Honeywell XNX-AMSV-NNCB1 XNX Transmitter with MPD Catalytic
Description
XNX-AMSV-NNCB1 is the example part number that Honeywell uses in the XNX datasheet to explain its order code, which makes it a good place to learn how the XNX is configured. It is an XNX transmitter with HART over 4 to 20 mA, ATEX and IECEx approval, five M25 entries, painted 316 stainless steel, the mV personality, no output options, no local HART and an MPD catalytic bead sensor for 0 to 100 percent LEL.
Segment by segment: XNX-AMSV-NNCB1
| Segment | Value | Meaning |
|---|---|---|
| Segment | Value | Meaning |
| A | ATEX and IECEx | Hazardous-area approval |
| M | M25 | Five M25 cable entries |
| S | 316 stainless steel | Enclosure material, painted |
| V | mV | Interface for millivolt sensors such as MPD, Sensepoint HT and PPM, and Model 705 |
| N | No option | No relay, Modbus or Foundation Fieldbus module |
| N | No local HART | No local IS HART port |
| CB1 | Catalytic bead | MPD sensor, 0 to 100 percent LEL, supplied fitted to the bottom entry |
What the MPD sensor is
The Multi Purpose Detector is a serviceable stainless steel sensor housing with plug-in catalytic and infrared sensor cartridges. In the CB1 configuration it carries a catalytic bead cartridge reading 0 to 100 percent LEL. Honeywell states that MPD sensors are supplied fitted to the bottom entry when ordered with the transmitter, while other sensors are supplied separately. Infrared MPD options in the same table are IF1 for hydrocarbons, IV1 for methane 0 to 100 percent LEL or 0 to 5 percent by volume, and IC1 for carbon dioxide 0 to 5 percent by volume.
Specification of XNX-AMSV-NNCB1
| Parameter | Value |
|---|---|
| Supply | 16 to 32 VDC, 24 VDC nominal |
| Power | 6.5 W maximum |
| Weight | Approx. 5 kg for stainless steel |
| Certification | ATEX II 2(1) G Ex d [ia IIC Ga] IIC T4/T6 Gb; II 2(1) D Ex tb [ia IIIC Da] IIIC T85 Db; IECEx equivalent |
| Housing | Marine-finish painted aluminium alloy or 316 stainless steel, flameproof |
| Dimensions | 160 x 197 x 114 mm |
| Entries | 5 entries: 2 right, 2 left, 1 bottom |
| Ingress protection | IP66, NEMA 4X |
| Operating temperature | -40 to +65 degrees C |
| Humidity | 0 to 99 percent RH, non-condensing |
| Output | Isolated 4 to 20 mA with HART 6.0, sink, source or isolated |
| Accuracy of 4-20 mA | +/-1 percent of full scale |
| Safety | IEC 61508 SIL 2 assessment |
Why XNX-AMSV-NNCB1 differs from XNX-UTAV-NNNNN
The XNX-AMSV-NNCB1 uses an ATEX and IECEx approval and M25 entries, which suits European and Gulf projects built to IEC standards, while XNX-UTAV-NNNNN suits UL and CSA projects. The XNX-AMSV-NNCB1 is stainless steel at about 5 kg compared with aluminium at 2.8 kg, and it includes the MPD catalytic sensor. This makes the XNX-AMSV-NNCB1 ready to use as a complete flammable gas detector once wired.
The enclosure is a flameproof 316 stainless steel casting with a multilingual backlit display. The XNX-AMSV-NNCB1 is rated IP66 and NEMA 4X, operates from -40 to +65 degrees C, and carries SIL 2 assessment to IEC 61508 as well as ATEX performance approvals to EN 60079-29-1. Weight is approximately 5 kg, compared with 2.8 kg for the aluminium alloy version, and the dimensions are 160 by 197 by 114 mm. In coastal oil and gas plants and offshore installations that require stainless steel, the XNX-AMSV-NNCB1 is the version to specify, and it is a convenient reference configuration for any enquiry about other XNX combinations.
When the MPD sensor is mounted on the bottom entry of the XNX-AMSV-NNCB1, installation is simple: mount the transmitter, route power and signal cables through two of the M25 side entries, blank the remaining entries, and wire the 4 to 20 mA and power connections at terminal block TB1. Because the MPD uses plug-in cartridges, the sensor can be serviced on site, which is one of the points Honeywell makes about the XNX: serviceable catalytic and infrared sensors lower the cost of ownership.
Installation
Surface mount using the two lugs, or pipe mount with the kit 1226A0358, or ceiling mount with 1226A0355. The MPD sensor is fitted on the bottom entry, and the remaining four M25 entries carry supply and signal cables. Honeywell’s installation drawing shows dimensions of 160 by 197 by 114 mm for the transmitter.
Operation
The XNX-AMSV-NNCB1 is a transmitter with an on-board personality, so after wiring, use the magnetic switches to set range and alarms; the XNX auto-recognises the sensor type. Choose sink, source or isolated output with the switches on the POD, and use HART tools for diagnostics. Optional modules can be added later in the field by a qualified service engineer.
Outputs and communications are worth restating for this order code. Standard on the XNX-AMSV-NNCB1 is an isolated 4 to 20 mA output with HART 6.0, configurable as sink, source or isolated, with a 4 to 20 mA accuracy of plus or minus 1 percent of full scale. Default current levels are below 1.0 mA for a fault, 4 to 20 mA for normal gas measurement, 2.0 or 4.0 mA while inhibited during configuration, and 22.0 mA at maximum over range, or 3 mA for fault and warning in HART mode. HART can report the gas name and units, raw reading, temperature, supply voltage, calibration status and fault and alarm history, which is useful for remote diagnosis of the XNX-AMSV-NNCB1 on a pipe rack.
For power planning, the XNX-AMSV-NNCB1 draws up to 6.5 W with a catalytic or infrared cell, and the input range is 16 to 32 VDC. Terminals are cage-style pluggable blocks for wire of 0.5 to 2.5 mm squared, roughly 20 to 14 AWG. Honeywell’s typical maximum cable distances for an mV unit with an MPD catalytic sensor are 347 metres on 1.0 mm squared and 1408 metres on 2.5 mm squared, assuming a single transmitter on a supply.
Documents and quotation
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The XNX datasheet is available with our quotation. Send an RFQ naming XNX-AMSV-NNCB1, the quantity and the delivery location.
Installation and Commissioning Planning
Planning ahead shortens downtime when a Honeywell XNX-AMSV-NNCB1 goes into service. Confirm the available mounting space, cable entry or process connection, and the tools and spare seals needed on the day. Keep the existing configuration or calibration data so the new unit can be set up to match, and check that loop drawings and the asset register are updated after the swap. If the installation has to fit a short shutdown window, tell us the date when you request a quotation so that delivery of the Honeywell equipment can be planned around it.
Other Models in the Xnx Range
Seven Star LLC supplies models from the Xnx range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell XNX-UTAI-NNNNN XNX Universal Transmitter IR | Fire & Gas Detectors | View details |
| Honeywell XNX-UTAV-NNNNN XNX Universal Transmitter mV | Fire & Gas Detectors | View details |
| Honeywell XNX-AMSV-NNCB1 XNX Transmitter with MPD Catalytic | Fire & Gas Detectors | You are viewing this model |
Datasheets & Documents
- Datasheet XNX Universal Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell XNX-AMSV-NNCB1 XNX Transmitter with MPD
Answers from our engineering team on installation, compatibility and integration.
01What does the CB1 in XNX-AMSV-NNCB1 mean?
CB1 is the sensor and range code for the MPD catalytic bead sensor covering 0 to 100 percent LEL, supplied fitted to the bottom entry.
02Which approval does XNX-AMSV-NNCB1 carry?
The A means ATEX and IECEx approval, paired with M for five M25 cable entries.
03What material is the XNX-AMSV-NNCB1 enclosure?
S indicates painted 316 stainless steel, and the unit weighs about 5 kg compared with 2.8 kg for aluminium.
04Does XNX-AMSV-NNCB1 have relays or Modbus?
No. The two N letters after the personality mean that no output option and no local HART port are installed, although HART over 4 to 20 mA is standard.
05Why is XNX-AMSV-NNCB1 used as an example in the datasheet?
Honeywell uses it to illustrate how the order code is built, with each segment describing approval, entry, material, personality, option, HART and sensor.