Brand:

Honeywell SR-X2V Replacement Oxygen Sensor

Description

Overview

Honeywell SR-X2V is a genuine BW Technologies by Honeywell replacement oxygen (O2) sensor engineered for the GasAlert family of portable multi-gas monitors. Covering a 0–30% volume oxygen measurement range, the Honeywell SR-X2V is factory calibrated and designed for rapid field replacement, restoring full oxygen deficiency and enrichment detection capability to GasAlert MaxXT II, MicroClip XL, Quattro and Micro 5 monitors used extensively across confined space entry and personnel safety programs.

Backed by manufacturer datasheet documentation, Seven Star LLC proudly supplies genuine Honeywell SR-X2V replacement oxygen sensors to industrial plants throughout Oman and the GCC. Every sensor shipped from our Muscat-based facility is sourced directly through Honeywell’s trusted supply channel, ensuring authentic electrochemical cell construction and full compatibility with existing GasAlert monitors already deployed across regional oil and gas, petrochemical and confined space entry safety programs.

Operating Principle

The Honeywell SR-X2V uses an electrochemical sensing cell that generates a current proportional to the partial pressure of oxygen diffusing through a gas-permeable membrane into the sensor housing. As ambient oxygen reacts at the working electrode within the cell, the resulting electrical current is processed by the host GasAlert monitor’s internal circuitry and displayed as a real-time percentage of oxygen by volume, triggering audible and visual alarms if the reading drops below or rises above pre-configured safety thresholds.

Because the electrochemical cell is a consumable component with a finite service life determined by internal electrolyte depletion, periodic sensor replacement is required to maintain measurement accuracy and alarm reliability. The SR-X2V is designed as a direct drop-in replacement for the SR-X10-C1 and SR-X10 legacy sensors, allowing safety teams to restore full monitor functionality quickly without recalibrating the entire instrument from scratch, minimizing the time personnel safety equipment spends out of service.

Engineering Design of the Honeywell SR-X2V

The sensor is housed in a compact cylindrical cartridge with gold-plated connection pins that mate directly into the corresponding slot inside the GasAlert monitor chassis, ensuring reliable electrical contact and correct polarity during installation. A printed caution label instructs technicians not to remove the protective covering prior to installation, preserving the electrochemical cell’s calibrated state until it is placed into active service inside the host instrument.

Physical dimensions and pin spacing are standardized across the GasAlert MaxXT II, MicroClip XT, MicroClip XL, Quattro and Micro 5 platforms, allowing a single sensor part number to service multiple monitor models across a facility’s safety equipment fleet. The sensor carries a two-year warranty from date of manufacture, giving safety managers a predictable replacement interval to budget for as part of routine gas detection equipment maintenance programs.

Key Features

The Honeywell SR-X2V replacement oxygen sensor delivers dependable performance around the following capabilities:

  • Factory-calibrated electrochemical cell covers the full 0–30% volume oxygen measurement range.
  • Direct drop-in replacement for legacy SR-X10-C1 and SR-X10 sensors simplifies fleet-wide upgrades.
  • Compatible across GasAlert MaxXT II, MicroClip XT, MicroClip XL, Quattro and Micro 5 monitor platforms.
  • Gold-plated connection pins ensure reliable electrical contact and correct polarity during installation.
  • Quick cartridge-style replacement minimizes downtime for personnel gas detection equipment.
  • Two-year manufacturer warranty supports predictable maintenance budgeting and replacement scheduling.
  • Genuine BW Technologies by Honeywell construction ensures accurate, reliable oxygen deficiency alarming.
  • Compact, standardized cartridge design supports single-part-number fleet servicing across monitor models.

Industrial Applications

The Honeywell SR-X2V is deployed across confined space entry programs, tank and vessel inspection, and general personnel gas detection duties in oil and gas, petrochemical and utility facilities where oxygen deficiency or enrichment presents a life-safety hazard. In Oman’s upstream and downstream oil and gas operations, as well as refineries, ports and industrial zones across Muscat, Sohar and Salalah, GasAlert monitors fitted with genuine SR-X2V sensors form a core part of confined space entry permit systems and personal protective equipment programs.

Working closely with plant engineers in the region, Seven Star LLC supplies SR-X2V oxygen sensors on request to HSE departments, safety equipment service providers and industrial contractors throughout the region, with lead time confirmed at quotation. Facilities across Sohar’s industrial port zone and Salalah’s free trade zone depend on Seven Star LLC for genuine BW Technologies by Honeywell sensors with confirmed calibration data and traceable sourcing.

Technical Specifications

Parameter Specification
Model Honeywell SR-X2V
Type Electrochemical oxygen (O2) replacement sensor
Measurement Range 0–30% volume oxygen
Compatible Monitors GasAlert MaxXT II, MicroClip XT/XL, Quattro, Micro 5
Replaces SR-X10-C1, SR-X10 sensors
Connection Gold-plated pin cartridge
Warranty 2 years
Weight Approx. 0.5 lbs

Sensor Chemistry and Cell Identification

The cell supplied under the Honeywell SR-X2V part number is a 4OXV CiTiceL oxygen cell configured for a 0–30% volume span. CiTiceL is Honeywell’s own electrochemical cell line, originally developed by City Technology, so the replacement sensor and the host GasAlert instrument come from the same engineering family rather than from an aftermarket supplier reverse-engineering the pin-out. That matters in practice because a non-genuine oxygen cell can present the correct mechanical footprint while delivering a different output current per percentage of oxygen, which the monitor will accept during calibration and then track inaccurately as the cell ages.

Calibration, Bump Testing and Service Life

After fitting a new Honeywell SR-X2V, the monitor should be left to stabilise before a fresh-air calibration is performed at 20.9% oxygen by volume, and Honeywell BW recommends a functional bump test before each day’s use to confirm that both the sensor and the alarms respond. Fleets running a significant number of GasAlert instruments can automate that routine with Honeywell BW docking systems such as MicroDock II, which perform the bump test, record the result, and flag any instrument that fails. Galvanic oxygen cells of this class are consumed by their own reaction chemistry and are additionally shortened by sustained high ambient temperature and very low humidity, so facilities operating in Oman’s summer conditions should plan replacement intervals conservatively and store spare sensors in a cool, sealed condition with the protective covering left intact until installation.

Request a Quote for Honeywell SR-X2V Replacement Oxygen Sensor

Seven Star LLC invites HSE managers and procurement teams across Oman and the GCC to submit a formal RFQ for the Honeywell SR-X2V replacement oxygen sensor. With fast quotation turnaround and technical support, we supply on request with lead time confirmed at quotation, provide technical datasheets on request, and offer direct access to our gas detection instrumentation division for fleet compatibility support.

Related Products

Datasheets & Documents
  • PDF Datasheet Honeywell SR-X2V Replacement Oxygen Sensor Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell SR-X2V Replacement Oxygen Sensor

Answers from our engineering team on installation, compatibility and integration.

01Which GasAlert monitors use the Honeywell SR-X2V sensor?
It fits GasAlert MaxXT II, MicroClip XT, MicroClip XL, Quattro and Micro 5 multi-gas monitors, covering the majority of BW Technologies by Honeywell portable gas detection fleets.
02How long does replacement take?
The cartridge-style SR-X2V installs directly into the monitor slot within minutes, restoring oxygen detection capability quickly without requiring a full instrument recalibration cycle.
03What is the measurement range and accuracy?
The SR-X2V is factory calibrated for a 0-30% volume oxygen measurement range, suitable for both deficiency and enrichment alarming in confined space entry applications.
04Can it replace older SR-X10 sensors?
Yes, the SR-X2V is a direct drop-in replacement for both the SR-X10-C1 and SR-X10 legacy sensors, so existing monitor fleets can be upgraded without hardware changes.
05Is Seven Star LLC an experienced supply partner for Honeywell products?
Yes, Seven Star LLC is an experienced supplier of Honeywell gas detection instrumentation in Oman and the GCC, supplying genuine sensors with full traceability.