- Automation & ControlView all 3,095 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Encoders
- Motor Soft Starters
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AUMA
AUMA SQR 05.2 Modulating Part-Turn Actuator
Description
Overview
AUMA SQR 05.2 is the smallest member of the modulating SQR .2 range, designed for valves that sit inside a control loop and are repositioned many times an hour. Its tripping torque can be adjusted between 75 Nm and 150 Nm, but the figure that matters for control duty is the maximum modulating torque of 75 Nm at S4 – 25 %. That distinction between tripping and modulating torque is the first thing to understand when choosing between an SQ 05.2 and an SQR 05.2.
In Oman and the GCC, Seven Star LLC proudly supplies the AUMA SQR 05.2 to process, HVAC and utility customers in Oman and the GCC. We help engineers in Muscat, Sohar and Salalah check the control valve torque, the flange pattern and the positioner interface so the loop performs as designed from the first day.
Modulating Duty at the Small End
A modulating actuator receives a setpoint, moves a short distance, stops and holds, and then repeats the cycle as the process drifts. The AUMA SQR 05.2 is built for this pattern with a rating of up to 1,500 starts per hour, a pulse duration of 50 ms for movement in the same direction, and a minimum pulse on reversal of 160 ms at the fastest 8 s ratio rising to 800 ms at the slowest 63 s ratio. These figures define how finely the actuator can step and how quickly it can reverse direction without overshooting.
Six operating times are offered at 50 Hz: 8, 11, 16, 22, 32 and 63 seconds. The fast ratios give a responsive loop for flow control on compact lines, while the 63 s ratio gives a very gentle stroke for sensitive systems. The S4 – 25 % rating covers a modulating torque of up to 75 Nm, and an S4 – 50 % option, available for all but the 63 s ratio, allows 55 Nm modulating torque, with the maximum tripping torque limited to 110 Nm. Choosing the duty class early avoids thermal overload in service.
Engineering Design of the AUMA SQR 05.2
The housing and mechanical interface of the AUMA SQR 05.2 are those of the SQ .2 family: an F05/F07 flange with F10 option, a splined coupling for shafts up to 25.4 mm cylindrical, 22 mm square or 22 mm two-flat, and a 160 mm handwheel that needs 11 or 16 turns for 90 degrees. This means installation drawings prepared for the open-close SQ 05.2 carry across, which simplifies conversion of an on-off valve to a control valve.
The unit weighs about 21 kg, or 27 kg with base and lever, and roughly 23 kg and 29 kg in the 1-phase AC version. Protection is IP68 with KS corrosion protection as standard. For positioning, the actuator is combined with AM or AC actuator controls, which accept an analogue setpoint or fieldbus telegram and return position and status, and with the electronic magnetic limit and torque transmitter available through the AC controls.
Key Features
The AUMA SQR 05.2 brings control-valve capability to a compact, light housing.
- Rated for modulating duty S4 – 25 % with up to 1,500 starts per hour for closed-loop control.
- A 75 Nm to 150 Nm tripping torque range with a 75 Nm modulating torque suits small control valves.
- A 50 ms pulse duration and reversal pulses from 160 ms support fine positioning steps.
- Six operating times from 8 s to 63 s let the loop speed be matched to the process.
- An S4 – 50 % option raises the duty rating at reduced modulating torque for demanding loops.
- F05/F07 flange with F10 option and shafts up to 25.4 mm cover typical compact valves.
- IP68 and KS protection give reliable service outdoors and in humid plant rooms.
- AM and AC controls add analogue setpoint, fieldbus communication and diagnostics.
Selection Guidance for the AUMA SQR 05.2
Before ordering the AUMA SQR 05.2, separate the two jobs the actuator performs. Seating the valve needs the tripping torque, anywhere from 75 Nm to 150 Nm, while positioning it in service needs only the modulating torque of up to 75 Nm. A valve whose in-service torque is close to 75 Nm is at the limit of this frame and should be moved up to the SQR 07.2, because a modulating drive that regularly works at its rating runs hotter and wears faster.
Next, choose the stroke time from the process, not from habit. A fast 8 s ratio makes a nimble loop but can excite oscillation if the controller is aggressive, whereas 22 s or 32 s is often smoother for flow control. Finally, check the supply: the 1-phase AC version weighs about 2 kg more than the 3-phase unit, and AM or AC controls must be chosen to match.
Industrial Applications
The AUMA SQR 05.2 belongs on small control valves where precise positioning matters but torque demand is modest: temperature control on heat exchangers, flow regulation on chemical dosing skids, and air-flow dampers on large building HVAC systems. District cooling operators in Muscat use this size for branch balancing valves, while compact process skids in industrial zones use it where an SQ would wear out quickly from frequent small moves.
In Oman and the GCC, Seven Star LLC supplies the SQR 05.2 with local support. Where the torque demand is higher, look at the next frame.
Larger modulating options include the AUMA SQR 07.2 and AUMA SQR 10.2.
The open-close equivalent is part of the AUMA SQ part-turn actuator range, variable-speed drives are described under the AUMA SQV variable-speed part-turn actuator, and controls under the AUMA MATIC AM/AC integral actuator controls.
Technical Specifications
The table summarises AUMA’s published data for the AUMA SQR 05.2 with a 3-phase AC motor in modulating duty.
| Parameter | Specification |
|---|---|
| Model | AUMA SQR 05.2 (3-phase AC, AUMA NORM) |
| Tripping torque range | 75 Nm – 150 Nm; S4 – 50 % option up to 110 Nm (not at 63 s) |
| Modulating torque, max. | 75 Nm at S4 – 25 %, 55 Nm at S4 – 50 % |
| Operating times for 90° | 8 – 63 s at 50 Hz (6 – 50 s at 60 Hz) |
| Number of starts | 1,500 per hour maximum |
| Pulse duration on reversal | 160 ms – 800 ms depending on speed |
| Pulse duration, same direction | 50 ms |
| Valve attachment (EN ISO 5211) | F05/F07 standard, F10 option |
| Valve shaft, max. | 25.4 mm cylindrical, 22 mm square, 22 mm two-flat |
| Handwheel | Ø 160 mm, 11 or 16 turns for 90° |
| Weight, approx. | 21 kg (27 kg with base and lever) |
| Type of duty | Intermittent duty S4 – 25 %, class C (S4 – 50 % option) |
| Swing angle | 75° to below 105° (standard) |
| Enclosure protection | IP68 |
| Corrosion protection | KS (KX option) |
| Ambient temperature | -30 °C to +70 °C (standard) |
Request a Quote for AUMA SQR 05.2
Seven Star LLC welcomes RFQs for the AUMA SQR 05.2 from control engineers and procurement teams in Oman and the GCC. Tell us the control valve make, the modulating torque, the supply voltage and the setpoint interface, and we will respond with a formal quotation, stock position and the technical data sheet. In Oman and the GCC, we supply every drive on request, with lead time confirmed at quotation. Request a formal AUMA SQR 05.2 offer today.
See also: AUMA SAEx 07.2 Explosion-Proof Multi-Turn Actuator.
Datasheets & Documents
- Datasheet AUMA SQR 05.2 - SQR 14.2 Technical Data (3-phase AC, modulating duty) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA SQR 05.2 Modulating Part-Turn Actuator
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between tripping torque and modulating torque on the AUMA SQR 05.2?
Tripping torque of 75 Nm to 150 Nm is the setting at which the actuator shuts off for protection. Modulating torque of up to 75 Nm at S4 - 25 % is the maximum load permitted during continuous control duty.
02How many starts per hour does the AUMA SQR 05.2 allow?
AUMA rates the SQR range for up to 1,500 starts per hour at intermittent duty S4 - 25 %, class C, which is far above the 60 starts of the open-close SQ.
03Which operating times can the AUMA SQR 05.2 use?
Six times are listed for 90 degrees at 50 Hz: 8, 11, 16, 22, 32 and 63 seconds. The S4 - 50 % option is not offered with the 63 s ratio.
04Do I need external controls for the AUMA SQR 05.2?
Yes, the AUMA NORM version requires external controls. AUMA offers AM and AC actuator controls that accept analogue or fieldbus setpoints and provide feedback.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, so every actuator is genuine AUMA product supplied with correct documentation and local technical support.


















Reviews
There are no reviews yet.