Honeywell SmartLine GWR Guided Wave Radar Level Transmitter
Description
SmartLine GWR guided wave radar level transmitter (SLG700)
The Honeywell SmartLine GWR is the guided wave radar level transmitter in the SmartLine family, sold as the SLG 700 series. It sends nanosecond radar pulses down a rod, wire or coaxial probe and measures how long the reflection from the liquid surface takes to return (time domain reflectometry). The result is level, volume or interface level on a two-wire, loop-powered 4 to 20 mA signal with HART or FOUNDATION Fieldbus. Seven Star LLC supplies SmartLine GWR transmitters in Oman and the GCC as an independent supplier in Muscat.
The series has two versions: SLG720 for standard pressure and temperature, and SLG726 for high pressure and temperature up to 400 bar and 450 °C, including a saturated-steam compensated version for boiler drums.
SmartLine GWR technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Honeywell / SmartLine GWR (SLG 700 series: SLG720, SLG726) |
| Measuring principle | Time domain reflectometry (guided wave radar) |
| Measured media and variables | Liquids; level, volume and interface |
| Maximum measuring range | 50 m (164 ft); 35 m (115 ft) with FEP-coated probe |
| Accuracy | Rod and coax ±3 mm; wire ±0.03 % of range or ±3 mm, whichever is greater |
| Repeatability and resolution | ±1 mm repeatability, 1 mm resolution |
| Process temperature | SLG720 -40 to 200 °C; SLG726 -60 to 450 °C |
| Process pressure (MAWP) | SLG720 up to 40 bar (580 psi); SLG726 up to 400 bar (5800 psi); vacuum to -1 bar |
| Minimum dielectric constant | 1.4 (1.2 with the optional low-DC algorithm) |
| Probes | Rod 0.4 to 6.3 m; wire 1.0 to 50 m; coax 0.4 to 6.3 m; 316L, C-276 (UNS N10276) or FEP-coated (SLG720) |
| Output | 4 to 20 mA with HART 7, or FOUNDATION Fieldbus (ITK 6.0.1) |
| Supply voltage | HART 14 to 42 Vdc (load 0 to 1284 ohm); Fieldbus 9 to 32 Vdc (IS limited to 30 Vdc) |
| Housing | Powder-coated low-copper aluminium, stainless steel optional; NEMA 4X, IP66, IP67; weight about 3.2 kg |
| Display | 128 x 64 pixel graphics LCD with three-button keypad (optional) |
| Functional safety and other | IEC 61508 SIL 2/3 option; WHG overfill protection certificate |
How SmartLine GWR measures level and interface
A pulse travels along the probe until it meets a change in dielectric constant, which is the product surface. Part of the energy is reflected, and the electronics convert the transit time into distance and then into level, volume or ullage. The method does not depend on density, conductivity or temperature, but the product needs a dielectric constant of at least 1.4.
For two-liquid interface, the transmitter reports both the surface and the interface. The datasheet limits are an upper-medium dielectric constant of at most 9, a lower-medium dielectric constant of at least 10, a difference of at least 8, and an upper layer of at least 7 cm; the measuring accuracy of both is ±3 mm. In high-pressure boilers the SLG726 steam-compensated version uses a reference measurement of the steam dielectric constant, because uncompensated error is about 1 % at 172 °C and 5 % at 250 °C.
SmartLine GWR probes, blocking distances and mounting
Rod probes suit short, clean spans up to 6.3 m, wire probes go to 50 m and tolerate low headroom, and coaxial probes give the strongest signal for low-dielectric products and turbulent tanks. Blocking distances depend on probe and product: for a rod or wire probe in water the minimum upper blocking distance is 9 cm, in oil 7 cm; coax is 5 cm in both. Nozzles should preferably be 150 mm (6 in) wide, at least 50 mm (2 in), and a taller nozzle adds to the upper blocking distance.
For bypass chambers and stilling wells, Honeywell recommends 3 or 4 inch pipe for rod probes and 4 inch for wire probes, with the probe 25 mm (1 in) above the bottom and a centering disk for rigid probes longer than 1 m. The SLG 700 can also be ordered with remote electronics on a 3 m cable.
SmartLine GWR selection and ordering checklist
- SLG720 or SLG726, set by the maximum working pressure (40 bar or 400 bar) and temperature (200 °C or 450 °C).
- Probe type, length and material: rod, wire or coax, in 316L or C-276, with optional FEP coating on SLG720.
- Process connection: NPT (from 3/4 inch), BSP, or flange from DN40 / 1.5 inch, and the O-ring or metal seal material for the temperature.
- Output and housing: HART or FOUNDATION Fieldbus, aluminium or stainless housing, display, remote mounting.
- Dielectric constant of the product, tank dimensions, nozzle height and interface or steam duty.
- Hazardous-area approval, SIL certification and overfill protection requirement.
Installing and commissioning SmartLine GWR
Keep the probe at least 400 mm from tank walls and obstacles for reference accuracy, avoid nozzles wider than 200 mm for single-lead probes, and fit a metal flange over 2 inch / DN50 or a metal plate when the vessel is plastic. Wiring is polarity insensitive, and the electronics are in a dual-compartment housing with replaceable modules. Honeywell offers an online SmartLine Application and Validation Tool so that the tank data can be validated and the transmitter delivered pre-configured, which reduces commissioning time.
Echo curves can be viewed on the local display as stem plots or through the DTM-based field service tool, FDM and Experion PKS. When the probe sits in a nozzle, Honeywell requires a field background measurement to reach the stated blocking distance and upper-zone accuracy.
Typical SmartLine GWR applications in Oman and the GCC
Typical uses are separators, scrubbers and knock-out drums in oil and gas, hydrocarbon storage and day tanks, condensate and chemical tanks, feedwater and deaerator vessels, and boiler drums where the SLG726 handles high pressure and steam. Hot desert conditions and process temperatures are covered by the -40 to 85 °C ambient rating and the metallic-seal options for high temperature.
SLG720 and SLG726 compared
| Item | SLG720 | SLG726 |
|---|---|---|
| Process temperature | -40 to 200 °C | -60 to 450 °C |
| Maximum pressure | 40 bar (580 psi) | 400 bar (5800 psi) |
| Wetted materials | PTFE, duplex 2205 and 316L or C-276, FEP option | 316L, glass, PEEK, gold, Viton and aluminium parts |
| Special function | FEP-coated probe for build-up | Saturated-steam compensation |
Information to send with a SmartLine GWR RFQ
- Tag list and the version (SLG720 or SLG726) if already known.
- Product, dielectric constant, density, pressure and temperature range.
- Tank type, height, nozzle size and any bypass chamber dimensions.
- Output (HART or Fieldbus), approvals and SIL needs.
- Quantity and delivery location.
Documents and quotation
The Honeywell SLG 700 guided wave radar specification (34-SL-03-03) is attached on this page. It contains the probe tables, blocking distances, approvals and dimensional drawings. Send your application data and we will quote the right SmartLine GWR version.
Seven Star LLC is an independent supplier in Muscat; availability is confirmed per order.
Other Models in the Honeywell Smartline Level Range
Seven Star LLC supplies models from the Honeywell Smartline Level range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell SmartLine GWR Guided Wave Radar Level Transmitter | Level Instrumentation | You are viewing this model |
| Honeywell SmartLine NCR 80 GHz Radar Level Transmitter | Level Instrumentation | View details |
Datasheets & Documents
- Datasheet Honeywell SmartLine GWR (SLG 700) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell SmartLine GWR Guided Wave Radar Level
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between SLG720 and SLG726?
SLG720 handles up to 40 bar and 200 °C. SLG726 handles up to 400 bar and 450 °C and has a saturated-steam compensated option for boiler drums.
02What is the maximum range of the SmartLine GWR?
50 m with a wire probe, or 35 m with an FEP-coated probe. Rod and coax probes reach 6.3 m.
03How accurate is the SmartLine GWR?
±3 mm for rod and coax probes, and ±0.03 % of range or ±3 mm for wire probes, with ±1 mm repeatability.
04Can the SmartLine GWR measure interface?
Yes, with an upper layer of at least 7 cm, an upper dielectric constant up to 9, a lower constant of at least 10 and a difference of at least 8.
05What outputs does the SmartLine GWR provide?
Two-wire 4 to 20 mA with HART 7, or FOUNDATION Fieldbus. A SIL 2/3 option and WHG overfill protection certificate are listed.