Brand:

Rosemount 08732-0753-1003 Combination Cable 20/18 AWG

Description

Combination cable 08732-0753-1003: signal and coil drive in a single jacket

Rosemount 08732-0753-1003 is the combination cable for remote Rosemount 8700 Series magnetic flowmeters. According to the datasheet it joins a 20 AWG electrode cable and an 18 AWG coil drive cable and is supplied by the foot; the metric-length counterpart is 08732-0753-2004. Using one cable instead of two halves the pulling work and cuts the number of glands at the sensor and transmitter.

The datasheet adds a compliance point that makes this cable more than a convenience: the combination cable is required in order to meet the EN 61326-1:2006 industrial electromagnetic compatibility requirements for the 8732 and the 8712 with sensors.

Key limits and data

Parameter Value
Part number 08732-0753-1003
Description Combination Cable, Electrode Cable (20 AWG) and Coil Drive Cable (18 AWG), per foot
Metric version 08732-0753-2004
Maximum recommended length less than 330 ft (100 m)
High-signal systems not recommended
EMC compliance required to meet EN 61326-1:2006 industrial for 8732 and 8712
Order length range 5 to 1000 ft (1.5 to 300 m) in general, subject to the 330 ft limit for combination cable
Separate alternative 08712-0061-0001 plus 08712-0060-0001
Transmitters served remote 8732, 8712

The datasheet states the standard configuration of integrally mounted 8732 transmitters is factory wired and that remote arrangements need a single conduit connection at the sensor when a combination cable is used, because both electrode and coil drive conductors travel in one jacket. In the 8732 remote version, with a junction box option such as a potted junction box supplied with combination cable in lengths of 50 to 300 feet (codes R05 to R30), the factory can also supply the cable length with the sensor. For other lengths, or for replacement, the part number above is the reference.

How 08732-0753-1003 differs from the separate cables

The separate pair, 08712-0061-0001 for signal and 08712-0060-0001 for coil drive, uses 20 AWG and 14 AWG conductors and can reach up to 1000 ft (300 m) in the standard systems. 08732-0753-1003 reduces the coil drive to 18 AWG to fit in one jacket and therefore the datasheet limits it to less than 330 ft (100 m) and rules it out for high-signal magmeters. Use the separate pair for a long run or a pulsed-DC high-signal system, and the combination cable for short, neat runs that must meet the EMC standard.

System examples in Oman and the GCC

Short remote runs occur where the sensor sits in a valve chamber near a pumping station and the 8712 sits in a control kiosk a few tens of metres away, or where an 8732 is moved off a vibrating line into a remote configuration. The datasheet gives IP68 and 30 ft (10 m) continuous submergence capability for sensors with proper glands, relevant to flood-prone chambers.

In practice the choice of this cable comes down to three questions: is the system high-signal (then no), is the run longer than 330 ft (then no), and does the project need the EMC compliance documented for the transmitters (then yes, the combination cable is required). If the answer pattern is no, no, yes, the combination cable is correct. If the run is long or the system is pulsed DC high-signal, specify the separate 14 AWG and 20 AWG cables instead and keep equal lengths.

Installation checklist

  • Confirm the total cable length of 08732-0753-1003 is below 330 ft (100 m).
  • Check that the system is not a high-signal 8707/8712H type.
  • Terminate the electrode pair and coil drive pair at the labelled terminals on both ends.
  • Use metal-compatible conduit and sealed glands at the sensor junction box.
  • Record the installed length; both ends must keep the combination cable together.

For remote 8732 installations ordered with a potted junction box, the datasheet lists lengths of 50 to 300 feet in 50-foot steps with the combination cable preattached. If an extra length is needed on site, order it by the part number on this page and cut it to the required length, keeping within the 330 ft (100 m) total limit that applies to this cable type.

Diagnostics after installation

The 8732 and 8712 transmitters include basic diagnostics such as coil fault, empty pipe and reverse flow, advanced Suite 1 diagnostics such as grounding or wiring fault and high process noise, and Suite 2 Smart Meter Verification. After commissioning, run the meter verification and file the report. A change in coil resistance or electrode impedance later on is a prompt to inspect the cable first.

Transmitter ambient limits and ratings are also relevant to cable routing: the 8732 transmitter is rated to type 4X and IP66, and its remote mounting needs a 2-in. pipe or panel. Where the transmitter is mounted outdoors under Gulf sun, the cable jacket will be exposed along part of the run, so use conduit or tray covers.

Care of the cable

Avoid bending below the manufacturer’s recommended radius, avoid sharp edges at cable tray exits, and keep ends capped until termination. When replacing, replace the whole run rather than splicing, because splices create noise paths for the millivolt signal.

Mark both ends of the cable with the tag of the flowmeter and the cable part number. The combination cable contains a signal pair and a drive pair together, so it is easy to swap the two when terminating if the colour code is not followed; the sensor installation manual lists the terminal designation for each conductor. A continuity check from each end, plus insulation resistance to ground, takes only minutes and avoids a repeat call-out.

Documents and quotation

The 8700 Series datasheet listing 08732-0753-1003 is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send your RFQ with 08732-0753-1003, the length in feet or metres, the transmitter type and your delivery location in Oman or the GCC.

Datasheets & Documents
  • PDF Datasheet Rosemount 08732-0753-1003 Combination Cable 20/18 AWG Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 08732-0753-1003 Combination Cable 20/18

Answers from our engineering team on installation, compatibility and integration.

01What is Rosemount 08732-0753-1003?
It is the combination cable, electrode 20 AWG and coil drive 18 AWG, supplied by the foot for remote Rosemount 8700 Series magnetic flowmeters.
02What is its metric part number?
08732-0753-2004 is the metric length version of the same combination cable.
03What is the maximum recommended length?
The datasheet says combination signal and coil drive cable should be limited to less than 330 ft (100 m).
04Can it be used with the 8712H/8707 high-signal system?
No. The datasheet states combination cable is not recommended for high-signal magmeter systems.
05Why do some projects need it?
The datasheet states the combination cable is required to meet EN 61326-1:2006 industrial EMC compliance for the transmitters.