Brand:

AUMA LE 200.1 Linear Thrust Unit (217 kN)

Description

Overview

At the top of the line stands the AUMA LE 200.1: 87 to 217 kN of thrust from an SA 16.2, the highest force in AUMA’s linear thrust series. Strokes of 100, 200, 400 or 500 mm and masses between 45 and 68 kg define the package. Its natural customers operate heavy globe valves, large sliding-stem valves and slide gates, where forces are several times what the LE 50.1 can provide.

Seven Star LLC is the regional supplier and trusted AUMA supplier, and it offers the AUMA LE 200.1 with SA 16.2 or SAR 16.2 actuators to generation, water and industrial clients in the Sultanate of Oman and the GCC. Thrust, travel and thread are verified against the valve drawing first, then AUMA documents, warranty and commissioning support follow with the order.

Operating Principle of the AUMA LE 200.1

Inside the AUMA LE 200.1 the SA 16.2 turns a drive nut that moves a threaded spindle, and a coupling stud carries the motion to the valve stem. The thread holds the load at standstill. AUMA’s torque-to-thrust factor for this size is 4.6, the largest in the series, so 200 Nm at the actuator corresponds to about 43 kN. A clockwise-rotation-extends arrangement is standard and the opposite arrangement is a choice.

The open-close thrust corridor is 87 to 217 kN with short peaks to 300 kN. The regulating SAR 16.2 offers 110 to 217 kN, with 87 kN rated for modulating torque. Speed at the stem is 32 mm per minute at 4 rpm, 256 mm per minute at 32 rpm and 360 mm per minute at the 45 rpm ceiling.

Engineering Design of the AUMA LE 200.1

Mounting to the actuator is by F16 flange; toward the valve a DIN 3358 flange and a 48 x 8 left-hand stem thread are used. Mass is 45 kg at 100 mm travel, 50 kg at 200 mm, 62 kg at 400 mm and 68 kg at 500 mm, excluding actuator and base.

The casing is rated IP67 and coated for KS corrosion class with a two-component iron-mica finish. Ambient limits are -25 and +80 degrees Celsius, with higher and lower options on request. Operation is short-time duty S2 for 15 minutes, with full load kept to the opening and closing moments.

Travel, Mass and Thrust Table for the AUMA LE 200.1

AUMA’s data sheet gives the AUMA LE 200.1 the following combinations of travel and mass.

Maximum stroke Approximate weight Min. thrust (SA) Max. thrust (SA)
100 mm 45 kg 87 kN 217 kN
200 mm 50 kg 87 kN 217 kN
400 mm 62 kg 87 kN 217 kN
500 mm 68 kg 87 kN 217 kN

Every travel option offers the same 87 to 217 kN thrust band; only mass and stem travel change.

Key Features

The AUMA LE 200.1 is the top of the AUMA linear thrust unit range:

  • Thrust of 87 to 217 kN, tolerating peaks of 300 kN.
  • Travel lengths of 100, 200, 400 and 500 mm.
  • Paired with the SA 16.2 for on-off and the SAR 16.2 for regulating duty (110 to 217 kN).
  • 48 x 8 left-hand stem thread and the series’ highest factor, 4.6.
  • F16 actuator interface and DIN 3358 valve flange.
  • Stem velocity between 32 and 360 mm/min.
  • Mass of 45 to 68 kg depending on travel.
  • Self-holding spindle, IP67 housing and KS finish.

Industrial Applications

Heavy globe valves in steam systems, large sliding-stem valves on process lines and slide gates in bulk-material and water works can demand up to 217 kN, and the AUMA LE 200.1 supplies it. Plants near Sohar and Duqm that already use AUMA controls favour it, and the 500 mm travel option fits valves with a long stem stroke.

As trusted AUMA supplier, Seven Star LLC delivers the LE 200.1 and SA 16.2 or SAR 16.2 actuators to EPC contractors and utilities in Oman, Salalah and across the GCC. See also the AUMA LE linear thrust unit overview, the AUMA GST spur gearbox family for gearbox solutions and the AUMA SAR 14.1 modulating actuator.

Related pages on our site: AUMA LE 100.1, AUMA LE 50.1 and AUMA PROFOX-L compact smart linear actuator.

Technical Specifications

The AUMA LE 200.1 is the largest of the six LE types in AUMA’s sheet, and its values follow.

Parameter Specification
Model AUMA LE 200.1
Construction Spindle-type linear thrust unit
Drive SA 16.2 on-off; SAR 16.2 regulating
Travel options 100, 200, 400, 500 mm
Thrust 87 to 217 kN (SAR: 110 to 217 kN)
Peak thrust tolerated 300 kN
Actuator interface F16, DIN 3358 valve flange
Stem thread 48 x 8 LH
Torque-to-thrust factor 4.6
Stem velocity 32 to 360 mm/min
Mass 45 to 68 kg
Duty rating S2 – 15 min
Protection and climate IP67; -25 to +80 °C

With a factor of 4.6, thrust of 87 to 217 kN corresponds to roughly 400 to 998 Nm of actuator torque, which is why the SA 16.2 is the paired drive.

Stroke Time and Thrust Margins for the AUMA LE 200.1

The LE 200.1 turns the SA 16.2 speed range into stem speeds of 32 mm/min at 4 rpm, 44 at 5.6 rpm, 64 at 8 rpm, 88 at 11 rpm, 128 at 16 rpm, 176 at 22 rpm, 256 at 32 rpm and 360 mm/min at the 45 rpm limit. A 200 mm travel needs about six minutes at the slowest speed and about 47 seconds at 256 mm/min, and the longest 500 mm travel takes about 83 seconds at 360 mm/min. With a minimum thrust of 87 kN the unit is intended for valves that really need it, and AUMA’s plus or minus 20 percent tolerance on the thrust settings means that valves operating near the 217 kN maximum should be sized with a clear margin below the 300 kN exceptional limit.

Information Seven Star LLC Needs to Quote the AUMA LE 200.1

To select the correct LE 200.1 configuration we ask for the maximum seating and unseating force of the valve, the stem travel of 100, 200, 400 or 500 mm, the stem thread and the required closing time. With the torque-to-thrust factor of 4.6 we convert the thrust into the torque the SA 16.2 must deliver, and we then check whether an on-off SA 16.2 or a regulating SAR 16.2 matches the duty cycle. We also confirm the ambient temperature against the standard range of -25 to +80 degrees Celsius, the coupling stud and DIN 3358 flange against the valve yoke, and the mass of 45 to 68 kg against the support structure. This short checklist avoids resizing after delivery and gives the LE 200.1 a documented basis for commissioning in Oman and the GCC.

Request a Quote for AUMA LE 200.1

Send Seven Star LLC an enquiry for the AUMA LE 200.1 that includes valve travel, required force, stem thread and duty. We reply with the actuator pairing, the downloadable AUMA data sheet and a delivery plan; as a supplier of AUMA products for Oman and the GCC we confirm lead time at quotation.

Datasheets & Documents
  • PDF Datasheet AUMA LE 12.1 - LE 200.1 with SA 07.2 - SA 16.2 Technical Data Sheet (open-close duty) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA LE 200.1 Linear Thrust Unit (217 kN)

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum thrust of the AUMA LE 200.1?
With the SA 16.2 the AUMA LE 200.1 provides a maximum thrust of 217 kN and a minimum of 87 kN, with up to 300 kN permissible in exceptional cases.
02What strokes can I choose for the AUMA LE 200.1?
AUMA lists strokes of 100, 200, 400 and 500 mm, and higher strokes are available on request.
03Which actuator drives the AUMA LE 200.1?
The SA 16.2 drives it for open-close duty and the SAR 16.2 for modulating duty.
04How heavy is the AUMA LE 200.1?
It weighs 45 kg for the 100 mm stroke, 50 kg for 200 mm, 62 kg for 400 mm and 68 kg for 500 mm, excluding the actuator and base.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC, supplying genuine linear thrust units with local support.