Brand:

AUMA ACExC 01.2 Explosion-Proof Actuator Controls

Description

Overview

The AUMA ACExC 01.2 (AUMATIC) is the explosion-proof, microprocessor-based actuator control unit from AUMA Riester, designed for plants where potentially explosive atmospheres are likely to occur. It is mounted directly onto SAEx/SAREx multi-turn actuators and SQEx/SQREx part-turn actuators and combines integral local controls, motor switchgear, status signalling and fieldbus communication in a single flameproof housing that cannot act as an ignition source. The unit evaluates operating commands and actuator feedback signals and switches the actuator motor without delay, so that only commands and feedback need to travel between the plant control system and the valve.

In Oman and the GCC, Seven Star LLC proudly supplies the AUMA ACExC 01.2 to customers across the Sultanate of Oman and the wider GCC. Our team supports engineers and procurement leads from specification through delivery, including selection of voltage, fieldbus and certification options for the Omani oil, gas and petrochemical sector.

Operating Principle of the AUMA ACExC 01.2

The AUMA ACExC 01.2 sits between the control system and the actuator motor. Operating commands arrive through six opto-isolated digital inputs (OPEN, STOP, CLOSE and EMERGENCY), through a 0/4–20 mA analogue setpoint when the positioner option is fitted, or through a fieldbus interface. The controls compare these commands with the position and torque signals delivered by the actuator and then switch the motor via mechanically and electrically interlocked reversing contactors or, for modulating duty, a thyristor unit. Seating can be selected as limit or torque seating independently for the OPEN and CLOSED end positions, and a torque bypass with adjustable duration allows high break-away torques during start-up.

In combination with the MWG magnetic limit and torque transmitter, the AUMA ACExC 01.2 offers non-intrusive setting of the actuator: limit and torque switching points are parametrised through the local controls without opening the explosion-proof enclosure. The controls also derive two galvanically isolated analogue outputs for position and torque, store up to three torque-travel characteristics per direction, and monitor phase sequence, motor temperature, heater, operation time and number of starts. Faults and maintenance needs are reported in line with NAMUR recommendation NE 107.

Engineering Design of the AUMA ACExC 01.2

The housing of the AUMA ACExC 01.2 is built for flameproof Ex de protection as standard (II2G Ex de IIC T4 or T3 Gb, II2D Ex tb IIIC T130 °C or T190 °C Db IP6x), with an Ex d option. Enclosure protection is IP68 and the corrosion protection class is KS, suitable for coastal and highly saline atmospheres. The permissible ambient temperature range is −30 °C to +40/+60 °C. The local controls provide a selector switch LOCAL – OFF – REMOTE that can be locked in all three positions, push buttons for OPEN, STOP, CLOSE and RESET, six indication lights including a Bluetooth indicator, and an illuminated graphic LC display that supports status monitoring and parametrisation.

Electrical connection is made through the AUMA Ex plug/socket connector (KT) with screw-type motor terminals and push-in control terminals; terminal-block versions (KES) are available for increased safety Ex e or flameproof Ex d. The controls can be mounted integrally on the actuator or separately on a wall bracket, and an external 24 V DC supply of the electronics is available as an option so that the control logic remains alive when the mains supply is switched off. Cable entries are offered in metric as standard, with Pg, NPT and G threads as options.

Key Features

The following features make the AUMA ACExC 01.2 the reference control platform for hazardous-area valve automation:

  • Explosion protection to ATEX with DEKRA certificates for combination with SAEx and SQEx actuators, plus FM and IECEx approvals for international installations.
  • Illuminated graphic LC display and lockable local controls give operators clear status information and safe local operation directly at the valve.
  • Bluetooth 4.2 interface with a range of up to 10 m allows commissioning and diagnostics from a notebook or Android and iOS device through the AUMA CDT and AUMA Assistant App.
  • Optional positioner and PID process controller accept 0/4–20 mA setpoints, with programmable behaviour on loss of signal, split-range operation and adaptive dead band.
  • Fieldbus control via Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, Foundation Fieldbus, HART and WirelessHART, including component-redundant interfaces and FOC connection.
  • Programmable EMERGENCY behaviour, interlock functions and Partial Valve Stroke Test (PVST) to verify actuator and controls on demand.
  • Comprehensive operating data logging with resettable and lifetime counters and a time-stamped event report with history.
  • Safe end position feedback up to SIL 2 in selected configurations, with a dedicated SIL version available for safety instrumented functions.

Industrial Applications

Hazardous-area valve automation is a daily reality for oil and gas, petrochemical and LNG operators in the Sultanate of Oman. The AUMA ACExC 01.2 is a natural fit for tank farms, pipeline manifolds, refinery process units and offshore-supply terminals around Sohar, Duqm and Salalah, where ESD valves, isolation valves and modulating control valves must be operated from the control room yet remain fully operable locally. Its thyristor option suits modulating duty on process control valves, while the standard reversing contactors serve open–close isolation service. In coastal installations the KS corrosion protection and IP68 enclosure withstand salt-laden air and extended exposure to humidity.

In Oman and the GCC, Seven Star LLC supplies the AUMA ACExC 01.2 together with matching SAEx and SQEx actuators, wall brackets and cable sets, plug/socket connectors and commissioning tools for refineries, gas processing plants, fertiliser and chemical complexes, and the Muscat and Sohar industrial zones. Water and power utilities with hazardous classified areas, such as biogas, fuel storage and chlorine handling, also rely on explosion-proof controls of this type. For projects that combine the AUMA ACExC 01.2 with other drives or controls, Seven Star LLC also supplies the AUMA MATIC AM/AC integral actuator controls, the AUMA AMExC 01.1 and the AUMA SAEx explosion-proof actuator.

Technical Specifications

The table summarises the main data of the AUMA ACExC 01.2 as published in the AUMA technical data sheet; the complete data sheet is available for download on this page.

Parameter Specification
Model AUMA ACExC 01.2 (AUMATIC explosion-proof actuator controls)
Suitable actuators SAEx/SAREx .1 and .2 multi-turn; SQEx/SQREx .2 part-turn
Explosion protection (standard) II2G Ex de IIC T4 or T3 Gb; II2D Ex tb IIIC T130 °C or T190 °C Db IP6x; option II2G Ex d IIC T4 or T3 Gb
Certificates DEKRA 11ATEX0008 X (with SAEx); DEKRA 13ATEX0016 X (with SQEx); FM and IECEx listings are shown on the AUMA product page, not on the data sheet
Mains voltage 3-phase 220–690 V AC and 1-phase 110–240 V AC (standard and special voltages); DC 24/110/220 V for selected actuators; tolerance ±10 % (±30 % option)
Switchgear Reversing contactors for AUMA power classes A1/A2 (A3 option); thyristor unit up to 600 V AC for classes B1, B2, B3
Control inputs 6 digital inputs (OPEN, STOP, CLOSE, EMERGENCY); 24 V DC standard, other control voltages optional
Output signals 6 programmable contacts as standard (5 NO and 1 change-over); up to 12 optional
Analogue interfaces 2 isolated outputs 0/4–20 mA with MWG; 2 inputs 0/4–20 mA with positioner option
Communication Bluetooth 4.2 + EDR; fieldbus options as listed above
Enclosure / corrosion protection IP68 / KS
Ambient temperature −30 °C to +40/+60 °C
Electrical connection AUMA Ex plug/socket connector (KT); KES terminal-block versions optional

Request a Quote for AUMA ACExC 01.2

To request a formal quotation for the AUMA ACExC 01.2, submit an RFQ through this page with the actuator type, supply voltage, required fieldbus interface and hazardous-area classification. Seven Star LLC can confirm availability and lead time, arrange matching AUMA actuators and accessories, and provide the technical datasheet for download. Contact our instrumentation division in Muscat for engineering support. In Oman and the GCC, Seven Star LLC supplies products on request with local technical support.

Datasheets & Documents
  • PDF Datasheet AUMA ACExC 01.2 Technical Data Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA ACExC 01.2 Explosion-Proof Actuator Controls

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between the AUMA ACExC 01.2 and the standard AC 01.2 controls?
The ACExC 01.2 is the explosion-proof version of the AUMATIC platform. It offers the same microprocessor functions, display, Bluetooth interface and fieldbus options, but in a flameproof Ex de (Ex d optional) housing certified under ATEX, IECEx and FM for hazardous areas, and it is combined with SAEx/SAREx and SQEx/SQREx actuators.
02Can the AUMA ACExC 01.2 be mounted away from the actuator?
Yes. The controls can be fitted integrally on the actuator or mounted separately on a wall bracket, which is useful where the valve is difficult to reach or exposed to strong vibration or high ambient temperature. AUMA states a maximum permissible distance of 100 metres when wall brackets and cable sets are used.
03Which fieldbus protocols does the AUMA ACExC 01.2 support?
Control options include Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, Foundation Fieldbus, HART and WirelessHART. Interfaces are also available in a component-redundant design, and fibre-optic connection is possible for fieldbus interfaces.
04Does the AUMA ACExC 01.2 support functional safety?
In selected configurations the standard unit provides safe end position feedback up to SIL 2. For safety instrumented functions such as safe ESD, a separate ACExC 01.2-SIL version with an additional certified SIL module is available.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC is the trusted supplier for AUMA in Oman and the GCC and supplies genuine AUMA actuators, controls, gearboxes and accessories with local technical support from Muscat.