Brand:

Honeywell XNX-UTAV-NNNNN XNX Universal Transmitter mV

Description

Honeywell XNX-UTAV-NNNNN overview

Honeywell XNX-UTAV-NNNNN is the millivolt version of the XNX Universal Transmitter in the UL and CSA, three-quarter inch NPT, painted aluminium enclosure. The V in the fourth position selects the mV personality, which is the board designed to read catalytic bead and other bridge-type sensors. It is delivered without any sensor, relay option or local HART port, so it is the plain base unit for a flammable gas point detector or for a retrofit of an existing transmitter.

Sensors that the mV personality supports

  • MPD flammable catalytic sensor (0 to 100 percent LEL).
  • MPD flammable infrared sensor, covering hydrocarbons and methane, and the carbon dioxide infrared option.
  • Sensepoint HT, the high temperature flammable sensor, including the 2106B2310 family.
  • Sensepoint PPM sensors.
  • Model 705 HT sensors.

XNX-UTAV-NNNNN specification

Parameter Value
Personality mV (millivolt), board for MPD, Sensepoint HT, Sensepoint PPM and Model 705 HT
Approval and entries UL and CSA, 5 x 3/4 inch NPT
Supply 16 to 32 VDC, 24 VDC nominal
Power 6.5 W maximum for catalytic or IR sensors
Weight Approx. 2.8 kg (aluminium)
Cable length 347 m on 1.0 mm squared, 551 m on 1.5, 880 m on 2.0, 1408 m on 2.5 mm squared, typical for an mV unit with MPD catalytic sensor
Housing Marine-finish painted aluminium alloy or 316 stainless steel, flameproof
Dimensions 160 x 197 x 114 mm
Entries 5 entries: 2 right, 2 left, 1 bottom
Ingress protection IP66, NEMA 4X
Operating temperature -40 to +65 degrees C
Humidity 0 to 99 percent RH, non-condensing
Output Isolated 4 to 20 mA with HART 6.0, sink, source or isolated
Accuracy of 4-20 mA +/-1 percent of full scale
Safety IEC 61508 SIL 2 assessment

XNX-UTAV-NNNNN versus XNX-AMSV-NNCB1

The XNX-AMSV-NNCB1 has ATEX and IECEx approval, M25 entries, 316 stainless steel, and a catalytic bead MPD sensor included, whereas the XNX-UTAV-NNNNN has UL and CSA approval, NPT entries, aluminium, and no sensor. The electronics are the same mV board and the outputs are the same. The XNX-UTAV-NNNNN is the right base for North American certified installations where the sensor is selected separately.

Typical use of XNX-UTAV-NNNNN

For Class I Division 1 and Zone 1 areas, in which UL lists Groups A, B, C and D and a Zone 1 rating for IIB plus hydrogen, the unit is used with remote high temperature flammable sensors in gas turbine enclosures, with MPD sensors on process skids, and with Sensepoint heads that already exist in older systems. Using one transmitter for all these sensors is what Honeywell calls a common platform, with reduced training and spares.

A particular benefit of choosing the XNX-UTAV-NNNNN as a base unit is its future-proofing. Honeywell describes the transmitter as able to take other output modules as new industry standards appear, and the plug-in POD module that holds the personality board, option board and display can be changed without rewiring the field terminals, because the terminal blocks are cage-style pluggable connectors with retaining screws. A technician can therefore upgrade from the base NNNNN configuration to relays, Modbus or Foundation Fieldbus in the field.

Installation and commissioning

Mount the XNX-UTAV-NNNNN through two integral lugs or on a pipe with the pipe mount kit 1226A0358, or on a ceiling with kit 1226A0355. Sensor connections are made at terminals 1-7 to 1-9, labelled Sense, 0V and Ref, and the power and 4 to 20 mA connections at 1-1 to 1-6. The transmitter accepts a local IS HART port, relay, Modbus or Foundation Fieldbus module in the field, installed by a qualified service engineer.

Because the mV board serves several families of sensors, the user selects the connected sensor type during set-up and the transmitter then applies the matching range and calibration routine. The MPD cartridges are replaced without removing the housing from service, while the Sensepoint HT and PPM heads and the Model 705 HT sensor connect through their own cable and junction box. For remote high temperature sensors Honeywell shows the XNX with a certified UL high temperature junction box, a certified high temperature cable gland and a cable that is not supplied with the transmitter, and with three-quarter inch NPT entries fitted with certified blanking plugs for unused ways.

Plan the cable run to remote bridge sensors carefully. A mV bridge draws a steady supply current and the reference line must not be shared with other signals, and the datasheet’s cable table of 347 metres on 1.0 mm squared, 551 metres on 1.5, 880 metres on 2.0 and 1408 metres on 2.5 mm squared is an upper bound for a typical single transmitter powered from a supply. Refer to the manual for other cable topologies.

Maintenance

Operation is by the magnetic switches on the front, with outputs inhibited while settings change. The display is a large backlit multilingual LCD with text, digits, a bar graph and icons, and status LEDs.

A closing point for specifiers: the XNX-UTAV-NNNNN is the cheapest way into the XNX family in UL and CSA form, because it leaves out the optional relay, Modbus, Foundation Fieldbus and local HART modules and the sensor, but it can be upgraded later. Typical certification for this variant covers Class I Division 1 Groups A, B, C and D, Class II Division 1 Groups F and G, Class I Zone 1 Groups IIB plus hydrogen and Class II Zone 20 and 21 under UL, with CSA approval for Class I Division 1 Groups B, C and D listed separately. The mV XNX-UTAV-NNNNN also appears in Honeywell’s performance listings for UL 913, UL 1203 and CSA C22.2 No. 152.

Documents and quotation

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can send the XNX datasheet with the quotation. Please send an RFQ naming XNX-UTAV-NNNNN, the quantity, and the sensors you plan to connect.

Other Models in the Xnx Range

Seven Star LLC supplies models from the Xnx range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell XNX-UTAI-NNNNN XNX Universal Transmitter IRFire & Gas DetectorsView details
Honeywell XNX-UTAV-NNNNN XNX Universal Transmitter mVFire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet XNX Universal Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell XNX-UTAV-NNNNN XNX Universal Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does the V in XNX-UTAV-NNNNN mean?
V selects the mV (millivolt) personality, which reads catalytic bead sensors such as the MPD, Sensepoint HT, Sensepoint PPM and Model 705 HT.
02Is a sensor included with XNX-UTAV-NNNNN?
No. NNN in the final field means no sensor, so the sensor, for example an MPD or a Sensepoint HT head, is ordered separately.
03How is XNX-UTAV-NNNNN different from XNX-UTAI-NNNNN?
The V version uses the mV board and a 16 to 32 VDC supply, while the I version uses the infrared board for Searchline Excel and Searchpoint Optima Plus with 18 to 32 VDC.
04What approvals does XNX-UTAV-NNNNN have?
UL and CSA, with three-quarter inch NPT entries. The ATEX and IECEx version uses the letters A and M instead.
05What is the maximum power consumption of the mV XNX?
The datasheet gives 6.5 W for an XNX mV unit with a catalytic or infrared cell.