Honeywell MultiRAE Pro PGM-6248 Portable Multi-Gas Monitor
Description
Honeywell MultiRAE Pro PGM-6248 portable multi-threat monitor
The Honeywell MultiRAE Pro (model PGM-6248) is a pumped portable monitor that combines gas detection with optional gamma radiation measurement. It accepts more than 25 interchangeable, field-replaceable intelligent sensors: gamma radiation, photoionization detectors (PID) in ppm and ppb ranges for volatile organic compounds, electrochemical sensors for toxic gases and oxygen, catalytic and NDIR sensors for combustibles, and an NDIR sensor for CO2. Up to six threat types can be monitored at the same time.
The datasheet positions the device for HazMat response, civil defense, industrial safety, environmental work and semiconductor plants, and it can be ordered with or without wireless. Seven Star LLC supplies the Honeywell MultiRAE Pro PGM-6248 in Oman and the GCC as an independent supplier in Muscat.
Reading the PGM-6248 model number
The ordering section of the datasheet gives the model as PGM-6248 and states that wireless and non-wireless configurations exist. Detailed part numbers for monitors, sampling kits, calibration kits, gas, sensors and spares are listed in a separate portables pricing guide, so your RFQ should list the sensor lineup you need rather than only the model.
PGM-6248 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Honeywell (RAE Systems) / PGM-6248, MultiRAE Pro |
| Size and weight | 193 x 96.5 x 66 mm; 880 g (31 oz) |
| Sensors | Over 25 intelligent, interchangeable sensors; two-gas combination sensor needed for a six-gas configuration |
| Display | Monochrome graphical LCD, 128 x 160 pixels, backlit, automatic screen flip |
| Sampling | Built-in pump, about 250 cc/min average, automatic shutoff in low flow |
| Battery options | Rechargeable Li-ion about 12 h (under 6 h recharge); extended Li-ion about 18 h (under 9 h recharge); alkaline adapter 4 x AA about 6 h (non-wireless figures) |
| Alarms | Multi-tone buzzer 95 dB at 30 cm, vibration, flashing red LEDs, on-screen indication; Man Down Alarm with remote wireless notification |
| Datalogging | 6 months for 5 sensors at 1-minute intervals; user interval 1 to 3,600 s |
| Wireless (optional) | IEEE 802.15.4 sub-1 GHz and Wi-Fi 802.11 b/g; about 100 m to a RAELink3 Z1 mesh modem, about 200 m to EchoView Host, RAEMesh Reader or RAEPoint |
| Operating conditions | –20 to +50 °C, 0 to 95 % RH non-condensing, IP 65 |
| Approvals listed | CSA Class I Div. 1 Groups A to D T4; ATEX II 1G Ex ia IIC T4 Ga; IECEx Ex ia IIC T4 Ga; MIL-STD-810G and 461F compliance |
| Warranty | 4 years on liquid O2 sensors; 3 years on CO and H2S; 2 years on non-consumable parts and catalytic LEL; 1 year on other sensors and consumables |
Sensor ranges available for the PGM-6248
| Sensor | Range | Resolution |
|---|---|---|
| Gamma radiation (CsI scintillator) | 0 to 20,000 µRem/h | – |
| PID VOC 10.6 eV (extended range) | 0 to 5,000 ppm | 0.1 ppm |
| PID VOC 10.6 eV (ppb) | 0 to 2,000 ppm | 10 ppb |
| Catalytic LEL | 0 to 100 % LEL | 1 % LEL |
| NDIR methane | 0 to 100 % LEL or 0 to 100 % vol. | 1 % LEL / 0.1 % vol. |
| CO2 NDIR | 0 to 50,000 ppm | 100 ppm |
| H2S | 0 to 100 ppm | 0.1 ppm |
| CO | 0 to 500 ppm (extended 0 to 2,000 ppm) | 1 ppm (10 ppm) |
| NH3 | 0 to 100 ppm | 1 ppm |
| Cl2 | 0 to 50 ppm | 0.1 ppm |
| O2 | 0 to 30 % vol. | 0.1 % vol. |
The datasheet also lists sensors for chlorine dioxide, ethylene oxide, formaldehyde, hydrogen cyanide, methyl mercaptan, nitric oxide, nitrogen dioxide, phosphine and sulfur dioxide.
How the PGM-6248 works with its sensors and the network
Each sensor stores its own calibration data, so a sensor can be swapped in the field without sending the whole instrument away. The built-in pump draws air through a probe and past the sensors, which allows sampling of confined spaces and hard-to-reach points. A PID reads volatile organics in ppm or ppb, while electrochemical and NDIR sensors cover toxic gases and combustibles.
In the wireless version the instrument reports readings, alarms and a Man Down status to Honeywell remote monitoring software through ProRAE Guardian or an EchoView Host system. Fully automatic bump testing and calibration is possible with the AutoRAE 2 station.
Where the PGM-6248 fits and related Honeywell instruments
The MultiRAE Pro sits between the four-gas clip detectors and the transportable AreaRAE Plus area monitor. For single-sensor VOC work Honeywell offers the MiniRAE 3000 and ppbRAE 3000+, and for four-gas wearable use the MicroRAE and BW MicroClip. Related infrastructure includes the RAELink3 Z1 modem and the AutoRAE 2 test and calibration station.
PGM-6248 selection and ordering checklist
- Target gases, ranges and whether radiation or PID sensors are needed.
- Wireless or non-wireless configuration, and the monitoring software available on site.
- Battery type for shift length; extended Li-ion for 18 hours.
- Sampling accessories (probe, hose, filters) and calibration gas kits.
- Hazardous-area certificate required for the site.
Operation, calibration and maintenance of the PGM-6248
After charging, switch on and wait for the sensor warm-up; the screen then shows readings, the PID correction factor and the compliance indicator. Run a bump test before each work shift and calibrate on the schedule your procedure sets. The datasheet recommends calibrating a sensor on installation.
Keep the pump inlet filter clean, check for leaks in the sampling line and observe the sensor warranty periods. Because the PID lamp and catalytic LEL sensors can be affected by contaminants, avoid exposure to silicones and high concentrations of corrosive gases.
Typical applications of the PGM-6248 in Oman and the GCC
A pumped multi-gas monitor is used before confined-space entry at tanks, vessels, sumps and pipelines, during turnaround work in refineries and gas plants, in hazmat and civil-defense response, and for environmental and wastewater surveys. The PID suits VOC leak screening in petrochemical sites, and the toxic and combustible sensors cover typical oil-and-gas hazards such as H2S and LEL.
Information to send with an RFQ for the PGM-6248
- Sensor list with target gases and ranges.
- Wireless requirement and the host software used.
- Quantity, battery and charging accessories.
- Calibration gas and AutoRAE 2 needs.
- Delivery location.
Documents and quotation
The Honeywell MultiRAE Pro datasheet is attached on this page with the specification and sensor tables.
Send the sensor list and quantity, and Seven Star LLC will quote the Honeywell MultiRAE Pro PGM-6248.
Other Models in the Honeywell Portable Gas Range
Seven Star LLC supplies models from the Honeywell Portable Gas range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell BW MicroClip XL and X3 Four-Gas Detectors | Fire & Gas Detectors | View details |
| Honeywell MultiRAE Pro PGM-6248 Portable Multi-Gas Monitor | Fire & Gas Detectors | You are viewing this model |
| Honeywell MicroRAE Wireless Portable Four-Gas Detector | Fire & Gas Detectors | View details |
| Honeywell AreaRAE Plus Transportable Multi-Gas Area Monitor | Fire & Gas Detectors | View details |
| Honeywell RAELink3 Z1 Wireless Modem with GPS | Fire & Gas Detectors | View details |
| Honeywell QRAE 3 Wireless Pumped or Diffusion Multi-Gas Monitor | Fire & Gas Detectors | View details |
Datasheets & Documents
- Datasheet Honeywell PGM-6248 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell MultiRAE Pro PGM-6248 Portable Multi-Gas
Answers from our engineering team on installation, compatibility and integration.
01What is the Honeywell MultiRAE Pro PGM-6248?
It is a pumped portable monitor with over 25 interchangeable sensors, including PID, toxic, oxygen, combustible, CO2 and gamma radiation sensors, with optional wireless.
02How many threats can it monitor at once?
The datasheet states up to six threat types at a time, and a two-gas combination sensor is required for a six-gas configuration.
03What sampling method does it use?
It has a built-in pump with an average flow of about 250 cc/min and an automatic shutoff in low-flow conditions.
04What battery runtime can be expected?
About 12 hours with the standard Li-ion pack, about 18 hours with the extended pack and about 6 hours with the alkaline adapter, for non-wireless units.
05Can the instrument calibrate automatically?
Yes. It is compatible with the AutoRAE 2 Automatic Test and Calibration System for fully automatic bump testing and calibration.


















Reviews
There are no reviews yet.