- Automation & ControlView all 3,072 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AUMA
AUMA AC 01.2-SIL Functional Safety Actuator Controls
Description
Overview
The AUMA AC 01.2-SIL is the functional-safety version of the AUMATIC actuator controls, offered as AC 01.2-SIL for non-hazardous areas and as ACExC 01.2-SIL for explosion-proof duty. It adds a dedicated SIL module to the standard AC 01.2 platform so that SA .2 multi-turn and SQ .2 part-turn actuators can be used in safety-related systems. When a safety function is requested, the standard logic is bypassed and the safe SIL module executes the demand, which means the safety function always overrules normal operation.
In Oman and the GCC, Seven Star LLC proudly supplies the AUMA AC 01.2-SIL to customers across the Sultanate of Oman and the wider GCC. We work with process safety engineers in Oman and the GCC to align SIL actuator selection with the plant safety requirement specification.
Operating Principle of the AUMA AC 01.2-SIL
In a conventional emergency shutdown loop, a valve actuator must reach its safe position even when the normal control path has failed. The AUMA AC 01.2-SIL achieves this with redundant, low-active 24 V DC inputs that are monitored for wire breaks. Safe ESD can be configured to run to end position CLOSED or end position OPEN. An optional Safe STOP function adds two inputs for STOP in the OPEN and/or CLOSE direction, and Safe ESD and Safe STOP can be combined, in which case ESD has priority. Safety functions are executed independently of the position of the LOCAL – OFF – REMOTE selector switch.
The AUMA AC 01.2-SIL is TUV Nord certified according to IEC 61508 Ed. 2 and is suitable for safe OPENING/CLOSING (ESD) up to SIL 2 in single-channel systems and up to SIL 3 in redundant systems, safe STOP up to SIL 2, and safe end position feedback up to SIL 2 or PL c according to ISO 13849. Continuous self-diagnosis supervises actuator operation, the redundant wiring and the internal SIL components, and any fault generates a SIL collective failure signal through a potential-free change-over contact.
Engineering Design of the AUMA AC 01.2-SIL
The AUMA AC 01.2-SIL retains the full AUMATIC feature set: illuminated graphic display, lockable local controls, Bluetooth commissioning, optional positioner and PID process controller, and fieldbus interfaces including Profibus DP/DP-V2, Profinet, Modbus RTU/TCP, Foundation Fieldbus, HART and WirelessHART. The SIL module is an additional hardware layer; the optional external 24 V supply of the electronics refers only to the standard components, not to the SIL components. Enclosure protection is IP68 with KS corrosion protection, and the ambient temperature range of the standard version is −25 °C to +70 °C, with an extreme low-temperature option down to −60 °C.
Because functional safety restricts the configuration, the actuator must carry a blinker transmitter, is supplied with the motor locked in the disengaged position until the lock is released, and only clockwise-closing versions are permitted. Selectable seating types for safety operation include forced limit seating, forced limit seating with overload protection, forced torque seating, or no seating, so the safety behaviour can be matched to the valve design. Torque monitoring and thermal protection can be bypassed during safe ESD when the process requires the valve to reach its position at any cost.
Key Features
The AUMA AC 01.2-SIL brings certified safety performance to electric valve actuation:
- TUV-certified according to IEC 61508 Ed. 2 for safety instrumented functions on SA .2 and SQ .2 actuators.
- Safe ESD OPEN or CLOSE with redundant low-active inputs, applicable up to SIL 2 single-channel and SIL 3 in a 1oo2 redundant arrangement.
- Optional Safe STOP OPEN and Safe STOP CLOSE, combinable with either ESD function.
- Wire-break-proof 24 V DC safety inputs and continuous monitoring of wiring, actuator operation and internal SIL components.
- Optional safe end position feedback up to SIL 2, or PL c per ISO 13849 under a separate declaration of incorporation.
- Safety functions execute regardless of the LOCAL – OFF – REMOTE selector switch position.
- Explosion-proof ACExC 01.2-SIL variant for hazardous areas with the same safety functions.
- Full AUMATIC diagnostics, data logging and fieldbus options remain available alongside the safety module.
Industrial Applications
Safety instrumented systems protect people, plants and the environment in oil and gas, petrochemical, power and chemical facilities. In Oman, the AUMA AC 01.2-SIL is relevant to emergency shutdown valves on wellhead and pipeline manifolds, boiler and turbine fuel isolation, burner management and high-integrity pressure protection valves, as well as isolation valves on hazardous chemical storage near the industrial zones of Sohar, Duqm and Salalah. Its fieldbus capability allows the same actuator to take part in normal process control and in the safety loop with the standard logic bypassed during an emergency.
In Oman and the GCC, Seven Star LLC supplies the AUMA AC 01.2-SIL and the explosion-proof ACExC 01.2-SIL together with matching SA .2 and SQ .2 actuators, and can support engineering teams who need safety manuals, declarations and configuration advice for SIL verification. Selection of the right SIL architecture always depends on the plant safety requirement specification, which our team will coordinate with AUMA. Related AUMA products worth comparing with the AUMA AC 01.2-SIL include the AUMA MATIC AM/AC integral actuator controls, the AUMA ACExC 01.2 and the AUMA FQM/FQMEx fail-safe unit, which cover neighbouring duty types and sizes.
Technical Specifications
The table summarises key data of the AUMA AC 01.2-SIL and ACExC 01.2-SIL from the AUMA technical data sheets, both of which can be downloaded from this page.
| Parameter | Specification |
|---|---|
| Model | AUMA AC 01.2-SIL; explosion-proof version ACExC 01.2-SIL |
| Suitable actuators | SA .2 and SQ .2 ranges (ACExC 01.2-SIL: SAEx/SAREx .2 and SQEx/SQREx .2) |
| Safety certification | TUV Nord, IEC 61508 Ed. 2 |
| Safety integrity level | Safe ESD and Safe STOP up to SIL 2 (single channel); Safe ESD up to SIL 3 (redundant 1oo2) |
| Safety functions | Safe ESD OPEN/CLOSE; Safe STOP OPEN/CLOSE (option); combination with ESD priority; safe end position feedback (option) |
| Safety inputs | Redundant low-active 24 V DC inputs, approx. 10 mA per input |
| SIL status signal | 1 potential-free change-over contact (max. 24 V DC/1 A) |
| Explosion protection (ACExC) | II2G Ex de IIC T4 or T3; II2D Ex tb IIIC T130 °C or T190 °C Db IP6x |
| Mains voltage | 3-phase 220–690 V AC, ±10 % |
| Ambient temperature | AC 01.2-SIL: −25 °C to +70 °C; extreme low temperature option to −60 °C |
| Enclosure / corrosion protection | IP68 / KS |
Request a Quote for AUMA AC 01.2-SIL
Submit an RFQ for the AUMA AC 01.2-SIL with the actuator size, supply voltage, required SIL level and hazardous-area classification, and Seven Star LLC will coordinate configuration, pricing and lead time. Both technical datasheets are available for download on this page, and our instrumentation division in Muscat can support your engineering and procurement teams. In Oman and the GCC, Seven Star LLC supplies AUMA products on request with local technical support.
Datasheets & Documents
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA AC 01.2-SIL Functional Safety Actuator Controls
Answers from our engineering team on installation, compatibility and integration.
01What SIL level can the AUMA AC 01.2-SIL achieve?
Safe ESD OPEN/CLOSE can be applied up to SIL 2 in a single-channel system and up to SIL 3 in a redundant system, for example a 1oo2 architecture, according to IEC 61508 Ed. 2. Safe STOP and safe end position feedback are applicable up to SIL 2.
02How does the SIL function override normal operation?
When a safety function is requested, the standard AC logic is bypassed and the independent SIL module executes the command. The safety function therefore always overrules standard operation, and it works regardless of the position of the LOCAL - OFF - REMOTE selector switch.
03Is an explosion-proof version available?
Yes. The ACExC 01.2-SIL provides the same safety functions in an explosion-proof housing for combination with SAEx/SAREx .2 and SQEx/SQREx .2 actuators. Its technical data sheet is included for download on this page.
04Are there restrictions on the actuator configuration?
Yes. Because of functional safety requirements, the actuator must be equipped with a blinker transmitter, is delivered with the motor locked in disengaged position until the lock is released, and only clockwise-closing versions may be used.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC and supplies genuine AUMA controls and actuators with local technical support.


















Reviews