Cooper Crouse-Hinds N2S2210 N2S Explosionproof Pushbutton Station

Description

Overview

The Cooper Crouse-Hinds N2S2210 is a dead end, factory-sealed heavy duty pushbutton control station from the N2S non-metallic series, configured with two flush round operators legended START-STOP and a 2NO-2NC contact arrangement rated to 600 VAC. Built in the same corrosion-resistant Krydon fiberglass-reinforced polyester body as the wider N2S range, the N2S2210 gives plant electrical teams a complete, ready-to-wire start/stop station in a single lightweight, non-metallic enclosure suited to Class I, Division 2 hazardous process areas.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the N2S2210 pushbutton station to oil and gas, water treatment, and industrial manufacturing operators across Oman and the wider GCC. Every unit is genuine Crouse-Hinds product with full manufacturer traceability, and our technical team supports specification, sizing, and compliant installation for non-metallic hazardous-area control networks throughout the Sultanate of Oman.

Operating Principle

The Cooper Crouse-Hinds N2S2210 integrates two flush round pushbutton operators into a single dead-end Krydon polyester enclosure, each wired to its own momentary contact block: pressing START closes its normally-open contact to energize the associated motor starter coil, while pressing STOP opens its normally-closed contact to de-energize the circuit. Because the entire assembly – enclosure, contact blocks, and legend plate – is factory sealed as a unit, no external conduit sealing fitting is required at the device itself, streamlining commissioning in the field.

For the Cooper Crouse-Hinds N2S2210, the dead-end body style terminates a single 3/4 in conduit hub, making the N2S2210 well suited to installation at the end of a control run near a motor, pump skid, or local control panel. With no moving parts beyond the pushbutton mechanisms themselves and a fully sealed non-metallic body resistant to corrosion, UV exposure, and thermal cycling, the N2S2210 offers a long service life with minimal maintenance in Division 2 process environments.

Engineering Design of the Cooper Crouse-Hinds N2S2210

The Cooper Crouse-Hinds N2S2210 enclosure measures 3-13/16 in wide by 5-3/4 in deep by 7-1/4 in high and is molded from Krydon high-impact-strength fiberglass-reinforced polyester, chosen for its excellent resistance to corrosion, heat, and prolonged sun exposure – important in the high-UV, high-humidity conditions typical of Oman and the wider GCC. The two flush round pushbutton operators are marked START and STOP per standard industrial convention, each connected to a dedicated 2NO-2NC momentary contact set for redundant switching confidence in critical motor control circuits.

On the Cooper Crouse-Hinds N2S2210, surface-mounted via a threaded 3/4 in conduit hub, the N2S2210 is watertight, weatherproof, and dust-tight by design, with no additional gaskets or covers required beyond the factory-sealed body itself. The station is listed to UL 1203, certified to CSA C22.2, and rated NEMA 3/4X/12/7BCD for Class I, Division 2, Groups B, C and D hazardous locations, making it suitable for both indoor process areas and outdoor equipment yards across chemical, petrochemical, and grain handling facilities.

The complete N2S2210 assembly weighs approximately 2.9 lb (1.3 kg), light enough for straightforward one-person mounting on a pump skid, motor starter panel, or local control stand without special lifting equipment. Field wiring and mounting instructions for the station are documented in Crouse-Hinds installation sheet IF 703, and the internal contact block design shares its lineage with the wider Crouse-Hinds EDS series of hazardous-area pilot devices, simplifying spares stocking for sites that already carry EDS selector switches or pilot lights alongside their pushbutton stations. Beyond its UL 1203 listing, the N2S2210 also carries CSA C22.2 certification for the Canadian market, giving specifying engineers a single control station that satisfies both US and Canadian hazardous-area documentation requirements on multinational EPC projects operating across Oman and the wider GCC.

Key Features

The Cooper Crouse-Hinds N2S2210 delivers a complete factory-sealed start/stop station in one compact non-metallic body:

  • Two flush round operators legended START-STOP with independent 2NO-2NC momentary contact sets.
  • Krydon fiberglass-reinforced polyester enclosure resists corrosion, heat, and UV degradation.
  • Dead end, factory-sealed heavy duty design eliminates the need for external conduit seals.
  • 600 VAC voltage rating suitable for direct interface with magnetic starters and contactors.
  • NEMA 3/4X/12/7BCD rating for washdown, outdoor, and dusty industrial environments.
  • Rated for Class I, Division 2, Groups B, C and D hazardous locations per UL 1203 and CSA C22.2.
  • Single 3/4 in threaded conduit hub for straightforward surface mounting.
  • Watertight, weatherproof, dust-tight, and corrosion-resistant construction throughout.

Industrial Applications

The Cooper Crouse-Hinds N2S2210 pushbutton station is specified as a local start/stop control point throughout Division 2 hazardous process areas: chemical plants, oil and gas refineries, paint and varnish manufacturing facilities, gasoline bulk loading terminals, grain elevators and grain processing operations, and wet or corrosive-atmosphere locations where a metallic station would face accelerated wear. Its complete factory-wired configuration reduces field labor compared with assembling individual pushbutton and contact block components.

With fast quotation turnaround and technical support, Seven Star LLC distributes the N2S2210 to EPC contractors, panel builders, and plant maintenance teams across Muscat, Sohar, and the Salalah free zone, supporting both new-build hazardous-area control networks and shutdown/turnaround replacement programs. We supply on request with lead time and availability confirmed at quotation, with full datasheet and UL certification support available for Oman and GCC regulatory submissions.

Technical Specifications

Key specifications for the Cooper Crouse-Hinds N2S2210 pushbutton station, model Cooper Crouse-Hinds N2S2210,:

Parameter Specification
Model N2S2210
Series N2S non-metallic control stations
Legend START-STOP
Contact Configuration 2NO-2NC, momentary
Voltage Rating 600 VAC
Enclosure Material Krydon fiberglass-reinforced polyester
NEMA Rating 3 / 4X / 12 / 7BCD
Hazardous Rating Class I, Division 2, Groups B, C, D
Standards UL 1203; UL 698; CSA C22.2
Dimensions 3-13/16 in W x 5-3/4 in D x 7-1/4 in H
Weight Approx. 2.9 lb (1.3 kg)
Installation Reference Crouse-Hinds sheet IF 703
Brand Cooper Crouse-Hinds (Eaton)

Request a Quote for Cooper Crouse-Hinds N2S2210 N2S Explosionproof Pushbutton Station

Seven Star LLC stocks and supplies the Cooper Crouse-Hinds N2S2210 pushbutton station for immediate quotation and regional delivery across Oman and the GCC. With engineering support in Muscat, we support formal RFQ submissions, confirm lead time and availability at quotation, and provide full technical datasheets on request. Contact our instrumentation and hazardous-area electrical division today for pricing, lead time, and compliance documentation for your N2S2210 requirement.

Related Products

Datasheets & Documents
  • PDF Datasheet Cooper Crouse-Hinds N2S Control Stations Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Conduit bodies stamped Condulet and cast explosionproof boxes carrying the Crouse-Hinds name have been part of hazardous-area electrical work since the company started in Syracuse, USA, in 1897. Seven Star LLC sources and supplies Cooper Crouse-Hinds conduit fittings, sealing fittings, junction boxes, pushbutton stations and receptacles for plants in Oman, checking each catalog number against the manufacturer's documentation. Current production is sold as Eaton's Crouse-Hinds series, so either name may appear on the part you are replacing.

Cooper Crouse-Hinds product families listed here

The catalog numbers on this page follow the manufacturer's own series names:
  • Condulet conduit outlet bodies, such as the Form 8 C28 and the Form 5 LB25
  • EYS conduit sealing fittings (EYS3, EYS5) and ECGJH flexible couplings
  • GUB and GUE explosionproof junction boxes, and the box listed as GUP315
  • EDS and EFS explosionproof control stations and N2S non-metallic, factory-sealed stations
  • Arktite receptacles, for example the 30 A AR342
An MTL 9608 process junction box is listed alongside them.

Where Crouse-Hinds explosionproof equipment is used

Most of these parts belong to rigid conduit systems in classified areas: refinery units, gas compression and metering stations, tank farms, loading racks, paint and solvent handling, and offshore modules across the GCC. The listed series are built around the North American Class and Division system, but the rating differs by item: N2S stations are marked for Class I, Division 2, and the AR342 receptacle is a watertight type for ordinary locations. A Cooper Crouse-Hinds junction box or control station should therefore be selected against the area classification drawing, not by enclosure size alone.

Ordering Cooper Crouse-Hinds parts: what we need

Send the full catalog number from the nameplate or the casting, including every suffix. For conduit bodies and seals, add the hub size and thread, and state the material, iron alloy or copper-free aluminum. For control stations, list the operators, contact blocks and legend plates. For receptacles, give the amperage, the number of wires and poles, and the mating plug. A nameplate photo and the area classification let us confirm the match before quoting.

Frequently Asked Questions

What is the contact configuration of the N2S2210?
The Cooper Crouse-Hinds N2S2210 provides two flush round START-STOP operators, each with its own 2NO-2NC momentary contact set, rated 600 VAC.
What hazardous locations is the N2S2210 rated for?
The N2S2210 is rated for Class I, Division 2, Groups B, C and D hazardous locations, listed to UL 1203, UL 698 and certified to CSA C22.2.
How does the N2S2210 differ from the N2PS1111?
The N2S2210 is a complete two-operator START-STOP station with 2NO-2NC contacts per button, while the N2PS1111 is a single-operator momentary pushbutton with a single 1NO-1NC contact circuit.
Is the N2S2210 suitable for outdoor installation?
Yes, the N2S2210 is watertight, weatherproof, and dust-tight with a NEMA 3/4X/12/7BCD rating, making it suitable for outdoor and washdown environments across the GCC.
Is Seven Star LLC an experienced supply partner for Cooper Crouse-Hinds products?
Yes, Seven Star LLC is an experienced supplier of Cooper Crouse-Hinds in Oman and the GCC, supplying genuine product with full manufacturer traceability and technical support.