Brand: AUMA
AUMA AC 01.2 AUMATIC Microprocessor Actuator Controls
Description
AUMA AC 01.2 microprocessor actuator controls
The AUMA AC 01.2 (AUMATIC) is a microprocessor-based actuator control unit with comprehensive functions. It is mounted on SA .2 multi-turn and SQ .2 part-turn actuators and turns them into configurable, diagnosable field devices. The AC 01.2 suits applications that need self-adapting control functions, data logging, a configurable interface or full integration of valve and actuator into a plant asset management system. Seven Star LLC supplies AUMA actuators and controls in Oman and the GCC as an independent supplier in Muscat; use this page as a guide when preparing an enquiry.
During development of the AC 01.2 the manufacturer put particular emphasis on user-friendliness and on how easily actuators can be integrated into the DCS. A large graphic display allows menu-controlled programming, and with a fieldbus connection the controls can be programmed from the control room.
AC 01.2 technical data
| Parameter | Specification |
|---|---|
| Manufacturer / part number | AUMA / AC 01.2 (AC / ACV actuator controls) |
| Type | Microprocessor-based actuator controls with integral local controls |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C to +70 °C |
| Motor control | Reversing contactors or thyristors |
| Analogue control | 0/4 to 20 mA |
| Fieldbus | Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus, WirelessHART |
| Electrical connection | AUMA plug/socket connector (terminals as alternative); FOC connection for fieldbus |
| Functional safety | Safe end position feedback up to SIL 2 in selected configurations |
Local controls and display
Local controls consist of a lockable selector switch, push buttons and indication lights, together with an LCD for status monitoring and parametrisation support. Setting of the actuator and the controls can be done non-intrusively when the MWG magnetic limit and torque transmitter is fitted, which means the housing does not have to be opened at the valve. A Bluetooth interface to a notebook or Android tablet allows access with the AUMA CDT software. Operation data logging stores events, and the controls can be mounted separately from the actuator on a wall bracket when vibration, heat or access make a direct mounting inconvenient.
Diagnostics and special functions of AC 01.2
- Time-stamped event report
- Torque characteristics logging
- Continuous recording of temperatures and vibration within the actuator
- Counting of starts and motor running times
- Torque bypass to unseat tightly seated valves
- Functions for extending operating times to avoid water hammer, programmable stepping mode
- Process controller (PID) and freely defined intermediate positions
- Behaviour in case of emergency and loss of communication is programmable
- Limit and torque as analogue signals when combined with MWG
Interfaces and system integration
Parallel control inputs accept different voltages (DC/AC) and the programmable potential-free output contacts report status. Where a fieldbus is used, the interface can be offered with component redundancy. The list of protocols is wide: Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus and WirelessHART. Selecting the protocol early is important because the interface card and the wiring diagram depend on it. See also the AUMA Fieldbus page and the Industrial Ethernet page of this series for guidance on the protocol families.
Selection checklist for AC 01.2
- Actuator type and size the controls will be mounted on (SA .2 or SQ .2)
- Supply voltage, frequency and whether 24 V DC external supply is needed
- Control philosophy: parallel, analogue or fieldbus; protocol and redundancy requirement
- Required feedback signals and number of programmable output contacts
- Reversing contactors or thyristors, depending on duty and switching frequency
- Local or wall-bracket mounting and cable entry type
- Functional safety needs; for SIL functions use the SIL version of the controls
- Ambient temperature within -30 °C to +70 °C
Commissioning and maintenance of AC 01.2
Commissioning is menu-driven. Set the end positions and seating mode, define torque limits, assign the output contacts, select the behaviour on signal loss and test the local and remote command path. Save the parameter file with the order number so that a replacement unit can be configured quickly. Phase monitoring with automatic phase correction avoids damage from incorrect phase sequence during site reconnection. Periodic maintenance is largely based on the data stored in the controls: check start counters, torque curves and temperature logs for drifts before they become failures.
AC 01.2 in Oman and GCC installations
In the Gulf the controls face high ambient temperatures, dust and long cable runs. IP68 protection, KS corrosion class and the option of separate wall mounting address these factors. Water treatment and desalination plants appreciate the extended-operating-time function that avoids water hammer, while power and oil and gas sites value the diagnostic and fieldbus functions for remote supervision.
AC 01.2 compared with AM and the explosion-proof versions
| Controls | Role |
|---|---|
| AM | Simple controls with basic functions; parallel signals; few parameters set by sliding switches |
| AC 01.2 | Full functions, display, data logging, fieldbus, diagnostics |
| ACExC 01.2 | Explosion-proof version of the AC for hazardous areas |
| AC 01.2-SIL / ACExC 01.2-SIL | AC with additional SIL module for safety functions up to SIL 3 in redundant setups |
Information to send with an RFQ
- Part number: AC 01.2 and the actuator model it belongs to
- Supply voltage, frequency and phases
- Protocol and I/O requirements
- Mounting: on actuator or wall bracket (with cable distance)
- Ambient range and enclosure needs
- Quantity and delivery location
Site conditions in Oman for the AC 01.2
Valves and their accessories in Oman work in demanding conditions: high ambient temperatures, direct sun on outdoor pipe racks, dust, and corrosive coastal air at many oil, gas and water sites. When you specify the AC 01.2, confirm the pressure and temperature ratings, body and trim materials and any sour-service or hazardous-area requirements against the actual line data, and check that seals and soft parts suit the process medium and the full temperature range.
For reliable operation, plan access for maintenance, define which spare parts are kept on site, and record the configuration of each installed AC 01.2. Sending the complete process data sheet with your RFQ allows the selection to be checked before the order is placed.
Documents and quotation
Send the part number AC 01.2, the application and the quantity, and Seven Star LLC will confirm which official documents are available for your configuration. Please do not rely on a general description alone: the order data, wiring diagram number and explosion-protection marking of the delivered unit are what count for engineering and commissioning.
Seven Star LLC is an independent supplier in Muscat serving customers across Oman and the GCC. Quotations are prepared against your enquiry data and are confirmed individually.
Reviews (0)
How would you rate this product? Cancel reply
About brand
AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.
Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.
AUMA company profile
| Origin | Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers. |
|---|---|
| Headquarters | Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide. |
| Ownership | Privately held, owner-managed company: AUMA Riester GmbH & Co. KG |
| Torque and thrust range | Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA |
| Design principle | Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty |
Milestones
- 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
- Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
- 1974: AUMA Benelux, the first foreign subsidiary, is founded.
- Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.
AUMA actuator, controls and gearbox series
| Series | Type | Typical use |
|---|---|---|
| SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 | Multi-turn actuators, open-close duty | Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher |
| SAR 07.2 to SAR 30.1 | Multi-turn actuators, modulating duty | Control valves that receive a continuous position setpoint and many starts per hour |
| SAV, SARV, SQV, SQRV | Variable-speed actuators | Slow approach to the seat to limit water hammer, fast travel elsewhere |
| SQ 05.2 to SQ 14.2, SQR | Part-turn actuators | Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action |
| SAEx, SAREx, SQEx, PROFOX-MX, TIGRON | Explosion-proof actuators | Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions |
| AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL | Integral actuator controls | AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions |
| GS, GHE, SA + GS combination | Part-turn worm gearboxes | Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm |
| GK, GST, GHT, GP | Multi-turn gearboxes (bevel, spur, worm, planetary) | Offset or right-angle drives and very high multi-turn torque |
| LE, SVC/SVCR, PROFOX-L | Linear actuators and thrust units | Globe and control valves with a rising stem, up to 217 kN |
| PROFOX-M, PROFOX-Q | Compact smart actuators | Small valves where a full SA or SQ is oversized |
| SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN | Special versions | Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service |
| SIMA2 | Master station | Fieldbus network management for many actuators on one plant |
Where AUMA actuators are used
Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.
Ordering AUMA actuators and spare parts: what we need
For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.
Facts checked against AUMA product information and the company history published by AUMA, October 2026.
Browse AUMA products by category: Valve Actuator, Industrial Communications.
FAQ
Questions about the AUMA AC 01.2 AUMATIC Microprocessor Actuator
Answers from our engineering team on installation, compatibility and integration.
01What does AC 01.2 stand for?
AC is the AUMATIC microprocessor-based actuator control family, and 01.2 is the current design generation used with SA .2 and SQ .2 actuators.
02Which fieldbus protocols are supported?
The page lists Profibus DP/DP-V2, Profinet, Modbus RTU, Modbus TCP, HART, Foundation Fieldbus and WirelessHART, with component redundancy available for the fieldbus interface.
03What diagnostic data does the AC log?
It records time-stamped events, torque characteristics, temperature and vibration inside the actuator, the number of starts and the motor running times.
04Can the controls be mounted away from the actuator?
Yes. They can be mounted separately on a wall bracket, which helps with strong vibration, high ambient temperature at the valve or difficult access.
05What are the environmental ratings?
The key data lists IP68 enclosure protection, KS corrosion protection and an ambient range from -30 °C to +70 °C.