- Automation & ControlView all 2,716 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand
Pilz
Pilz is a German family-owned automation company, founded in 1948 by Hermann Pilz as a glass-blowing business in Esslingen. Under his son Peter, it moved into electronic control and monitoring, and in 1987 it launched the PNOZ emergency stop safety relay, which became the most widely used device of its kind. Pilz is headquartered in Ostfildern and employs about 2,500 people. Seven Star LLC lists Pilz PNOZsigma safety relays and the PNOZmulti 2 base unit, and supplies them to machine builders and plants in Oman and the GCC.
Read the full brand profile ↓- 5 products
- 3 categories

5 products
Brand profile
About Pilz
- Founded
- 1948
- Headquarters
- Ostfildern, Germany
- Speciality
- Safety automation systems
- Listed with us
- 5 products in 3 categories
Pilz products by category
Pilz is a German family-owned automation company, founded in 1948 by Hermann Pilz as a glass-blowing business in Esslingen. Under his son Peter, it moved into electronic control and monitoring, and in 1987 it launched the PNOZ emergency stop safety relay, which became the most widely used device of its kind. Pilz is headquartered in Ostfildern and employs about 2,500 people.
Seven Star LLC lists Pilz PNOZsigma safety relays and the PNOZmulti 2 base unit, and supplies them to machine builders and plants in Oman and the GCC.
Pilz company profile
| Founded | 1948, Esslingen, Germany |
|---|---|
| Founder | Hermann Pilz |
| Headquarters | Ostfildern, Germany |
| Ownership | Family-owned |
| Product families | PNOZ s and PNOZ X safety relays, PNOZmulti configurable controllers, PSS 4000 automation, safety sensors and light curtains |
Milestones
- 1948: Hermann Pilz founds the company.
- 1987: The PNOZ safety relay is launched.
- 2002: PNOZmulti is introduced.
Pilz PNOZ families listed here
PNOZsigma relays are narrow units whose operating mode and timing are set with rotary switches on the front. The PNOZ s3 monitors E-STOP buttons and safety gates. The PNOZ s4 has three safety contacts and one auxiliary contact, and the PNOZ s5 adds time-delayed safety contacts with an adjustable delay. The PNOZ m B0 is the base unit of the PNOZmulti 2 configurable safety controller: its safety functions are drawn in the PNOZmulti Configurator software instead of being hard-wired.
Where Pilz safety relays are used
They are found on packaging lines, presses, conveyors and process skids, wherever an emergency stop, guard door, light curtain or two-hand station must remove power safely.
Pilz products we list
Ordering Pilz safety relays: what we need
Send the type and the six-digit order number from the side label, the supply voltage version and the terminal type. For a PNOZ m B0, list the expansion modules fitted beside it. Pilz names the PNOZ m B1 as the alternative base unit, so we check status before quoting.
Facts checked against Pilz's own history leaflet and company profile, October 2026.
Request a Quote for Pilz Products
Looking for Pilz parts not listed here, or pricing for a project? Send us the part numbers and quantities. Seven Star LLC sources genuine Pilz products for customers across Oman and the GCC and replies with a formal quotation.
- Genuine OEM products
- Supply across Oman & the GCC
- Formal quotation from our sales team
Free, no-obligation quotation · takes about 1 minute
Other enquiries: [email protected] · WhatsApp
FAQ
Questions about Pilz
Common questions about Pilz equipment, part numbers and supply to Oman and the GCC.
01How do I identify a Pilz PNOZ relay from its label?
Read two things from the side label: the type, for example PNOZ s4, and the six-digit order number. The order number fixes the supply voltage version and the terminal style, which the type alone does not. A C in the type marks spring-loaded terminals; without it the unit has plug-in screw terminals. Send a photo of the label if any digit is unclear.
02What is the difference between PNOZsigma relays and the PNOZ m B0?
A PNOZsigma relay such as the PNOZ s3, s4 or s5 performs one safety function, selected with rotary switches. The PNOZ m B0 is a small configurable controller. Several safety functions and their logic are created in the PNOZmulti Configurator and loaded into the base unit, and expansion modules add inputs, outputs or fieldbus connections. Choose it when one machine has several safety devices that interact.
03Can a PNOZsigma relay replace an older PNOZ X relay?
Often the safety function can be matched, but it is not a plug-for-plug swap. Housing width, terminal layout, supply voltage and the number of safety and auxiliary contacts differ between the two families. Send the old relay's type and order number. We check it against Pilz documentation, and the changed safety circuit must then be validated by the machine owner.
04Which safety level do Pilz PNOZ relays reach?
The performance level and safety integrity level each relay can reach are stated in its operating manual, together with the characteristic data needed for the calculation. The figure for your machine depends on the complete safety function, including the sensor and the actuator, not on the relay alone. On request we supply the Pilz manual and declaration of conformity for the exact order number.
05Is Seven Star LLC a distributor of Pilz?
No. Seven Star LLC is an independent industrial supplier based in Muscat, not a distributor or agent of Pilz. We source Pilz safety relays and controllers through commercial channels, check the model or order code against the manufacturer's documentation, and provide the manufacturer's datasheet and the certificates the manufacturer issues with the order on request.
















