- Automation & ControlView all 3,015 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V DC, 4 c/o
Description
ABB 1SVR405613R4000 CR-M012DC4 for 12 V DC systems
Most CR-M relays on the market are 24 V devices, but 12 V DC remains common in battery-backed telecom shelters, vehicle-mounted equipment, solar installations and small engine controllers. ABB 1SVR405613R4000, the CR-M012DC4, is the 12 V DC coil version of the four-contact relay. Its coil makes at 9.6 V and is rated up to 13.2 V DC at 55 degrees C, so a battery that sags under load still keeps the relay pulled in.
All four changeover contacts are silver-nickel, rated 6 A at 250 V, so one small relay can distribute a 12 V command into four separate circuits that may even carry different voltages: mains on one contact, 24 V DC on another and a dry signal on the third.
Highlights of 1SVR405613R4000
- 12 V DC coil, 0.9 W, 160 ohm at 20 degrees C.
- Coil pull-in at 9.6 V DC, maximum 13.2 V DC.
- Four c/o AgNi contacts at 6 A.
- No LED, mechanical status indicator and blue test button.
- Inrush rating 12 A, switching power 1500 VA in AC1.
- Rated insulation voltage 250 V AC.
1SVR405613R4000 data table
| Order code | 1SVR405613R4000 |
|---|---|
| Type | CR-M012DC4 |
| Control voltage | 12 V DC |
| Make voltage | 9.6 V DC |
| Maximum voltage (55 C) | 13.2 V DC |
| Coil resistance | 160 ohm +/-10 percent |
| Coil power | 0.9 W |
| Contacts | 4 c/o AgNi |
| Thermal current | 6 A |
| AC15, 230 V | 1 A |
| DC13, 24 V | 2 A |
| Making current | 12 A |
| Mechanical life | more than 20 million cycles |
| Response / release | typ. 13 ms / typ. 3 ms |
| Operating temperature | -40 to +70 C |
| Storage temperature | -40 to +85 C |
| Rated impulse withstand coil/contacts | 2.5 kV |
| Weight | 35 g |
Where CR-M012DC4 sits in the 4 c/o family
The 160 ohm winding is the lowest in the family: the 24 V DC version has 640 ohm, the 48 V version 2600 ohm and the 220 V version 54000 ohm. Because the power stays 0.9 W, the coil current at 12 V is about 75 mA, roughly double the current of the 24 V version. Wire size and fuse size for the control supply should be checked when many CR-M012DC4 relays share one battery feed. Counting ten relays on one 12 V branch, the coils alone draw about 0.75 A, which is easy to forget when the branch is fused for the logic only. The other differences are the AC-coil release threshold of 0.2 times Us against 0.1 for DC types, and the +70 degrees C ambient limit that DC coils reach where AC coils stop at +55 degrees C.
Use in Omani installations
Remote telemetry cabinets that run from solar panels and batteries, wellhead monitoring and cathodic-protection monitoring stations are the sort of places where a 12 V coil matters. The relay picks up reliably on a battery that sags during cranking or a cloudy day and lets one microcontroller output drive several circuits. In vehicles and portable generators used at construction sites, the relay is plugged into a socket so it can be changed in seconds. The same logic applies to standby diesel generator panels, where 12 V cranking and control circuits are normal and a failed relay has to be replaced by the site electrician with nothing more than a screwdriver and a spare from the cabinet.
Mounting and wiring
Choose a CR-M4 socket (for 2 or 4 c/o contacts), connect 12 V DC to A1 and A2 and the loads to the numbered contacts. Keep wires short in battery systems to limit voltage drop, because the coil must see at least 9.6 V. Add a CR-P/M 22 diode module, which is listed for 6 to 230 V DC with A1 positive and A2 negative, or a similar protective module when a transistor output drives the relay, so that the switch-off voltage spike does not reach the driver. If the supply is a switched-mode charger, measure the voltage at the relay socket under full load and during engine cranking as well, because the coil must still see 9.6 V at its lowest point. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Maintenance
Test the coil resistance with the relay removed; about 160 ohm, within plus or minus 10 percent, indicates a healthy winding. Replace a relay whose contacts show pitting or whose test button no longer locks. Spare relays can be stored between -40 and +85 degrees C, and they ship in packing units of ten pieces from the manufacturer. The four-contact CR-M relays also carry a Lloyds Register mention in the approvals list of the datasheet, in addition to UL 508, CAN/CSA, VDE, GOST, CCC and CE marking, which is useful information for marine and offshore panel builders who must show type approval for their components.
Quick answers about 1SVR405613R4000
What coil voltage does 1SVR405613R4000 use? 12 V DC; it pulls in at 9.6 V DC and tolerates up to 13.2 V DC at 55 degrees C.
How much current does the coil of 1SVR405613R4000 draw? The coil power is 0.9 W with a resistance of 160 ohm, so about 75 mA at 12 V.
How many contacts does 1SVR405613R4000 have? Four c/o contacts with 6 A thermal current and 250 V rated voltage.
Is there a 24 V version of 1SVR405613R4000? Yes; the 24 V DC equivalent is the CR-M024DC4, with the same contacts and housing.
Does 1SVR405613R4000 need a socket? Yes; use a CR-M4 series socket for four contacts.
Documents and quotation
See the data sheet for coil tables and diagrams. To order 1SVR405613R4000, send an RFQ with the quantity and delivery location.
Typical Questions From Maintenance Teams
Maintenance engineers replacing a ABB 1SVR405613R4000 usually ask whether the new unit is a direct fit, whether settings can be copied from the old one, and whether any accessories must be ordered separately. The answer depends on the exact order code and the generation of the installed automation accessories, so the nameplate details are the best starting point. Send them with your request and we will check the match, point out any differences in connections or options, and list the parts needed so that the job can be finished in one visit.
Other Models in the Abb Cr M Range
Seven Star LLC supplies models from the Abb Cr M range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SVR405613R3000 CR-M230AC4 Interface Relay 230 V AC, 4 c/o | Automation Accessories | View details |
| ABB 1SVR405618R1000 CR-M024DC4G Gold-Contact Interface Relay 24 V DC | Automation Accessories | View details |
| ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V DC, 4 c/o | Automation Accessories | You are viewing this model |
| ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24 V DC, 2 c/o, LED | Automation Accessories | View details |
| ABB 1SVR405613R0000 CR-M024AC4 Interface Relay 24 V AC, 4 c/o | Automation Accessories | View details |
| ABB 1SVR405614R1100 CR-M024DC4LD Relay 24 V DC, LED and Diode | Automation Accessories | View details |
Datasheets & Documents
- Datasheet ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V DC, 4 c/o Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V
Answers from our engineering team on installation, compatibility and integration.
01What coil voltage does 1SVR405613R4000 use?
12 V DC; it pulls in at 9.6 V DC and tolerates up to 13.2 V DC at 55 degrees C.
02How much current does the coil of 1SVR405613R4000 draw?
The coil power is 0.9 W with a resistance of 160 ohm, so about 75 mA at 12 V.
03How many contacts does 1SVR405613R4000 have?
Four c/o contacts with 6 A thermal current and 250 V rated voltage.
04Is there a 24 V version of 1SVR405613R4000?
Yes; the 24 V DC equivalent is the CR-M024DC4, with the same contacts and housing.
05Does 1SVR405613R4000 need a socket?
Yes; use a CR-M4 series socket for four contacts.


















Reviews