Brand:

AUMA SQ 05.2 Part-Turn Electric Actuator

Description

Overview

AUMA SQ 05.2 is the smallest frame size of the SQ .2 part-turn actuator range, and it is the drive AUMA positions for valves that need a moderate quarter-turn torque rather than the heavy output of the larger frames. The tripping torque can be adjusted between 50 Nm and 150 Nm in both directions, which places the actuator squarely in the territory of small ball valves, plug valves, dampers and compact butterfly valves. Because the SQ 05.2 shares its housing concept with the rest of the range, the controls, accessories and documentation you learn on this size carry over unchanged if a later project moves up a frame.

In Oman and the GCC, Seven Star LLC proudly supplies the AUMA SQ 05.2 to customers in the Sultanate of Oman and the wider GCC. Our instrumentation team helps buyers in Muscat, Sohar and Salalah confirm the valve torque, the F05 or F07 flange pattern and the required operating time before an order is placed, so the actuator that arrives matches the valve it is meant to move.

Quarter-Turn Drive Logic

Inside the AUMA SQ 05.2 a three-phase squirrel-cage motor drives a worm gear stage, and the final stage delivers a rotation of roughly a quarter turn to a splined output coupling. The swing angle is adjustable between 75 degrees and just under 105 degrees as standard, with further ranges available as options for valves that need a shorter or longer stroke. Limit switching uses a counter gear mechanism, and the torque switching can be set separately for the OPEN and CLOSE directions inside the 50 to 150 Nm window.

One of the distinguishing numbers for this size is the span of operating times. AUMA lists eight selectable times for a 90 degree stroke at 50 Hz, running from a very quick 4 seconds up to a slow 63 seconds. The fast end suits process valves that must react promptly, while the slow end limits pressure surges on water lines where a rapid closure would cause hydraulic shock. The motor behind these choices is small, with rated power between 0.01 kW and 0.06 kW depending on the speed selected, and the AUMA SQ 05.2 is self-locking when the valve cannot be moved from standstill.

Engineering Design of the AUMA SQ 05.2

The housing of the AUMA SQ 05.2 accepts valve flanges to EN ISO 5211 in size F05 or F07 as standard, with F10 available as an option. A splined coupling transmits the torque and can be supplied unbored for machining on site, or bored with a keyway, square or two-flat profile. The maximum shaft diameters are 25.4 mm cylindrical, 22 mm square and 22 mm across flats, which fits typical small ball valve stems. A 160 mm handwheel allows emergency and setting operation and needs 11 or 16 turns for a full 90 degrees depending on the gear ratio chosen with the operating time.

At about 21 kg including the unbored coupling and handwheel, or about 27 kg with the optional base and lever, the SQ 05.2 is light enough for straightforward installation on pipe racks, skids and walkways. A 1-phase AC version is documented at roughly 23 kg, and AUMA also lists DC motor versions of this size with operating times between 3.5 s and 18.5 s for supply systems without an AC grid. Enclosure protection is IP68 and the standard coating system is KS, intended for high salinity and almost permanent condensation, which is relevant for coastal installations along the Gulf of Oman.

Key Features

The key strengths of the AUMA SQ 05.2 come from the way a small body is combined with the same protection and control options as larger AUMA drives.

  • A tripping torque range of 50 Nm to 150 Nm gives a clear fit for small quarter-turn valves without oversizing the drive.
  • Eight selectable operating times from 4 s to 63 s for 90 degrees let the closing speed be matched to the line, from fast process isolation to surge-free water service.
  • F05/F07 valve attachment with an F10 option covers the flange patterns found on compact ball and butterfly valves.
  • Standard swing angle adjustment from 75 to below 105 degrees, with optional ranges, supports non-standard valve strokes.
  • A 160 mm handwheel enables manual setting and emergency operation without electrical power.
  • IP68 enclosure protection and KS corrosion protection suit outdoor, humid and coastal installation.
  • Single or tandem limit and torque switches, plus optional position feedback by potentiometer or 0/4-20 mA transmitter, serve basic and advanced control schemes.
  • AM and AC actuator controls can be added later, so a plant can start with simple switching and move to fieldbus control without replacing the actuator.

Industrial Applications

The torque window of the AUMA SQ 05.2 suits the smaller valves that populate utility rooms and skid-mounted packages: ball valves on chemical dosing lines, small butterfly valves on chilled-water branches, and dampers on ventilation and air-handling units. District cooling plants, hospital complexes and hospitality chains in Muscat commonly have large numbers of such valves, and automating them with a compact actuator reduces walk-rounds and enables remote scheduling from the building management system. The very fast 4 s option also serves process applications where a valve must close promptly on a trip signal.

In Oman and the GCC, Seven Star LLC supplies the SQ 05.2 to EPC contractors, municipal utilities and industrial end users, including projects in the Sohar and Salalah economic zones. Buyers who need a larger torque class can step up to the next size.

Neighbouring sizes in the same range include the AUMA SQ 07.2 and AUMA SQ 10.2.

For the family overview, see the AUMA SQ part-turn actuator range, for control options see the AUMA MATIC AM/AC integral actuator controls, and for adjustable operating time see the AUMA SQV variable-speed part-turn actuator.

Technical Specifications

The table summarises the size-specific data AUMA publishes for the AUMA SQ 05.2 with a 3-phase AC motor in open-close duty.

Parameter Specification
Model AUMA SQ 05.2 (3-phase AC, AUMA NORM)
Tripping torque range 50 Nm – 150 Nm
Operating times for 90° 4 – 63 s at 50 Hz (3 – 50 s at 60 Hz)
Number of starts 60 per hour maximum
Valve attachment (EN ISO 5211) F05/F07 standard, F10 option
Valve shaft, max. 25.4 mm cylindrical, 22 mm square, 22 mm two-flat
Handwheel Ø 160 mm, 11 or 16 turns for 90°
Weight, approx. 21 kg (27 kg with base and lever)
Swing angle 75° to below 105° (standard)
Type of duty Short-time duty S2 – 15 min, classes A and B (EN ISO 22153)
Motor protection Thermoswitches (standard), PTC thermistors (option)
Enclosure protection IP68
Corrosion protection KS (KX option)
Ambient temperature -30 °C to +70 °C (standard)

Ordering details for SQ 05.2

The SQ 05.2 technical data lists the valve mounting arrangement as F05 / F07 (EN ISO 5211); option F10. Confirm the required 90-degree travel time at the site supply frequency and the coupling bore on the valve shaft.

Technical reference

Request a Quote for AUMA SQ 05.2

Seven Star LLC invites buyers across Oman and the GCC to submit a formal RFQ for the AUMA SQ 05.2. Send us the valve make, the torque at the seat, the supply voltage and the control philosophy, and our instrumentation division will confirm the flange, coupling bore and operating time. Current availability, the technical data sheet linked on this page and commissioning guidance are available on request, and as a supplier of AUMA products in Oman and the GCC we confirm lead time for every drive at quotation. Ask for the AUMA SQ 05.2 data sheet and a formal AUMA SQ 05.2 quotation today.

Datasheets & Documents
  • PDF Datasheet AUMA SQ 05.2 - SQ 14.2 Technical Data (3-phase AC, open-close duty) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SQ 05.2 Part-Turn Electric Actuator

Answers from our engineering team on installation, compatibility and integration.

01What torque range does the AUMA SQ 05.2 cover?
The AUMA SQ 05.2 has an adjustable tripping torque of 50 Nm to 150 Nm for the OPEN and CLOSE directions. This is the lowest torque class in the SQ .2 range and is intended for small ball, plug and butterfly valves.
02Which valve flanges fit the AUMA SQ 05.2?
The standard attachment is EN ISO 5211 F05/F07, with F10 as an option. The coupling accepts shafts up to 25.4 mm cylindrical, 22 mm square or 22 mm two-flat.
03How fast can the AUMA SQ 05.2 operate a valve?
AUMA lists operating times of 4 s up to 63 s for a 90 degree stroke at 50 Hz, selected when the order is placed. Slower times protect long pipelines from pressure surges.
04Is there a DC or single-phase version of the AUMA SQ 05.2?
AUMA publishes separate technical data for 1-phase AC and for DC motor versions of this size, with their own weights and operating times. Confirm the supply and the required version when requesting a quotation.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every actuator is genuine AUMA product supplied with correct documentation and local technical support.