Brand:

AUMA SA 14.2 Multi-Turn Actuator

Description

Overview

AUMA SA 14.2 is an AUMA NORM multi-turn actuator for open-close duty with a tripping-torque window of 100 to 250 Nm and 12 output speeds from 4 to 180 rpm. SA 14.2 is the first SA size on the F14 flange. With a tripping-torque window of 100 to 250 Nm it covers the valves that are too stiff for the SA 10.2 but do not yet justify the 200 to 500 Nm SA 14.6, and its 315 mm handwheel gives the operator real leverage for emergency manual operation.

Seven Star LLC supplies AUMA products across Oman and the GCC, and supplies the AUMA SA 14.2 with technical support from Muscat.

Operating Principle

Motor turns are counted by a limit mechanism in the SA 14.2, which stops the stroke at OPEN and CLOSED and trips independently on torque in either direction, adjustable from 100 to 250 Nm. Duty is S2 – 15 min as standard, S2 – 30 min as an option, and the unit is self-locking up to 90 rpm.

Engineering Design of the AUMA SA 14.2

At 180 rpm the S2-15 min torque drops to 200 Nm and the S2-30 min value to 140 Nm, so very short stroking times cost torque. If the valve needs close to 250 Nm, select a speed of 125 rpm or lower, and remember that the actuator is self-locking only up to 90 rpm at 50 Hz.

Key Features

What stands out on the SA 14.2:

  • Mid-range multi-turn actuator for medium gate and globe valves.
  • Torque switches can be set from 100 up to 250 Nm, giving a 2.5:1 adjustment span.
  • At 180 Nm the S2 – 30 min figure sits at 72 percent of the highest tripping torque.
  • Dividing the top torque by the quoted weight gives 5.2 to 5.7 Nm/kg.
  • An illustrative stroke of 30 turns takes about 56.2 seconds at 32 rpm.
  • Smaller loads belong to the SA 10.2; larger ones move up to the SA 14.6.
  • Separate AUMA documents list the dimensions and the electrical data.

Selecting the AUMA SA 14.2

Moving from the SA 10.2 to the SA 14.2 changes several things at once: the flange grows from F10 to F14, the rising-stem capacity from 40 mm to 58 mm, the handwheel from 200 mm to 315 mm, and the weight from about 22 to 25 kg to about 44 to 48 kg. Plan lifting and bracket design accordingly. Within the 100 to 250 Nm window the lower limit matters as much as the upper: valves whose seating torque is only 60 to 80 Nm should stay on the SA 10.2, because the AUMA SA 14.2 cannot be set below 100 Nm.

Typical partners are medium gate valves, large globe valves and stop-check valves, pump-discharge isolation valves, cooling-water and fire-water header valves, and rising-stem sluice gates of moderate size. Wedge-gate valves at higher differential pressure usually land in this torque class once packing friction is added.

Medium gate valves in cooling-water service often look simple but hide two torque peaks: unseating at the start of the opening stroke and wedging at the end of the closing stroke. On the AUMA SA 14.2 the torque switch for each direction is set independently, so the opening switch can be set close to the unseating peak while the closing switch protects the wedge. Where the valve is a wedge gate, ending the closing stroke on torque rather than on the limit switch is normally the right choice, and the limit switch is then set slightly earlier to signal the closed position to the control system.

Sizing example for the AUMA SA 14.2

Take an illustrative wedge-gate valve with a measured breakaway torque of 150 Nm and a running torque of 90 Nm. A 25 percent allowance on the breakaway value gives about 190 Nm, which sits within the 100 to 250 Nm window of the AUMA SA 14.2. A 30-turn stroke at 16 rpm takes about 113 seconds and at 45 rpm about 40 seconds. If the same valve were fitted with the SA 14.6, the minimum tripping torque of 200 Nm would already exceed the 190 Nm target, which is why the smaller frame is the more precise match. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SA 14.2

At 44 to 48 kg the AUMA SA 14.2 is a two-person lift at most, but a lifting eye or hoist is advisable on elevated valve platforms. The F14 flange and 58 mm stem bore accept most medium valve yokes without adapters. The 315 mm handwheel needs swing clearance, so check the distance to pipework and cable trays before fixing the valve orientation, and orient the cable entries downward to stop water running along the cable into the housing.

Industrial Applications

Applications in the Sultanate include seawater cooling circuits at power and desalination plants, pump-station discharge valves on the water-transmission network, process-water headers in refineries and LNG-related utilities, and chilled-water risers in large commercial and hospital developments. In the Salalah free zone and the Duqm industrial area the AUMA SA 14.2 is a common choice for utility isolation valves that must be remotely operated yet remain manually operable during a power cut.

For pump stations and cooling circuits, Seven Star LLC can combine the SA 14.2 with the AUMA SA 10.2 multi-turn electric actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAEx explosion-proof actuator.

Neighbouring sizes and counterparts: AUMA SA 10.2 multi-turn actuator, AUMA SA 14.6 multi-turn actuator, AUMA SAR 14.2 modulating actuator and AUMA SAEx 14.2 explosion-proof actuator.

Technical Specifications

Data of the AUMA SA 14.2 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SA 14.2
Setting range, S2 – 15 min 100 to 250 Nm
Top torque S2 – 30 min 180 Nm
Torque loss at top speeds 200 Nm (S2-15 min) and 140 Nm (S2-30 min) at 180 rpm only
Start limit per hour 60
Available speeds 4 to 180 rpm at 50 Hz, 4.8 to 216 rpm at 60 Hz, 12 steps
Valve interface EN ISO 5210 F14; DIN 3210 G1/2
Largest rising stem 58 mm
Handwheel diameter 315 mm
Approximate weight 44 to 48 kg
Ingress protection IP68
Self-locking range up to 90 rpm (50 Hz) / 108 rpm (60 Hz)

Setpoint guide for the SA 14.2 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
80 100
100 125
120 150
140 175
180 225
200 250

Stroking time for 30 turns at the SA 14.2 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 30 turns at 50 Hz
4 4.8 450
5.6 6.7 321
8 9.6 225
11 13 164
16 19 113
22 26 82
32 38 56
45 54 40
63 75 29
90 108 20
125 150 14
180 216 10

Ordering details for SA 14.2

The SA 14.2 technical data lists the valve mounting arrangement as F14 (ISO 5210), DIN 3210 G1/2. Record output speed at the site supply frequency, valve travel and required seating torque when selecting the drive.

Technical reference

Request a Quote for AUMA SA 14.2

Send Seven Star LLC your valve torque, the F14 interface details and the controls you prefer, and a quotation for the AUMA SA 14.2 follows. The AUMA datasheet is available through the download link on this page.

Datasheets & Documents
  • PDF Datasheet AUMA SA 07.2 - SA 16.2 Technical Data Sheet (covers AUMA SA 14.2) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SA 14.2 Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SA 14.2?
The tripping torque of the AUMA SA 14.2 is adjustable between 100 and 250 Nm in S2 - 15 min duty, and the S2 - 30 min maximum is 180 Nm. Torque is reduced at the highest speeds: 200 Nm (S2-15 min) and 140 Nm (S2-30 min) at 180 rpm only.
02Which output speeds and starts per hour does the AUMA SA 14.2 offer?
The AUMA SA 14.2 offers 12 output speeds from 4 to 180 rpm at 50 Hz and up to 60 starts per hour, and it is self-locking up to 90 rpm (50 Hz) / 108 rpm (60 Hz). An illustrative valve needing 30 turns takes about 56.2 seconds at 32 rpm.
03Which valve flange and stem size does the AUMA SA 14.2 fit?
The AUMA SA 14.2 is attached through an EN ISO 5210 F14 flange, with a DIN 3210 G1/2 flange as an option. The bore accepts a rising stem up to 58 mm in diameter. Other output drive types such as A, B2, B3, B4, C and D are available on request.
04When should I choose the AUMA SA 14.2 instead of a neighbouring size?
The AUMA SA 14.2 suits valves that need roughly 100 to 250 Nm at the actuator. Smaller loads belong on the SA 10.2, and loads between 250 and 500 Nm move to the SA 14.6, which shares the same F14 flange but has a 400 mm handwheel and a higher torque ceiling.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SA 14.2 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.