The Honeywell SLXL-ESNGXX is the three-quarter inch NPT version of the Searchline Excel Edge. Where its sister SLXL-ESMGXX has M25 entries, the SLXL-ESNGXX has NPT threaded entries for conduit wiring, which is the practice on projects following North American standards. It is a long-range infrared open path flammable gas detector in stainless steel, including a small stainless steel mount and bracket and a plastic sunshade, with global approvals including UL.

What the SLXL-ESNGXX specification says

Parameter Value
Gas Hydrocarbons: methane, ethane, propane, butane, pentane, hexane, ethylene, propylene
Range 0 to 5 LEL.m
Recommended alarms Low 1 LEL.m, high 3 LEL.m; minimum 0.5 LEL.m
Path length 60 m to 330 m (196 ft to 1082 ft)
Response T90 less than 3 seconds
Analog output 4 to 20 mA; 1 mA fault; 2 mA inhibit; 3 mA warning; 21 mA over range
Operating temperature -55 to +75 degrees C
Supply 24 VDC nominal (18 to 32 VDC)
Power, transmitter 3.8 W above +30 degrees C; 5.6 W from +30 to -30 degrees C; 11.8 W below -30 degrees C
Power, receiver 3.0 W / 4.8 W / 7.4 W over the same bands
Outputs 4 to 20 mA with HART, fault relay, alarm 1 and alarm 2 relays, Modbus, Bluetooth
Relay rating 32 V, 2 A resistive
Humidity 0 to 99 percent RH, non-condensing
Repeatability +/-0.4 LEL.m
Warm-up Under 5 minutes operational, under 1 hour fully stabilised
Weight Receiver 6.1 kg, transmitter 6.0 kg
Dimensions 103 mm diameter x 325 x 180 mm
Ingress protection IP66/67, Type 4X
Safety SIL 2 certified by TUV SUD to EN 61508
Ex marking IECEx Ex db ia IIC T4 Gb; Ex db eb ia IIC T4 Gb; Ex tb IIIC 100 degrees C Db

Approvals and certification of SLXL-ESNGXX

The datasheet lists cULus Class I Division 1 Groups B, C and D T4 for Ta -55 to +75 degrees C, Class II Division 1 Groups E, F and G T4 for Ta -55 to +55 degrees C, Class III Division 1, and Class I Zone 1 AEx db ia IIC T4 Gb and AEx db eb ia IIC T4 Gb, plus Zone 21 AEx tb IIIC T100 degrees C Db. IECEx lists Ex db ia IIC T4 Gb for flameproof installations and Ex db eb ia IIC T4 Gb for increased safety installations, certificate IECEx ULD 18.0016X. Performance approvals are to ANSI, FM, IEC and EN 60079-29-4, and functional safety is SIL 2 certified by TUV SUD. The unit is also approved to FCC and IC, RoHS and China RoHS.

Why choose SLXL-ESNGXX

  • Conduit-based wiring with three-quarter inch NPT entries.
  • Path length up to 330 metres (1082 feet), minimum 60 metres.
  • Fog performance which Honeywell compares favourably with other NDIR and laser open path detectors.
  • Bluetooth for non-intrusive set-up with an intrinsically safe phone and the Honeywell Fixed Platform App.
  • Modbus, HART, relays and 4 to 20 mA in one unit.

SLXL-ESNGXX compared with the M25 version

Only the entry thread changes. Both versions list the same range 0 to 5 LEL.m, recommended alarms of 1 and 3 LEL.m, repeatability of plus or minus 0.4 LEL.m and temperature drift of plus or minus 0.2 LEL.m at zero and plus or minus 0.5 LEL.m at 3 LEL.m over -40 to +65 degrees C. Check which thread your conduit or glands use before ordering.

Installing SLXL-ESNGXX

Fit each of the transmitter and receiver on the universal bracket, with the mount plate adaptor weighing 3.71 kg and measuring 210 by 210 by 127 mm available as an accessory item. The weights are 6.1 kg for the receiver and 6.0 kg for the transmitter, so plan strong posts. The large adjustable mounting bracket is 2331B1020, the alignment scope is 2017B0299 and the stainless steel sunshade 2017B0113.

Open path detection with the SLXL-ESNGXX is measured in LEL.m: the concentration of gas multiplied by the length of beam it occupies. The Honeywell datasheet recommends a low alarm of 1 LEL.m and a high alarm of 3 LEL.m, with a minimum alarm setting of 0.5 LEL.m, and notes ppm.m equivalents in the manual. Because the SLXL-ESNGXX has a minimum path of 60 metres and a maximum of 330, the same alarm setting corresponds to a very different cloud thickness on a short run than on a long one, and the commissioning record should state the path length used.

Environmental limits are broad. The operating and storage temperature range is -55 to +75 degrees C with DNVGL-CG-0339 location class B, humidity is 0 to 99 percent RH non-condensing, pressure is 91.5 to 105.5 kPa non-compensated, and the enclosure is rated IP66/67 and Type 4X. The unit resists salt mist and sulphuric atmosphere for 15 to 60 minutes of exposure, which is relevant for coastal and offshore Gulf sites. Power consumption varies with temperature, from 3.8 W for the transmitter above +30 degrees C to 11.8 W below -30 degrees C, because the optics are heated in cold conditions.

Testing, maintenance and spares

Honeywell lists functional test filters 2017B0218, a filter extender 2017D0226 and a gassing test cell 2017B0185 for checks, and spares including terminal block sets 2331B1150 and antenna covers 2331B1160 in packs of five. An intrinsically safe Android device is offered with camera 188-200-010 or without 188-200-020, with chargers 188-200-120 and 188-200-130.

Output signals and diagnostics of SLXL-ESNGXX

The 4 to 20 mA output is linearised to 0 to 5 LEL.m, fault is signalled at 1 mA, inhibit at 2 mA, warning at 3 mA and over range at 21 mA. Diagnostic features include window clarity and alignment accuracy, with automatic reporting and full logging of alarms, events and maintenance actions. The status ring is a high-visibility LED halo.

Documents and quotation

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We can include the Edge datasheet with the quotation. Send an RFQ for SLXL-ESNGXX, the quantity, the path length and the delivery location.

Other Models in the Searchline Edge Range

Seven Star LLC supplies models from the Searchline Edge range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Honeywell SLXL-ESMGXX Searchline Excel Edge Long Range M25Fire & Gas DetectorsView details
Honeywell SLXL-ESNGXX Searchline Excel Edge Long Range NPTFire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Searchline Excel Edge Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).

Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.

Honeywell company profile

Origins 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927
Brands in our range Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance
Gent Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005
Elster Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015

Milestones

  • 1885: The Butz thermostat business starts in Minneapolis.
  • 1927: It merges with Mark Honeywell's company.
  • 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
  • 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.

Honeywell products we list

Family Models Typical use
Fixed gas detectors Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID Flammable, toxic and VOC gas detection in process areas
Sensors, flame detection and control SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel Replacement sensors, fire detection and gas detection control panels
Transmitters and flow SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis Process pressure and mass flow measurement
Elster gas metering Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display Gas meters, volume correction and fiscal flow computing
Gent fire alarm systems Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell Addressable and conventional fire alarm systems in buildings and plants
Chadwick-Helmuth rotor track and balance 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor Helicopter rotor track and balance and propeller balancing

Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.

Where Honeywell products are used

In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.

Ordering Honeywell products: what we need

Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.

Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.

FAQ

Questions about the Honeywell SLXL-ESNGXX Searchline Excel Edge Long

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between SLXL-ESNGXX and SLXL-ESMGXX?
SLXL-ESNGXX has three-quarter inch NPT cable entries, while SLXL-ESMGXX has M25 entries. Both are stainless steel with global approvals.
02What gases can SLXL-ESNGXX detect?
It detects hydrocarbon gases including methane, ethane, propane, butane, pentane, hexane, ethylene and propylene, over a range of 0 to 5 LEL.m.
03What safety integrity level does SLXL-ESNGXX have?
The datasheet states SIL 2 certified by TUV SUD to EN 61508.
04Which accessories come with SLXL-ESNGXX?
The listed description includes a small stainless steel mount and bracket and a plastic sunshade.
05How is SLXL-ESNGXX configured?
It has Bluetooth connectivity to pair with an intrinsically safe Android device running the Honeywell Fixed Platform App, plus HART and Modbus.