Honeywell SPXCDALMHX Sensepoint XCD H2S Detector LM25
Description
Honeywell SPXCDALMHX is a complete Sensepoint XCD hydrogen sulphide detector: transmitter, plug-in sensor, tri-colour display and relays in one ATEX and IECEx certified aluminium housing. The part number is a code: SPXCD is the product, A is ATEX and IECEx certification, LM is the LM25 aluminium enclosure with M20 entries, and HX is the hydrogen sulphide sensor with a user-adjustable range. Engineers who need a stand-alone H2S point detector with local indication and relay outputs, rather than a bare sensor head, specify this part.
What SPXCDALMHX includes
According to the Honeywell supply description, an XCD detector is delivered with an integral wall mounting plate, two M20 cable entries, one M20 blanking plug, an Allen key for the locking screw, a weatherproof cap, an operating magnet, the sensor cartridge with its retainer, a quick start guide and an instruction manual CD. Default settings, ranges and calibrations are tested at the factory and each unit ships with a calibration and test certificate. The electrochemical H2S cartridge is a plug-in part made in 316 stainless steel, so on site the sensor can be replaced without hot work.
SPXCDALMHX technical specifications
| Parameter | Value |
|---|---|
| Gas | Hydrogen sulphide, electrochemical |
| Default range | 0 to 50.0 ppm |
| User-selectable full scale | 10.0 to 100.0 ppm, 1 ppm steps |
| Default calibration point | 25 ppm |
| Response T90 | Less than 50 s |
| Accuracy | Better than +/-1 ppm |
| Operating temperature | -20 to +55 degrees C (extended -40 to +65 degrees C with reduced accuracy) |
| Default alarms | A1 10 ppm rising, A2 20 ppm rising |
| Housing | Epoxy-painted aluminium alloy LM25, approx. 2.0 kg |
| Power | Up to 3.7 W for electrochemical cells |
| Certification | ATEX II 2 GD Ex d IIC Gb T6 (Ta -40 to +65 degrees C), T5 (Ta -40 to +75 degrees C), Ex tb IIIC T85 degrees C Db IP66 |
| Output | 3-wire 4 to 20 mA, sink or source selectable, plus optional Modbus RTU RS485 (add M to the part number) |
| Relays | 3 x 5 A at 250 VAC, two alarm and one fault, programmable |
| Supply | 16 to 32 VDC for ATEX and IECEx versions |
| Entries | 2 x M20 cable entries |
| Mounting | Integral plate, 4 holes for M8 bolts; optional bracket for 1.5 to 3 inch pipe |
| Ingress protection | IP66 |
SPXCDALMHX versus other XCD H2S options
Aluminium LM25 is the lighter option at about 2.0 kg, while the stainless steel twin, SPXCDASMHX, weighs about 5.0 kg and suits corrosive offshore or coastal atmospheres. If a Modbus RTU port is required the order code becomes SPXCDALMHXM. For North American installations the letters change, giving a UL or c-UL version with three-quarter inch NPT entries and a different certification. Gas versions in the same family include SPXCDALMCX for carbon monoxide, SPXCDALMG1 for hydrogen and SPXCDALMNX for nitrogen dioxide.
Using SPXCDALMHX in sour gas and wastewater areas
Point H2S monitoring with the SPXCDALMHX is common practice around sour crude handling, gas sweetening, flare headers, produced water tanks, sulphur handling, sewer pumping stations and tannery or paper-mill effluent. The SPXCDALMHX hydrogen sulphide unit suits indoor or outdoor use thanks to IP66 protection and a weatherproof cap, and the default alarms of 10 ppm and 20 ppm are set at levels typical of low and high personnel alarms, adjustable at the display.
Installation of SPXCDALMHX
The detector can be fixed to a surface through four mounting holes or clamped to a horizontal or vertical pipe 40 to 80 mm across using the optional bracket SPXCDMTBR. The 15 terminals are plug-and-socket type and accept 0.5 to 2.5 mm squared conductors. For a 24 VDC supply with an electrochemical sensor, Honeywell lists maximum cable lengths from 478 metres on 0.5 mm squared up to 2197 metres on 2.5 mm squared. On the SPXCDALMHX a sink or source switch on the rear of the display module selects the current-loop topology during commissioning.
Sizing the supply matters for this detector. The datasheet states a maximum inrush current of 800 mA at 24 VDC, and a power draw of up to 3.7 W for electrochemical cells, against 4.9 W for catalytic types. An H2S detector built with an electrochemical cell therefore draws less than a flammable catalytic XCD, and a loop supply sized for a catalytic detector will carry it comfortably. The input range of 16 to 32 VDC for the ATEX and IECEx version leaves room for voltage drop on longer cable runs, which suits spread-out tank farms and effluent plants in the Gulf.
For a plant that already has Sensepoint XCD units, the SPXCDALMHX offers the same operator interface as the other gases: the same magnet positions, the same display layout with digits, bar graph and icons, and the same terminal block. Technicians who are trained on one gas can service the SPXCDALMHX, and likewise those who know the SPXCDALMHX can service another gas. Technicians who are trained on one gas can service the rest, and the spare cartridge list is common across the family, which is the stated reason Honeywell describes the platform as reducing spares. Each H2S cartridge is auto-recognised by the transmitter, so no manual configuration is needed after replacement beyond a normal calibration.
Operation and maintenance
Range, relay logic, alarm set points and the tag number are changed through the LCD with the supplied magnet, without opening the enclosure, and outputs are inhibited during adjustment. The display backlight is steady green in normal operation, flashes yellow for a fault and flashes red for an alarm. Spare plug-in H2S cartridges are ordered as SPXCDXSHXSS. A calibration cup S3KCAL and a collecting cone SPXCDCC are listed accessories, together with a sunshade and deluge protection SPXCDSDP.
Controller and output behaviour
Current output is 4.0 to 20.0 mA for normal measurement, 22.0 mA at maximum over range, below 1.0 mA for a fault and either 2.0 or 4.0 mA while inhibited. The relays default to normally open and de-energised for the two alarms and normally open and energised for the fault. The SPXCDALMHX output is wired into any standard PLC or DCS analogue input with a load of up to 250 ohms.
Documents and quotation
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The XCD datasheet can be attached to your quotation. Please send an RFQ with part number SPXCDALMHX, the quantity, whether Modbus is needed and the delivery location.
Datasheets & Documents
- Datasheet Sensepoint XCD Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell SPXCDALMHX Sensepoint XCD H2S Detector
Answers from our engineering team on installation, compatibility and integration.
01What does the SPXCDALMHX part number mean?
SPXCD is the Sensepoint XCD detector, A is ATEX and IECEx certification, LM is the LM25 aluminium enclosure with M20 entries, and HX is the hydrogen sulphide sensor with adjustable range.
02What is the default range of Honeywell SPXCDALMHX?
The default range is 0 to 50 ppm H2S, and users can set the full scale between 10 and 100 ppm in 1 ppm steps from the transmitter display.
03What alarm levels are preset on SPXCDALMHX?
The datasheet lists default alarms of 10 ppm for A1 and 20 ppm for A2, both rising, and they can be changed with the magnet switches.
04Can SPXCDALMHX be ordered with Modbus?
Yes. Honeywell states that adding the letter M to the end of the part number orders the optional Modbus output, so the code becomes SPXCDALMHXM.
05Which spare cartridge fits the SPXCDALMHX?
The spare plug-in hydrogen sulphide cartridge is listed as SPXCDXSHXSS in the XCD datasheet, a 316 stainless steel sensor for 0 to 50 ppm default range.