AUMA SAR-UW Underwater Modulating Multi-Turn Actuator
Description
Overview
AUMA SAR-UW is the modulating-duty member of AUMA’s underwater multi-turn actuator family. Where the open-close AUMA SA-UW simply drives a gate from one end position to the other, the AUMA SAR-UW is engineered to hold a submerged valve at any intermediate position and to follow a control signal continuously, with a torque range of 15 Nm to 4,000 Nm and a modulating torque range of 15 Nm to 1,600 Nm. That makes it the right drive for submerged flow-control and level-control gates that must be positioned, not just opened and closed.
In Oman and the GCC, Seven Star LLC supplies the AUMA SAR-UW to desalination plants, water authorities, marine and port operators and EPC contractors across the Sultanate of Oman and the GCC. Because modulating duty puts far more stress on an actuator than occasional switching, correct sizing is critical, and our Muscat instrumentation team reviews the required modulating torque, starts per hour and head of water with you before any order is placed.
Working Principle of the AUMA SAR-UW
The AUMA SAR-UW uses a 3-phase AC asynchronous motor designed for intermittent duty S4-25 % and S4-50 % (class C according to EN ISO 22153) driving a self-locking gear train. A set-point from the control system is compared with the actual valve position reported by the actuator, and the AC controls issue short motor pulses to correct the deviation. Pulse durations are short and well defined, in the order of 60 to 275 ms depending on size and speed, which is what allows fine positioning of a heavy gate without hunting.
The immersed parts follow the same philosophy as the rest of the UW series: a double-sealed terminal compartment, double-sealed cable glands, inner seals on every cover and a solid stainless steel output shaft protect the motor and gearing, while the magnetic limit and torque transmitter (MWG) senses position and torque without wear-prone mechanical switches. The AC actuator controls sit on a wall bracket outside the water and are connected through a purpose-built cable set, so positioner electronics, fieldbus interfaces and diagnostics remain dry and serviceable.
Engineering Design of the AUMA SAR-UW
The AUMA SAR-UW is available in the sizes SAR 07.2-UW to SAR 16.2-UW as well as SAR 25.1-UW and SAR 30.1-UW, with output speeds of 4 to 90 rpm at 50 Hz. The small and medium frame sizes support up to 1,200 starts per hour (up to 1,500 on selected variants), while the large SAR 25.1-UW and SAR 30.1-UW are rated for up to 300 starts per hour. Valve attachments follow EN ISO 5210, F07 to F30, with DIN 3210 options, and output drive type B1 is standard.
Protection is IP68-C15 for a head of water of 15 m, with IP68-C60 for 60 m as an option. The outer parts are aluminium-free and finished in KX-G with a two-layer powder coating plus wet paint, which AUMA qualifies for freshwater (Im1), seawater (Im2) and seafloor (Im3) applications. Operating temperature is –30 °C to +70 °C, and a handwheel for manual setting is available for the small and medium frame sizes.
Key Features
The following characteristics define the AUMA SAR-UW for submerged modulating service:
- Modulating duty S4-25 % and S4-50 % in class C ensures the actuator is rated for continuous positioning rather than occasional switching.
- A torque range of 15 Nm to 4,000 Nm, with a modulating torque range of 15 Nm to 1,600 Nm, covers a wide spread of gate and valve sizes.
- Short, repeatable pulse durations give fine position resolution for heavy submerged gates.
- Continuous underwater use is certified to IP68-C15 as standard, with a 60 m head-of-water option.
- Double-sealed cable glands and a doubly sealed terminal compartment keep water out of the actuator even at the cable entry.
- The non-intrusive magnetic limit and torque transmitter removes mechanical switches from the underwater housing.
- KX-G corrosion protection with aluminium-free outer parts suits freshwater, seawater and seafloor conditions.
- AC actuator controls on a wall bracket provide positioner, diagnostics and fieldbus integration in a dry location.
Industrial Applications
The AUMA SAR-UW is used where a submerged valve or gate has to regulate rather than isolate: level control gates in water intake channels, flow-regulation gates at the head of cooling-water circuits, adjustable weirs and sluice gates in irrigation and flood-protection structures, and bypass or dosing gates in treatment works. In the Sultanate of Oman this includes seawater intake structures serving the coastal desalination and power plants near Sohar, Barka and Salalah, and the falaj-fed and wadi-management structures that regulate seasonal flow.
In Oman and the GCC, Seven Star LLC supplies the AUMA SAR-UW together with the matching AC controls, cable set and documentation. If a submerged valve only needs to open and close, we will point you to the open-close AUMA SA-UW, which avoids paying for modulating capability you do not need; if the process demands positioning, our team will confirm that the modulating torque and starts-per-hour rating of the chosen SAR-UW size match the control loop. If the AUMA SAR-UW is not the closest fit for a valve, see the AUMA SA-UW, the AUMA SAR 14.1 multi-turn actuator or the AUMA MATIC AM/AC integral actuator controls for alternatives from the same AUMA family.
Technical Specifications
The table collects the main data of the AUMA SAR-UW from the AUMA product page and technical data sheet PR01425 (SAR 07.2-UW to SAR 16.2-UW) and its companion sheet for SAR 25.1-UW and SAR 30.1-UW.
| Parameter | Specification |
|---|---|
| Model | AUMA SAR-UW (SAR 07.2-UW to SAR 16.2-UW, SAR 25.1-UW, SAR 30.1-UW) |
| Type of duty | Modulating duty, S4-25 % and S4-50 %, class C (EN ISO 22153) |
| Torque range | 15 Nm to 4,000 Nm |
| Modulating torque | 15 Nm to 1,600 Nm |
| Output speeds | 4 to 90 rpm at 50 Hz |
| Number of starts | Up to 1,200 per hour (SAR 25.1-UW and 30.1-UW: 300 per hour) |
| Valve attachment | EN ISO 5210 F07 to F30 (DIN 3210 option) |
| Enclosure protection | IP68-C15 (15 m head of water), IP68-C60 (60 m) optional |
| Corrosion protection | KX-G, freshwater Im1, seawater Im2, seafloor Im3 |
| Ambient temperature | –30 °C to +70 °C |
| Controls | AC actuator controls on wall bracket, special cable set required |
Request a Quote for AUMA SAR-UW
To request a quotation for the AUMA SAR-UW, send Seven Star LLC your required modulating torque, positioning accuracy, starts per hour, head of water and cable length. Our instrumentation division will return an RFQ response with the correct size, controls and cable set, and you can download the technical datasheet from this page. In Oman and the GCC, we supply the product with local support, and can advise on lead times and availability.
Datasheets & Documents
- Datasheet AUMA SAR 07.2-UW - SAR 16.2-UW Technical Data Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SAR-UW Underwater Modulating Multi-Turn
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between the AUMA SAR-UW and the AUMA SA-UW?
The SA-UW is designed for open-close duty, while the AUMA SAR-UW is rated for modulating duty S4-25 % and S4-50 % in class C, so it can follow a control signal and hold a submerged valve or gate at intermediate positions.
02What starts per hour can the AUMA SAR-UW handle?
The small and medium frame sizes, SAR 07.2-UW to SAR 16.2-UW, support up to 1,200 starts per hour according to the AUMA product page, while the large SAR 25.1-UW and SAR 30.1-UW are rated for up to 300 starts per hour. Sizing should always be confirmed against the control loop.
03How deep can the AUMA SAR-UW be installed?
Standard enclosure protection is IP68-C15 for a maximum head of water of 15 m. An IP68-C60 version for a head of water of 60 m is available as an option.
04Which materials and coatings protect the AUMA SAR-UW in seawater?
The outer parts are aluminium-free and finished in corrosion class KX-G with a two-layer powder coating and additional wet paint, qualified for freshwater, seawater and seafloor use. The shaft is solid stainless steel.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC is the trusted supplier for AUMA in Oman and the GCC and supplies genuine AUMA actuators with documentation and local engineering support.


















Reviews