- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Honeywell
Honeywell Searchline Excel Plus Open Path Gas Detector
Description
Overview
The Honeywell Searchline Excel Plus is the current-generation medium-range open path flammable gas detector from Honeywell, developed for upstream and downstream oil and gas plants, onshore and offshore. A transmitter and a separate receiver are mounted between 2 and 120 metres apart, and the infrared beam between them watches the whole line for hydrocarbon gas clouds. Honeywell designed the Honeywell Searchline Excel Plus to keep working in poor visibility, stating that it can see through thick fog better than other open path detectors, whether NDIR or laser based, and it adds Bluetooth set-up, a high-visibility LED halo status ring, HART and Modbus outputs and TUV SIL 2 certification to the established Searchline concept.
Seven Star LLC supplies the Honeywell Searchline Excel Plus to operators, EPC contractors and maintenance teams in Oman and the GCC as a trusted supplier, with engineering support in Muscat. We can help size path lengths, select the M25 or 3/4 inch NPT version, and assemble the mounting, alignment and test accessories needed for commissioning.
Measurement Principle
Flammable hydrocarbons absorb infrared radiation at specific wavelengths. In an open path system the transmitter sends a beam of infrared energy across the hazard, and the receiver measures how strongly the beam is attenuated at a gas-absorbing wavelength relative to a non-absorbing reference. Because absorption depends on both the gas concentration and the length of cloud the beam passes through, the reading is an integral value expressed in LEL.m (lower explosive limit multiplied by metres). The Honeywell Searchline Excel Plus measures from 0 to 5 LEL.m, with recommended alarm settings of 1 LEL.m (low) and 3 LEL.m (high), and responds with a T90 of less than 3 seconds.
This line-of-sight approach means a leak is detected wherever it crosses the beam rather than only when it reaches a point sensor, which suits wind-dispersed releases on open plant. The detector responds to a wide range of hydrocarbons, including methane, ethane, propane, butane, pentane, hexane, ethylene and propylene, with FM performance approval on most of these and DNV approval for methane and propane. Optical diagnostics in the Honeywell Searchline Excel Plus continuously evaluate window clarity and alignment accuracy so that loss of signal, beam blockage or drift is reported as a warning or fault on the 4–20 mA loop rather than going unnoticed.
Engineering Design of the Honeywell Searchline Excel Plus
Each Honeywell Searchline Excel Plus unit is a stainless steel cylinder about 103 mm in diameter and 325 mm long, weighing roughly 6 kg, rated IP66/IP67 and Type 4X with tested resistance to salt mist and sulfuric atmospheres. Certification covers cULus Class I Division 1 Groups B, C and D and IECEx Ex db ia IIC T4 Gb for flameproof installation or Ex db eb ia IIC T4 Gb for increased safety wiring, with performance approval to ANSI/FM/IEC/EN 60079-29-4. A sunshade is supplied as standard, and advanced optics in both transmitter and receiver keep monitoring active in heavy fog long after other detector types lose coverage.
Installation of the Honeywell Searchline Excel Plus uses the Fixed Platform Universal Mount, and the system part numbers SLXL-PSMGXX and SLXL-PSNGXX include a small stainless steel mount, bracket and plastic sunshade with either M25 or 3/4 inch NPT entries. An alignment scope simplifies aiming the pair. Day-to-day interaction is non-intrusive: technicians pair an intrinsically safe Android device with the detector over Bluetooth at up to about 20 metres and use the Honeywell Fixed Platform App to configure, check status and review the full log of alarms, events and maintenance actions without opening the enclosure.
Key Features
The Honeywell Searchline Excel Plus offers the following practical advantages on site:
- Path lengths from 2 to 120 metres let one detector pair replace many point detectors along process boundaries and fence lines.
- The 0 to 5 LEL.m range and T90 under 3 seconds provide fast warning of hydrocarbon releases.
- Honeywell rates its fog penetration ahead of other NDIR and laser open path detectors, maintaining coverage in low visibility.
- A high-visibility LED halo ring shows instrument status at a glance from ground level.
- Outputs include 4–20 mA with HART, fault, Alarm 1 and Alarm 2 relays rated 2 A, and Modbus.
- Bluetooth connectivity with the Honeywell Fixed Platform App enables set-up and maintenance without opening the housing.
- Window clarity and alignment diagnostics, plus automatic event logging, support maximum uptime.
- The detector is calibration free and is certified SIL 2 by TUV SUD to EN 61508.
Industrial Applications
Open path detection is used wherever a gas cloud could drift across a large or irregular area: around compressor houses and separators, along pipe racks, at the perimeter of tank farms and LPG spheres, across jetties and loading bays, and around offshore modules. In Oman the Honeywell Searchline Excel Plus fits gas processing and condensate facilities in the interior, crude and product terminals near Muscat and Duqm, refineries and petrochemical units in Sohar, LNG plants in Sur and gas-fired power and desalination stations, where hot summers, coastal humidity, dust and morning fog all challenge detection systems.
Because the medium-range Honeywell Searchline Excel Plus shares 4–20 mA, HART and Modbus outputs with common fire and gas controllers, it is straightforward to add to existing systems or to new SIL-rated safety designs. Seven Star LLC supplies Honeywell Searchline Excel Plus transmitter and receiver pairs together with large adjustable brackets, stainless steel sunshades, alignment scopes, functional test filters and gassing cells from Muscat, and our engineers can support layout reviews and commissioning planning across Oman and the GCC.
Technical Specifications
The Honeywell Searchline Excel Plus data below is summarised from the Honeywell datasheet; see the technical manual for full details and ppm.m equivalents.
| Parameter | Specification |
|---|---|
| Model | Searchline Excel Plus (SLXL-PSMGXX M25; SLXL-PSNGXX 3/4 inch NPT) |
| Gases | Methane, ethane, propane, butane, pentane, hexane, ethylene, propylene |
| Range | 0–5 LEL.m; recommended alarms low 1 LEL.m, high 3 LEL.m |
| Path length | 2 m to 120 m (6 ft to 393 ft) |
| Speed of response | T90 less than 3 seconds |
| Analogue output | 4–20 mA linearised 0–5 LEL.m; 1 mA fault, 2 mA inhibit, 3 mA warning, 21 mA overrange |
| Other outputs | HART, fault relay, Alarm 1 and Alarm 2 relays (max 32 V, 2 A resistive), Modbus, Bluetooth |
| Power supply | 24 Vdc nominal (18 to 32 Vdc) |
| Power consumption | Transmitter 3.8 to 11.8 W; receiver 3.0 to 7.4 W (temperature dependent) |
| Operating temperature | –55°C to +75°C |
| Humidity | 0–99% RH non-condensing |
| Repeatability | ±0.4 LEL.m |
| Warm-up time | Less than 5 minutes operational; less than 1 hour fully stabilised |
| Weight | Receiver 6.1 kg; transmitter 6.0 kg |
| Dimensions | 103 mm dia × 325 mm × 180 mm |
| Ingress protection | IP66/IP67, Type 4X |
| Hazardous area | cULus Class I Div. 1 Groups B, C, D T4; IECEx ULD 18.0016X Ex db ia IIC T4 Gb / Ex db eb ia IIC T4 Gb |
| Performance and safety | ANSI/FM/IEC/EN 60079-29-4; SIL 2 (TUV SUD, EN 61508); ATEX, INMETRO, CCCF |
Related Fire and Gas Detection
For the earlier generation open path detector, see the Honeywell Searchline Excel open path detector; for alternative technologies compare the General Monitors IR5500 open path detector and the Honeywell XNX universal transmitter.
To pair gas detection with flame detection, see the Honeywell FS24X Plus flame detector.
How to Order
To request a formal quotation for the Honeywell Searchline Excel Plus, check current availability and lead time or download the technical datasheet, contact the instrumentation division at Seven Star LLC. Send us your path lengths, entry thread, target gas and accessory list, and our engineers in Muscat will confirm Honeywell Searchline Excel Plus availability, lead time and commissioning support for your site in Oman or the GCC.
Datasheets & Documents
- Datasheet Honeywell Searchline Excel Plus Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell Searchline Excel Plus Open Path Gas
Answers from our engineering team on installation, compatibility and integration.
01What path length does the Honeywell Searchline Excel Plus cover?
The Honeywell Searchline Excel Plus is a medium-range open path detector for transmitter to receiver distances from 2 to 120 metres (6 to 393 feet). It measures 0 to 5 LEL.m with a T90 response under 3 seconds.
02How is the Searchline Excel Plus different from the original Searchline Excel?
The Plus model adds Bluetooth set-up through the Honeywell Fixed Platform App, a high-visibility LED halo status ring, HART, Modbus and three relay outputs, window clarity and alignment diagnostics, a universal mount with alignment scope and TUV SIL 2 certification.
03Which gases can the Searchline Excel Plus detect?
It responds to a wide range of hydrocarbons including methane, ethane, propane, butane, pentane, hexane, ethylene and propylene. Most of these carry FM performance approval, and methane and propane are DNV approved.
04Does the Searchline Excel Plus need routine calibration?
Honeywell describes it as low maintenance and calibration free. Functional test filters and a gassing test cell are available as accessories for periodic verification, and the detector logs alarms, events and maintenance actions automatically.
05Can Seven Star LLC supply the Searchline Excel Plus and accessories in Oman?
Seven Star LLC supplies the Honeywell Searchline Excel Plus with brackets, sunshades, alignment scopes and test accessories as a trusted supplier, with engineering support in Muscat for sites across Oman and the GCC.


















Reviews
There are no reviews yet.