Honeywell 2106B1200 Sensepoint Flammable Sensor 0-100% LEL
Description
Honeywell 2106B1200 catalytic LEL sensor
Honeywell 2106B1200 is the standard Sensepoint flammable gas sensor for 0 to 100 percent of the lower explosive limit, with an M20 thread. Unlike the toxic Sensepoint heads, it is not a loop-powered transmitter: it is a three-wire catalytic bead head that gives a millivolt bridge output to a controller, a bridge-input transmitter or a converter. It is a classic spare for plants that have a large installed base of Honeywell Analytics controllers, and it is one of the heads the XCD RFD transmitter can run on a cable up to 30 metres away.
Datasheet figures for 2106B1200
| Parameter | Value |
|---|---|
| Gas and range | Flammable gas, 0 to 100 percent LEL |
| Thread | M20 |
| Output | Three-wire mV bridge |
| Supply | 200 mA, 0.7 W maximum |
| Operating temperature | -40 to +80 degrees C |
| Warm-up | Less than 10 minutes |
| Response | T50 less than 5 s; T90 less than 10 s |
| Linearity | Less than 5 percent fsd or +/-10 percent of reading |
| Typical life | 5 years; storage over 5 years in original sealed packaging |
| Zero stability | Less than +/-3 percent fsd per year; less than +/-1 percent fsd over temperature; less than +/-1 percent over humidity |
| Span stability | Less than +/-3 percent fsd per year; less than +/-3 percent over temperature; less than +/-2 percent over humidity |
| Weight and body | 190 g, polyphenylene sulphide |
| Protection | IP65; IP67 with weather protection |
Hazardous-area certification of 2106B1200
The flammable head carries three temperature classes: II 2 GD Ex d IIC Gb T85 degrees C for ambient -40 to +55 degrees C, T100 degrees C for ambient -40 to +70 degrees C, and T135 degrees C for ambient -40 to +80 degrees C, with Ex tb IIIC IP67 dust protection. The certificate numbers are Baseefa08ATEX0265X and IECEx BAS08.0068X, and the flammable sensor conforms to EN 60079-29-1.
Wiring of 2106B1200
The head has three connections: brown is the supply to the active bead, blue is the non-active compensator side, and white is the signal. In the standard junction box they land on the +VE, signal and -VE terminals going to the controller. The family also has a ppm version, the 2106B1205, which reads 0 to 10 percent LEL, and a converter listed as 2106B1110 that turns a catalytic bridge into a 4 to 20 mA signal.
How 2106B1200 differs from the other flammable heads
- 2106B1201: same 0 to 100 percent LEL sensor with an M25 thread.
- 2106B1202: M26 thread; 2106B1203: M26 with a VQ1AB pellistor.
- 2106B1204: three-quarter inch NPT thread.
- 2106B1205 and 2106B1209: 0 to 10 percent LEL ppm version in M20 and NPT.
- High temperature heads, for example 2106B2310, extend operation to +150 degrees C and are described separately.
Because the bead is catalytic, the sensor responds to a wide range of flammable gases and vapours, but the response is calibrated for one target gas. The XCD transmitters treat catalytic heads as flammable sensors numbered 1 to 8 for different calibration gases, with default methane in the 0 to 100 percent LEL range, and the same principle applies when this head is calibrated on a Honeywell controller: the span gas you apply defines which reading is accurate. For gases not on the calibration list, apply the correction factors given in the Honeywell manual rather than assuming a one-to-one reading.
The mV bridge output is also the reason for cable limits. A three-wire bridge is more sensitive to cable resistance than a 4 to 20 mA loop, because the supply current of up to 200 mA flows through the same conductors as the signal reference. Use a cable size that keeps the voltage at the head within its working range and keep the junction box close where possible; the XCD RFD transmitter lists maximum catalytic cable lengths from 356 metres on 0.5 mm squared up to 1636 metres on 2.5 mm squared for its own installations, which gives a useful sense of scale.
Typical applications of 2106B1200
Pump rooms and compressor shelters, fuel storage areas, hydrocarbon processing skids, gas-fired boiler houses, battery-charging areas with hydrogen risk, solvent stores and paint-spray enclosures in factories. In Oman and the GCC the 5-year typical life makes it a lower-cost choice for large point-detector grids, with alarm levels commonly set at 20 and 40 percent LEL, the defaults used on the XCD range.
Installation and commissioning
Mount through a suitable Ex d or Ex e junction box such as the Bartec box 00780-A-0100, which has one 25 mm and three 20 mm entries and an earth continuity plate. Let the head warm up for less than ten minutes, then zero in clean air and span with a calibration gas through a flow housing.
The head’s accuracy is expressed as stability figures rather than a single tolerance: zero drift of less than plus or minus 3 percent of full scale per year and span drift of less than plus or minus 3 percent of full scale per year. Together with a five-year typical life this is a comfortable profile for a catalytic bead, and it explains why operators leave Sensepoint LEL heads on a six- or twelve-month calibration cycle. Keep a record of the zero and span readings at each visit so that slow loss of sensitivity is visible well before it reaches the end of life.
Maintenance notes for 2106B1200
Honeywell gives a typical life of five years, after which the head is simply replaced. Record each calibration, check for blocked flame arresters and replace the head when sensitivity can no longer be restored. Specify the exact thread: the 2106B1200 only fits M20 entries.
Documents and quotation
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The Sensepoint datasheet is available with your quotation. Send an RFQ stating 2106B1200, the quantity and the delivery location, plus the junction box thread.
Datasheets & Documents
- Datasheet Sensepoint Gas Detector Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell 2106B1200 Sensepoint Flammable Sensor
Answers from our engineering team on installation, compatibility and integration.
01What type of output does Honeywell 2106B1200 have?
It has a three-wire millivolt bridge output rather than a 4 to 20 mA loop, with a supply of 200 mA at 0.7 W maximum.
02What measuring range does the 2106B1200 cover?
It covers 0 to 100 percent of the lower explosive limit as a catalytic bead sensor with an M20 thread.
03What is the operating temperature of the 2106B1200?
The datasheet lists -40 to +80 degrees C for the flammable Sensepoint head, with certified temperature classes T85, T100 and T135 degrees C.
04How is the 2106B1200 different from 2106B1201 and 2106B1204?
They are the same 0 to 100 percent LEL sensor with different threads: 2106B1201 is M25 and 2106B1204 is three-quarter inch NPT, while the 2106B1200 is M20.
05How long does the 2106B1200 last?
Honeywell gives a typical operating life of five years and a storage life of over five years when kept in original sealed packaging.


















Reviews
There are no reviews yet.