buy the AUMA SA 40.1 from Seven Star LLC, a trusted supplier of AUMA products, and our team checks stem size and weight handling before the order is placed.

Operating Principle

At the top of this multi-turn range, the SA 40.1 still counts motor turns for its OPEN and CLOSED end positions and trips on torque from 5,000 to 16,000 Nm. Self-locking applies up to 22 rpm, the speed list ends at 45 rpm, and S2 – 15 min duty allows 20 starts per hour.

Engineering Design of the AUMA SA 40.1

The unit is supplied with a 500 mm handwheel and, like other SA 25.1 and larger sizes, with IP67 standard protection and IP68 as an option. Brake-motor and hydraulic-steel-structure variants for SA 25.1 to SA 40.1 are documented separately by AUMA and should be requested when a gate has to be held in position against differential pressure.

Key Features

What stands out on the AUMA SA 40.1:

  • Extra-heavy multi-turn actuator for the largest gates and valves.
  • Adjustment range: 5,000 to 16,000 Nm per direction, a ratio of 3.2 to 1 between lowest and highest setting.
  • Under S2 – 30 min duty the limit is 11,200 Nm, which is 70 percent of the top tripping value.
  • Power density works out at roughly 31.4 Nm of maximum torque per kilogram.
  • An illustrative stroke of 120 turns takes about 450 seconds at 16 rpm.
  • The SA 35.1 is the next size down from here.
  • Dimension drawings and electrical data are covered by separate AUMA sheets.

Selecting the AUMA SA 40.1

This size has the narrowest speed list of the whole SA family: eight ratios from 4 to 45 rpm. Torque at S2-15 min is 16,000 Nm up to 22 rpm, 14,000 Nm at 32 rpm and 10,000 Nm at 45 rpm, with S2-30 min values of 11,200, 9,800 and 7,000 Nm. Anyone converting a valve stroke into an actuation time should use the examples in this page; at 22 rpm a valve needing 120 turns takes about five and a half minutes. Like the SA 35.1 this size is self-locking only up to 22 rpm at 50 Hz.

Typical partners are very large sluice and radial gates, big wedge-gate valves in penstock lines, hydraulic steel structures, and multi-turn input for heavy gearboxes that drive very large butterfly or ball valves.

With only eight speeds, from 4 to 45 rpm, the AUMA SA 40.1 is selected almost entirely on torque and stroke time. A radial or sector gate needing 120 turns will take more than five minutes at 22 rpm, and the operator should confirm that the hydraulic or civil design tolerates that closing time. For installations where the gate must be closed in an emergency, the control philosophy should include a stand-by supply, because manual operation at this torque level is slow and the handwheel is intended for setting and emergency strokes. Ask for the outline drawing and the weight certificate of the ordered configuration, and share them with the structural engineer and the lifting contractor well ahead of delivery, because every option adds mass and changes the centre of gravity.

Sizing example for the AUMA SA 40.1

For an illustrative radial gate that needs 11,000 Nm to break away and 6,500 Nm to run, a 25 percent margin gives about 13,750 Nm. That is within the 5,000 to 16,000 Nm window of the AUMA SA 40.1, and the 16,000 Nm rating applies up to 22 rpm, with 14,000 Nm at 32 rpm and 10,000 Nm at 45 rpm. At 45 rpm the actuator would therefore be undersized for this duty. A 120-turn stroke at 11 rpm takes about 655 seconds and at 22 rpm about 327 seconds. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SA 40.1

At approximately 510 kg the AUMA SA 40.1 is lifted only with certified lifting gear, and the yoke, base frame and civil structure must be verified for the weight, the 16,000 Nm reaction torque and the stem load. The F40 flange takes a stem up to 175 mm and the 500 mm handwheel provides only a limited manual capability at this torque level, so emergency operating procedures should rely on a power tool or a stand-by supply.

Industrial Applications

Applications in the Gulf include the largest seawater intake and outfall gates, bulk-water transfer penstocks and storm-water structures. Because few Omani projects need this torque class, early engineering review with the valve manufacturer is advisable so that the valve stem, yoke and civil structure are verified for the actuator’s reaction forces before purchase.

For heavy valve projects, a trusted supplier of AUMA products Seven Star LLC offers the AUMA SA 10.2 multi-turn electric actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAEx explosion-proof actuator in Oman and the GCC.

Neighbouring sizes and counterparts: AUMA SA 35.1 multi-turn actuator and AUMA SAEx 40.1 explosion-proof actuator.

Technical Specifications

Data of the AUMA SA 40.1 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SA 40.1
Setting range, S2 – 15 min 5,000 to 16,000 Nm
Top torque S2 – 30 min 11,200 Nm
Torque loss at top speeds 14,000 Nm at 32 rpm and 10,000 Nm at 45 rpm (S2-15 min); 9,800 Nm and 7,000 Nm (S2-30 min)
Start limit per hour 20
Available speeds 4 to 45 rpm at 50 Hz, 4.8 to 54 rpm at 60 Hz, 8 steps
Valve interface EN ISO 5210 F40; DIN 3210 G7
Largest rising stem 175 mm
Handwheel diameter 500 mm
Approximate weight approx. 510 kg
Ingress protection IP67 (IP68 optional)
Self-locking range up to 22 rpm (50 Hz) / 26 rpm (60 Hz)

Setpoint guide for the SA 40.1 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
4,000 5,000
5,200 6,500
6,800 8,500
8,600 10,750
10,700 13,375
12,800 16,000

Stroking time for 120 turns at the SA 40.1 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 120 turns at 50 Hz
4 4.8 1,800
5.6 6.7 1,286
8 9.6 900
11 13 655
16 19 450
22 26 327
32 38 225
45 54 160

Request a Quote for AUMA SA 40.1

Ask Seven Star LLC for a quotation on the AUMA SA 40.1: send valve torque, F40 flange details, stem size and site conditions, and download the AUMA datasheet from this page.

Datasheets & Documents
  • PDF Datasheet AUMA SA 25.1 - SA 48.1 Technical Data Sheet (covers AUMA SA 40.1) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SA 40.1 Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SA 40.1?
The tripping torque of the AUMA SA 40.1 is adjustable between 5,000 and 16,000 Nm in S2 - 15 min duty, and the S2 - 30 min maximum is 11,200 Nm. Torque is reduced at the highest speeds: 14,000 Nm at 32 rpm and 10,000 Nm at 45 rpm (S2-15 min); 9,800 Nm and 7,000 Nm (S2-30 min).
02Which output speeds and starts per hour does the AUMA SA 40.1 offer?
The AUMA SA 40.1 offers 8 output speeds from 4 to 45 rpm at 50 Hz and up to 20 starts per hour, and it is self-locking up to 22 rpm (50 Hz) / 26 rpm (60 Hz). An illustrative valve needing 120 turns takes about 450 seconds at 16 rpm.
03Which valve flange and stem size does the AUMA SA 40.1 fit?
The AUMA SA 40.1 is built for an EN ISO 5210 F40 flange (DIN 3210 G7 optional) and accepts a rising stem up to 175 mm in diameter. The handwheel diameter is 500 mm and the weight is approximately 510 kg.
04When should I choose the AUMA SA 40.1 instead of a neighbouring size?
Select the AUMA SA 40.1 for torque demands between about 5,000 and 16,000 Nm. For lighter loads the SA 35.1 (2,500 to 8,000 Nm) is lower in weight, and for heavier loads the SA 48.1 extends to 32,000 Nm on an F48 flange.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SA 40.1 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.