Brand: AUMA
AUMA SAREx 10.2 Explosion-Proof Modulating Actuator
Description
Overview
AUMA SAREx 10.2 brings 60 to 120 Nm tripping torque (S4-25 %) and up to 60 / 30 Nm modulating torque (S4-25 % / S4-50 %) to the single F10 flange of EN ISO 5210, as third frame of the modulating Ex range.
The SAREx 10.2 is supplied across Oman and the GCC by Seven Star LLC, a trusted AUMA supplier, with quotation, delivery planning and commissioning support. Plants in Duqm and Salalah are served from Muscat. Compare it with the Ex modulating range (SAREx), the SAEx series overview and the AUMA MATIC AM/AC integral actuator controls.
Operating Principle of the AUMA SAREx 10.2
In the SAREx 10.2, modulating torque is 60 Nm (S4-25 %) and 30 Nm (S4-50 %) up to 45 rpm, and 50 / 25 Nm at 63 to 90 rpm. The reduction gear and a mechanical counter system keep position, and an AMExC or ACExC control sends the pulses. Self-locking is documented for the whole series.
Engineering Design of the SAREx 10.2
The SAREx 10.2 has a 50 ms minimum pulse and reversal pulses of up to 260 ms at the slowest speed, so slower speeds are the usual choice for gentle positioning. Its 26 to 28 kg mass and 200 mm handwheel suit medium control valves. Check that valve friction stays below the 60 Nm modulating torque (50 Nm above 45 rpm) over the whole stroke.
The wiring route is an AUMA Ex plug/socket connector (KT) with spring-clamp control terminals; the housing is IP68 and the heater option is 12.5 W.
Key Features of the AUMA SAREx 10.2
What the AUMA SAREx 10.2 offers at a glance:
- Trip torque from 60 to 120 Nm for S4-25 % duty, up to 90 Nm for S4-50 %.
- Continuous positioning torque of 60 / 30 Nm at S4-25 % / S4-50 %.
- Output speeds of 4–90 rpm at 50 Hz, with starts graded by speed band.
- Approximate weight of 26 kg (4–22 rpm), 28 kg (32–90 rpm) and 200 mm handwheel.
- Pulse timing 50 ms (same direction); on reversal 260 ms at 4 rpm down to 60 ms at 90 rpm. Motors of 0.06–0.70 kW at 400 V.
Selecting the AUMA SAREx 10.2 for Your Valve
The SAREx 10.2 provides 60 to 120 Nm tripping torque and a 60 Nm modulating torque at S4-25% for speeds up to 45 rpm. Its F10 flange and 40 mm stem capacity suit medium-size control valves in hazardous areas. The permissible starts per hour are 1,000 up to 45 rpm and 800 from 63 to 90 rpm, which supports closed-loop control with frequent small corrections.
The SAREx 10.2 doubles the SAREx 07.6 trip ceiling from 60 to 120 Nm on an F10 flange with a 200 mm handwheel. Valves above 120 Nm move to the SAREx 14.2 on F14, rated to 250 Nm.
AUMA SAREx 10.2 Modulating Torque and Starts by Speed
These are the modulating limits of the AUMA SAREx 10.2 by output speed, valid at nominal voltage and +40 °C. Tripping torque is adjustable up to 120 Nm (S4-25 %) or 90 Nm (S4-50 %). Illustrative calculation, not AUMA data: a control valve with 10 turns per stroke needs 75 s at 8 rpm, 13 s at 45 rpm and 7 s at 90 rpm for a full stroke.
| Output speed, rpm | Modulating torque, S4-25 / S4-50 %, Nm | Maximum starts per hour |
|---|---|---|
| 4–45 | 60 / 30 | 1,000 |
| 63–90 | 50 / 25 | 800 |
Loop-tuning note: the SAREx 10.2 allows 1,000 starts per hour up to 45 rpm and 800 from 63 rpm, with a 50 ms minimum pulse and reversal pulses between 260 ms (4 rpm) and 60 ms (90 rpm). Because modulating torque also steps down from 60 Nm to 50 Nm at 63 rpm, speeds up to 45 rpm are the usual choice when valve friction is above 50 Nm.
Worked Sizing Example for the SAREx 10.2 (Illustrative Calculation)
A level control valve in a produced-water separator has a friction torque of 45 Nm. The SAREx 10.2 provides 60 Nm at S4-25 % up to 45 rpm, which suffices, while the 50 Nm limit at 63 to 90 rpm leaves little margin. A speed of 16 to 22 rpm, with 1,000 starts per hour and a reversal pulse of 100 to 90 ms, is typically a good compromise between response and positioning accuracy. This is an illustrative calculation, not AUMA data.
Motor and Electrical Data of the AUMA SAREx 10.2
4 speed points from AUMA’s separate electrical data sheet (S4-25 %, 400 V / 50 Hz), 0.06 to 0.70 kW; approximate values that are not part of the technical datasheet attached here.
| rpm | Motor type | kW | IN, A | Imax, A | IA, A | cos φ |
|---|---|---|---|---|---|---|
| 4 | VDXR071-4-0,06 | 0.06 | 0.5 | 0.6 | 2.0 | 0.40 |
| 22 | VDXR071-2-0,25 | 0.25 | 1.3 | 1.8 | 4.5 | 0.52 |
| 45 | ADXR071-4-0,40 | 0.40 | 2.5 | 3.0 | 8.5 | 0.42 |
| 90 | ADXR071-2-0,70 | 0.70 | 3.0 | 4.5 | 16 | 0.54 |
Explosion Protection and Installation Notes for the AUMA SAREx 10.2
Standard ATEX markings of the SAREx 10.2 per AUMA: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db. Certificate: DEKRA 11ATEX0008 X. Confirm temperature class and zone on the nameplate.
Manual operation by the 200 mm handwheel does not rotate during electrical operation, and options include a lockable handwheel and a power tool with a square 30 mm or 50 mm drive.
Industrial Applications
The AUMA SAREx 10.2 is typically applied to medium-size control valves in refineries, gas plants and fuel terminals where modulating duty is needed in Zone 1 or Zone 2. Typical tasks include flow control in loading lines, level control in separators and pressure regulation in fuel-gas headers.
Seven Star LLC supplies the SAREx 10.2 across Oman, Sohar, Duqm and Salalah, with ATEX documentation and project-specific advice on speed selection and control-loop tuning.
Technical Specifications
The table summarises the AUMA SAREx 10.2; AUMA’s official data sheet is the binding reference.
| Parameter | Specification |
|---|---|
| Model | AUMA SAREx 10.2 |
| Torque range S4-25 % | 60–120 Nm |
| Output speeds | 4–90 rpm |
| Flange / stem | F10 / 40 mm |
| Handwheel / weight | 200 mm / 26 kg (4–22 rpm), 28 kg (32–90 rpm) |
| Gas group | IIC |
| ATEX certificate | DEKRA 11ATEX0008 X |
| Enclosure | IP68 |
| Modulating torque | 60 / 30 Nm |
Neighbouring sizes and counterparts: AUMA SAREx 07.6 explosion-proof modulating actuator, AUMA SAREx 14.2 explosion-proof modulating actuator, AUMA SAEx 10.2 explosion-proof actuator and AUMA SAR 10.2 modulating actuator.
Request a Quote for AUMA SAREx 10.2
Please send valve data and loop requirements to Seven Star LLC for an offer on the AUMA SAREx 10.2. The AUMA datasheet is on this page for download.
See also: AUMA SQ 12.2 Part-Turn Electric Actuator; AUMA SA 16.2 Multi-Turn Actuator; AUMA SA 14.2 Multi-Turn Actuator.
Datasheets & Documents
- Datasheet AUMA SAREx 07.2 - SAREx 16.2 Technical Data Sheet (modulating duty, 3-phase AC) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SAREx 10.2 Explosion-Proof Modulating Actuator
Answers from our engineering team on installation, compatibility and integration.
01What torque and modulating torque does the AUMA SAREx 10.2 offer?
The AUMA SAREx 10.2 has a tripping torque range of 60 to 120 Nm at S4-25 % duty and up to 90 Nm at S4-50 %. The maximum modulating torque is 60 / 30 Nm (S4-25 % / S4-50 %), and on some frames it is reduced at higher output speeds.
02Which flange, stem size and handwheel does the AUMA SAREx 10.2 use?
The AUMA SAREx 10.2 uses an EN ISO 5210 F10 flange (DIN 3210 option G0), accepts rising stems up to 40 mm and has a 200 mm handwheel as stated in the data sheet. Approximate weight is 26 kg (4–22 rpm), 28 kg (32–90 rpm).
03What explosion protection does the AUMA SAREx 10.2 carry?
AUMA documents these standard ATEX markings for the AUMA SAREx 10.2: II 2G Ex db eb IIC T4 or T3 Gb, II 2G Ex h IIC T4 or T3 Gb and II 2D Ex tb IIIC T130 °C or T190 °C Db, with certificate DEKRA 11ATEX0008 X. This covers gas group IIC; confirm temperature class T4 or T3 and the zone on the supplied nameplate and certificate.
04How often can the AUMA SAREx 10.2 start and what pulse times apply?
The data sheet gives the maximum starts per hour by speed band (4–45 rpm: 1,000; 63–90 rpm: 800) and the pulse timing as: 50 ms (same direction); on reversal 260 ms at 4 rpm down to 60 ms at 90 rpm. An AMExC or ACExC control is needed to drive the actuator.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so the AUMA SAREx 10.2 is supplied as genuine AUMA product with documentation and regional technical support.