Brand: Honeywell
Honeywell MultiRAE Lite Pumped Multi-Gas Monitor PGM-6208
Description
Honeywell PGM-6208 pumped wireless multi-gas monitor overview
The Honeywell MultiRAE Lite is a one-to-six gas monitor for personal protection and leak detection. The pumped model, ordered as Honeywell PGM-6208, has a built-in sampling pump and can use the PID sensor for volatile organic compounds. The manufacturer says the MultiRAE Lite offers the broadest sensor selection in its class and can be configured to meet the compliance needs of different countries and industries.
The monitor has a large graphical display, replaceable sensors, pump and battery, and continuous datalogging. An optional wireless module provides real-time readings and a Man Down alarm to a remote safety officer.
This page summarises the manufacturer documentation for the Honeywell PGM-6208 for buyers in Oman and the GCC. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Key features of the PGM-6208
The following points come from the manufacturer datasheet for the MultiRAE Lite pumped model.
- Over 25 interchangeable, field-replaceable sensors, including PID for VOCs, electrochemical sensors, catalytic and NDIR combustible sensors and NDIR carbon dioxide.
- Five-way local and remote alarm notification: 95 dB audible, vibration, flashing LEDs, on-screen indication and wireless notification.
- Man Down alarm with pre-alarm and real-time remote notification when the wireless option is fitted.
- Intelligent sensors that store calibration data so they can be swapped in the field.
- Continuous datalogging, six months for five sensors at one-minute intervals, with user-set intervals from 1 to 3,600 seconds.
- Large monochrome graphical LCD (128 x 160) with backlight and automatic screen flip.
- Fully automatic bump testing and calibration with the AutoRAE 2 system.
- Certified to CSA Class I Division 1 and ATEX and IECEx Ex ia IIC T4 Ga.
PGM-6208 technical specifications
The table lists the main data for the MultiRAE Lite pumped model from the manufacturer datasheet. Specifications are subject to change by the manufacturer, so confirm the configuration with your quotation.
| Parameter | Value |
|---|---|
| Model | PGM-6208 |
| Version | Pumped |
| Size | 193 x 96.5 x 66 mm |
| Weight | 880 g |
| Battery runtime | about 12 hours (rechargeable Li-ion) |
| Ingress protection | IP-65 |
| Display | Monochrome graphical LCD 128 x 160, backlit |
| Alarms | 95 dB audible, vibration, red LEDs, on-screen, wireless |
| Datalogging | Six months for five sensors at one-minute intervals |
| Operating temperature | -20 to 50 degC |
| Humidity | 0 to 95 percent RH non-condensing |
| Wireless range | About 100 m to RAELink3, about 200 m to EchoView Host or RAEPoint |
| Photoionization (VOC, 10.6 eV) | 0 to 1,000 ppm (pumped only) |
| Catalytic LEL | 0 to 100 percent LEL |
| NDIR methane | 0 to 100 percent LEL or 0 to 100 percent vol. |
| Carbon dioxide (NDIR) | 0 to 50,000 ppm |
| Carbon monoxide (CO) | 0 to 500 ppm |
| Hydrogen sulfide (H2S) | 0 to 100 ppm |
| Oxygen (O2) | 0 to 30 percent vol. |
| Ammonia (NH3) | 0 to 100 ppm |
| Certifications | CSA Class I Div 1; ATEX II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga |
Typical applications in Oman and the GCC
Portable and transportable gas detectors protect people and plant wherever toxic, combustible or oxygen-deficient atmospheres can occur. Typical uses for the MultiRAE Lite pumped model in Oman and the GCC include the following.
- Oil and gas: downstream confined space entry, tank and vessel inspection and leak detection.
- Utilities and power: gas checks in cable tunnels, boiler rooms and pits.
- Water and wastewater: multi-gas monitoring of H2S, CO, oxygen and LEL in sewers and treatment plants.
- Manufacturing: chemical, food, pharmaceutical and telecommunications sites needing four to six gas monitoring.
Selection and compatibility notes for the PGM-6208
The Pumped covers up to six gases, so it suits crews entering confined spaces or surveying leaks. Select the pumped model when sampling at a distance with a hose is needed, when a PID sensor is required, or when automatic calibration on AutoRAE 2 is wanted.
A two-gas combination sensor is required for a six-gas configuration. NDIR combustible sensors need a pumped configuration in CSA countries. Wireless and non-wireless versions are offered, and extra equipment or licences may be needed for remote monitoring. Quote the exact sensor set required.
Installation and commissioning of the PGM-6208
Prepare the MultiRAE Lite pumped model for service as described in the manufacturer user guide.
- Fit the required sensors; calibrate them on installation as the manufacturer recommends.
- Charge the battery before first use and set alarm limits to your site procedure.
- Bump test before each shift or at the interval in your safety plan.
- Configure wireless settings only if remote monitoring is used.
Maintenance and service life
The sensors, pump (pumped model) and battery are replaceable, so service is quick. Keep inlet filters clean, bump test regularly and calibrate at the interval your site safety procedure sets. Replace sensors when they reach end of life.
Related products and ordering notes
Related Honeywell gas detectors available on request include the ToxiRAE Pro and AutoRAE 2. Please specify the sensors, wireless option and accessories required.
PGM-6208 questions in brief
Typical questions about the MultiRAE Lite pumped model concern sensors, alarms and certification. The answers below summarise the main points from the datasheet.
Documents and quotation
The manufacturer datasheet for the PGM-6208 is available from Seven Star LLC with this listing when it is attached, and it should be read together with the installation manual before any engineering decision. To request a quotation, send an RFQ that states the part number PGM-6208, the quantity, the delivery location and, where relevant, the options you need. Seven Star LLC replies with availability and lead time; no price is published on this page.
Ordering Checklist for Honeywell PGM-6208
Before you request a quotation for the Honeywell PGM-6208, confirm the complete order code shown on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If you are upgrading rather than replacing like for like, tell us the existing make and model so the mounting, wiring and connection details can be checked against the fire & gas detectors you already run. For multi-unit orders, list the quantity per site and the required delivery location in Oman or the wider GCC, so packing, documentation and lead time can be confirmed in one quotation instead of several follow-up emails.
Datasheets & Documents
- Datasheet Honeywell MultiRAE Lite Pumped Multi-Gas Monitor PGM-6208 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell MultiRAE Lite Pumped Multi-Gas Monitor
Answers from our engineering team on installation, compatibility and integration.
01How many gases can the PGM-6208 detect?
The MultiRAE Lite monitors one to six gases at once; a two-gas combination sensor is needed for a six-gas configuration.
02What is the difference between the pumped and diffusion MultiRAE Lite?
The pumped model, PGM-6208, has a built-in pump and supports the PID and NDIR sensors; the diffusion model, PGM-6208D, is lighter, rated IP-67 and runs longer on a battery.
03Does the PGM-6208 offer wireless monitoring?
Wireless and non-wireless configurations are available, with Man Down alarm and remote alarm status when the wireless option is fitted.
04What certifications does the PGM-6208 carry?
The datasheet lists CSA Class I Division 1 Groups A to D and ATEX and IECEx Ex ia IIC T4 Ga certification.
05How can I request a quotation for the PGM-6208?
Send an RFQ with the part number, quantity and delivery location. Seven Star LLC will reply with availability and lead time; this page shows no price.