Brand:

AUMA SA 30.1 Multi-Turn Actuator

Description

Overview

AUMA SA 30.1 is an AUMA NORM multi-turn actuator for open-close duty with a tripping-torque window of 1,250 to 4,000 Nm and 12 output speeds from 4 to 180 rpm. SA 30.1 delivers 1,250 to 4,000 Nm through an F30 flange, accepts a rising stem up to 115 mm, and is fitted with a 500 mm handwheel. Weight is quoted between 190 and 260 kg depending on the speed range.

Seven Star LLC supplies AUMA products across Oman and the GCC and supplies the AUMA SA 30.1 with documentation and local support from Muscat.

Operating Principle

On the SA 30.1, motor turns are counted to fix the OPEN and CLOSED end positions, and torque switching releases at the set value up to 4,000 Nm in each direction. Duty is S2 – 15 min as standard, and the limit drops to 3,200 Nm at 125 rpm and 2,800 Nm at 180 rpm.

Engineering Design of the AUMA SA 30.1

The S2-15 min torque is 4,000 Nm up to 90 rpm, 3,200 Nm at 125 rpm and 2,800 Nm at 180 rpm; S2-30 min values are 2,800, 2,200 and 2,000 Nm. As with all SA 25.1 and larger sizes the standard enclosure is IP67 with IP68 as an option, and the motor terminals sit in a separate connection compartment rather than in the plug-in connector.

Key Features

Specifying the AUMA SA 30.1 comes down to these points:

  • Very heavy-duty multi-turn actuator for large sluice gates and valves.
  • The setting range runs from 1,250 to 4,000 Nm, so the largest setting is 3.2 times the smallest.
  • Rated S2 – 30 min torque of 2,800 Nm corresponds to 70 percent of the 4,000 Nm tripping maximum.
  • Weight-specific torque comes to roughly 15.4 to 21.1 Nm/kg.
  • An illustrative stroke of 80 turns takes about 150 seconds at 32 rpm.
  • Its closest relatives in the range are the SA 25.1 and the SA 35.1.
  • Request the separate AUMA dimension and electrical data sheets when planning the installation.

Selecting the AUMA SA 30.1

Compared with the SA 25.1, the AUMA SA 30.1 doubles the maximum torque, adds 20 mm of stem capacity (95 mm to 115 mm) and enlarges the handwheel from 400 mm to 500 mm, while the starts-per-hour limit remains at 40. The weight steps from 150 to 160 kg up to 190 kg for the lower speeds and 260 kg for the higher speeds, so the mounting structure and the valve bonnet or yoke must be checked for the extra load. The minimum tripping torque of 1,250 Nm means smaller valves should not be coupled to this size.

Typical partners are large wedge-gate valves, heavy globe valves in power-plant steam and feed-water systems, large penstocks and sluice gates at dams and intakes, and combinations with AUMA multi-turn gearboxes for very large butterfly and ball valves.

Large gates and valves rarely need to be operated quickly, and the slow end of the speed list is often the sensible choice for the AUMA SA 30.1. At 4 to 11 rpm the stroke of an 80-turn valve takes between 7 and 20 minutes, which protects the pipeline from water hammer and keeps motor heating low, while the full 4,000 Nm remains available. The only reason to move to the fast ratios is a short emergency closing time, and then the reduced torque at 125 and 180 rpm and the loss of self-locking above 90 rpm must be checked against the duty. Request the outline drawing for the chosen output drive early in the project, since the footprint of this size affects platform design, cable routing and the clearance needed for lifting equipment above the valve.

Sizing example for the AUMA SA 30.1

Take an illustrative gate that needs 2,400 Nm to break away and 1,300 Nm to run. A 25 percent allowance gives about 3,000 Nm, which falls inside the 1,250 to 4,000 Nm window of the AUMA SA 30.1. At 125 rpm 3,200 Nm is still available, but at 180 rpm only 2,800 Nm, so the 180 rpm ratio would fall short of this 3,000 Nm target. An 80-turn stroke at 11 rpm takes about 436 seconds and at 32 rpm about 150 seconds. These numbers are an illustrative calculation and not AUMA data.

Installation and Mounting of the AUMA SA 30.1

Weight is the decisive installation point: 190 kg for the lower speed group and 260 kg for the higher, which requires a crane and a structural check of the gate frame or valve yoke. The F30 flange takes a stem up to 115 mm and the 500 mm handwheel needs a wide clearance. Motor connection is made through terminals in a separate compartment, so allow enough cable space for the heavy-gauge cable of this motor size.

Industrial Applications

Examples in the region include main cooling-water inlet gates at thermal power stations, bulk-water reservoir isolation valves, port and terminal cargo-line valves, and large wastewater plant inlet gates. In the Sultanate’s interior, where large flood-protection and irrigation regulating gates are operated, the self-locking property up to 90 rpm lets the gate hold position without a brake.

In Oman and the GCC, Seven Star LLC also supplies the AUMA SA 10.2 multi-turn electric actuator, the AUMA MATIC AM/AC integral actuator controls and the AUMA SAEx explosion-proof actuator.

Neighbouring sizes and counterparts: AUMA SA 25.1 multi-turn actuator, AUMA SA 35.1 multi-turn actuator, AUMA SAR 30.1 modulating actuator and AUMA SAEx 30.1 explosion-proof actuator.

Technical Specifications

Data of the AUMA SA 30.1 from the AUMA technical data sheet for 3-phase AC motors.

Parameter Specification
Model AUMA SA 30.1
Trip torque range (S2 – 15 min) 1,250 to 4,000 Nm
S2 – 30 min limit 2,800 Nm
Higher-speed torque 3,200 Nm at 125 rpm and 2,800 Nm at 180 rpm (S2-15 min); 2,200 Nm and 2,000 Nm (S2-30 min)
Starts/h, max. 40
Output speed steps 4 to 180 rpm at 50 Hz, 4.8 to 216 rpm at 60 Hz, 12 steps
Mounting flange EN ISO 5210 F30; DIN 3210 G5
Rising-stem bore 115 mm
Manual wheel 500 mm
Unit weight 190 to 260 kg
Housing protection IP67 (IP68 optional)
Back-drive protection up to 90 rpm (50 Hz) / 108 rpm (60 Hz)

Setpoint guide for the SA 30.1 (illustrative calculation, not AUMA data)

Breakaway torque (Nm) Setpoint at +25 percent (Nm)
1,000 1,250
1,300 1,625
1,700 2,125
2,100 2,625
2,700 3,375
3,200 4,000

Stroking time for 80 turns at the SA 30.1 (illustrative calculation, not AUMA data)

rpm at 50 Hz rpm at 60 Hz Seconds for 80 turns at 50 Hz
4 4.8 1,200
5.6 6.7 857
8 9.6 600
11 13 436
16 19 300
22 26 218
32 38 150
45 54 107
63 75 76
90 108 53
125 150 38
180 216 27

Request a Quote for AUMA SA 30.1

Contact Seven Star LLC to buy the AUMA SA 30.1 in the 1,250 to 4,000 Nm class. Share the valve data, the F30 interface and the controls, and download the AUMA datasheet from this page.

Datasheets & Documents
  • PDF Datasheet AUMA SA 25.1 - SA 48.1 Technical Data Sheet (covers AUMA SA 30.1) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AUMA builds electric actuators for industrial valves, gates and dampers. The company was founded in 1964 near Stuttgart by Werner Riester and Rudolf Dinse, moved its headquarters to Müllheim in south-west Germany in the early 1970s, and still trades as the owner-managed AUMA Riester GmbH & Co. KG. Its actuators run isolation and control valves in water, power, oil and gas and process plants worldwide.

Seven Star LLC is an independent supplier listing AUMA multi-turn and part-turn actuators, actuator controls, gearboxes and spare parts for buyers in Oman and the GCC. We work from the nameplate data so that a replacement matches the installed actuator, controls and gearbox.

AUMA company profile

Origin Founded in 1964 by Werner Riester (engineering) and Rudolf Dinse (sales and finance); registered as Riester KG in Esslingen. Water and wastewater plants were the first customers.
Headquarters Müllheim, Baden-Württemberg, Germany (since the early 1970s). Production in Germany, with further plants in India, the USA and China, and around 30 sales and service companies worldwide.
Ownership Privately held, owner-managed company: AUMA Riester GmbH & Co. KG
Torque and thrust range Multi-turn, part-turn and linear actuators from 1.5 Nm to 675,000 Nm with gearboxes, and linear thrust up to 217 kN, as published by AUMA
Design principle Modular: actuator, integral controls and gearbox are combined to suit the valve, so one actuator size can serve open-close, modulating, fieldbus or explosion-proof duty

Milestones

  • 1964: Werner Riester and Rudolf Dinse found AUMA near Stuttgart; the first actuator range follows, with water and sewage plants as the first customers.
  • Early 1970s: Lack of space in Nellingen leads to the move to Müllheim in south-west Germany.
  • 1974: AUMA Benelux, the first foreign subsidiary, is founded.
  • Today: About 2,800 employees worldwide, around 850 of them in Müllheim, according to AUMA.

AUMA actuator, controls and gearbox series

Series Type Typical use
SA 07.2 to SA 16.2, SA 25.1 to SA 40.1 Multi-turn actuators, open-close duty Gate and globe valves, sluice gates and penstocks; SA 07.2 to 16.2 cover roughly 10 to 1,000 Nm, the .1 sizes go far higher
SAR 07.2 to SAR 30.1 Multi-turn actuators, modulating duty Control valves that receive a continuous position setpoint and many starts per hour
SAV, SARV, SQV, SQRV Variable-speed actuators Slow approach to the seat to limit water hammer, fast travel elsewhere
SQ 05.2 to SQ 14.2, SQR Part-turn actuators Ball, butterfly and plug valves and dampers, about 50 to 2,400 Nm; SQR for modulating duty; FQM fail-safe unit for spring-return action
SAEx, SAREx, SQEx, PROFOX-MX, TIGRON Explosion-proof actuators Hazardous areas in oil, gas and chemical plants, with ATEX and IECEx certified versions
AUMA MATIC AM, AUMATIC AC, ACExC 01.2, AMExC 01.1, AC 01.2-SIL Integral actuator controls AM for simple parallel wiring; AC for positioning, diagnostics and fieldbus (PROFIBUS DP, PROFINET, Modbus, FOUNDATION Fieldbus, HART depending on version); SIL version for safety functions
GS, GHE, SA + GS combination Part-turn worm gearboxes Large butterfly and ball valves, from GS 63.3 up to GS 630.3 at 675,000 Nm
GK, GST, GHT, GP Multi-turn gearboxes (bevel, spur, worm, planetary) Offset or right-angle drives and very high multi-turn torque
LE, SVC/SVCR, PROFOX-L Linear actuators and thrust units Globe and control valves with a rising stem, up to 217 kN
PROFOX-M, PROFOX-Q Compact smart actuators Small valves where a full SA or SQ is oversized
SA-UW, SGM/SGMR, SVM/SVMR, SAN/SARN Special versions Submerged valves, seawater-exposed ship and offshore duty, nuclear plant service
SIMA2 Master station Fieldbus network management for many actuators on one plant

Where AUMA actuators are used

Water transmission and treatment is the largest use: pipeline isolation valves, pumping stations, desalination plants and sluice gates. AUMA actuators also run valves in power plant steam, feedwater and cooling systems, pipelines and tank farms, refineries and chemical plants, and on ships and offshore platforms. In the Gulf, check the ambient temperature rating, since actuators in direct sun can exceed 50 °C, and specify the enclosure protection for sand and humidity.

Ordering AUMA actuators and spare parts: what we need

For a replacement, send photos of the actuator, motor and controls nameplates: type designation, commission or order number, serial number and wiring diagram number. AUMA identifies the original build from the commission number. For a new actuator, add the valve type, required torque or thrust at the worst case, number of turns or swing angle, operating time, mounting flange to ISO 5210 or ISO 5211, stem or shaft dimensions, duty (open-close or modulating), supply voltage and frequency, control signals or fieldbus, and the hazardous-area marking required on site.

Facts checked against AUMA product information and the company history published by AUMA, October 2026.

FAQ

Questions about the AUMA SA 30.1 Multi-Turn Actuator

Answers from our engineering team on installation, compatibility and integration.

01What is the torque range of the AUMA SA 30.1?
The tripping torque of the AUMA SA 30.1 is adjustable between 1,250 and 4,000 Nm in S2 - 15 min duty, and the S2 - 30 min maximum is 2,800 Nm. Torque is reduced at the highest speeds: 3,200 Nm at 125 rpm and 2,800 Nm at 180 rpm (S2-15 min); 2,200 Nm and 2,000 Nm (S2-30 min).
02Which output speeds and starts per hour does the AUMA SA 30.1 offer?
The AUMA SA 30.1 offers 12 output speeds from 4 to 180 rpm at 50 Hz and up to 40 starts per hour, and it is self-locking up to 90 rpm (50 Hz) / 108 rpm (60 Hz). An illustrative valve needing 80 turns takes about 150 seconds at 32 rpm.
03Which valve flange and stem size does the AUMA SA 30.1 fit?
The AUMA SA 30.1 has an EN ISO 5210 F30 flange (DIN 3210 G5 optional) and takes a rising stem up to 115 mm. Special output drives AF, AK, AG, B3D, ED and DD are offered, while IB1 and IB3 interfaces are on request for sizes above SA 25.1.
04When should I choose the AUMA SA 30.1 instead of a neighbouring size?
Select the AUMA SA 30.1 for valve torques of about 1,250 to 4,000 Nm. If the requirement exceeds 4,000 Nm the next size is the SA 35.1 (2,500 to 8,000 Nm, F35), and for loads under about 2,000 Nm the SA 25.1 is lighter and more closely matched.
05Is Seven Star LLC a trusted supplier for AUMA products?
Yes. Seven Star LLC supplies genuine AUMA products across Oman and the GCC. The AUMA SA 30.1 is supplied as genuine AUMA product with documentation and regional technical support from our Muscat team.