Brand: ABB
ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24 V DC, 2 c/o, LED
Description
ABB 1SVR405611R1100 CR-M024DC2L at a glance
ABB 1SVR405611R1100 is the order code of the CR-M024DC2L, a pluggable miniature interface relay with a 24 V DC coil, two changeover (c/o, SPDT) output contacts and a built-in LED that shows when the coil is energised. It belongs to the CR-M range that ABB designed for the border between electronic control and the field: a PLC or DCS output energises a small coil, and the relay then switches a heavier or galvanically separate circuit on its contacts.
What makes the 1SVR405611R1100 attractive for 24 V control cabinets is the combination of the two-contact layout and the highest contact rating in the CR-M family, 12 A at 250 V. The three- and four-contact versions trade that current down to 10 A and 6 A to fit more contacts into the same housing. If your loop only needs two independent contacts, for example one to a solenoid and one to a feedback input, this is the variant that keeps the thermal headroom.
The relay does not carry its own protective circuit, so the datasheet describes it as overload-proof against short-term current and voltage peaks rather than as a protected unit; surge suppression can be added by plugging in a function module.
Key features of the 1SVR405611R1100
- Coil: 24 V DC, 0.9 W, 640 ohm at 20 degrees C, tolerance plus or minus 10 percent.
- Outputs: 2 c/o contacts, silver-nickel, thermal current 12 A, rated operational voltage 250 V.
- LED coil indication, in addition to the mechanical status indicator on the housing.
- Integrated test button for manual actuation and locking of the contacts; blue for DC types, removable if it is not wanted.
- Cadmium-free contact material and a plug-in design that allows quick exchange on its socket.
- Width on the socket of 27 mm, which keeps the relay row compact on a DIN rail.
1SVR405611R1100 technical specifications
| Order code | 1SVR405611R1100 |
|---|---|
| Type designation | CR-M024DC2L |
| Rated control supply voltage Us | 24 V DC |
| Coil make voltage (20 C) | 19.2 V DC |
| Maximum coil voltage (55 C) | 26.4 V DC |
| Break voltage | 0.1 x Us or higher |
| Rated coil power / resistance | 0.9 W / 640 ohm |
| Outputs | 2 c/o (SPDT), AgNi |
| Rated thermal current Ith | 12 A |
| Resistive AC12, 230 V | 12 A |
| Inductive AC15, 230 V / 120 V | 1.5 A / 3 A |
| DC12, 24 V / DC13, 24 V | 12 A / 2.5 A |
| Maximum making (inrush) current | 24 A |
| Maximum breaking power AC1 | 3000 VA |
| Contact resistance | 100 milliohm or less |
| Mechanical life | more than 20 million cycles |
| Electrical life AC1 (12 A, 250 V) | more than 100000 cycles |
| Response / release time | typ. 13 ms / typ. 3 ms (DC) |
| Dimensions mounted (W x H x D) | 21.2 x 27.5 x 35.6 mm |
| Weight | 35 g |
| Degree of protection | IP40 |
| Operating temperature (DC coil) | -40 to +70 C |
| Packing unit | 10 pieces |
How 1SVR405611R1100 differs from other CR-M variants
The CR-M family is built from one housing and a grid of coil voltages, contact counts and options, so the useful question is which digit or letter changes what. In CR-M024DC2L the “2” after the voltage means two c/o contacts at 12 A, where a “3” gives three contacts at 10 A and a “4” gives four contacts at 6 A. The inrush current follows the same order: 24 A for two contacts, 20 A for three and 12 A for four. The trailing “L” is the LED; the plain CR-M024DC2 omits it and the CR-M024DC4LD adds a free-wheeling diode as well.
Voltage is the second axis. DC coils from 12 V to 220 V draw 0.9 W, whereas AC coils from 24 V to 230 V draw 1.6 VA and have a higher drop-out threshold of 0.2 x Us instead of 0.1 x Us. For 1SVR405611R1100 the 24 V DC coil operates between 19.2 V and 26.4 V DC, so a supply that sags below about 19 V is outside the specified pull-in range.
Where the 1SVR405611R1100 is used in Oman and the GCC
A 24 V DC relay with two 12 A contacts is a staple of skid-mounted and cabinet-based control. In oil and gas installations around Muscat and Sohar it often sits between a safety-related PLC output and a motor starter coil or a field solenoid, giving galvanic isolation without a bulky contactor. Utilities use the same pattern for breaker-trip repeating and alarm duplication in 24 V DC substation panels, while water and wastewater plants place the relay behind remote I/O to start dosing pumps and open actuated valves.
In manufacturing, the LED helps maintenance staff find a stuck output quickly on a crowded rail: if the lamp is lit but the load is dead, the fault is downstream of the contact rather than in the PLC channel.
Selection and compatibility notes for 1SVR405611R1100
The relay plugs into the CR-M socket family and needs one to operate. For two c/o contacts the matching screw-type sockets are the logical CR-M2LS (1SVR405651R1100), the spring-clamp CR-M2LC (1SVR405651R1200) and the standard CR-M2SS (1SVR405651R1000). The four-contact sockets CR-M4LS and CR-M4SS also accept two-contact relays. Plastic and metal holders, a jumper bar for screw sockets and the pluggable function modules complete the system.
Check three points before ordering: coil voltage versus your control supply, the contact load including its inductive character, and the ambient temperature. The DC-coil version is rated for -40 to +70 degrees C. Remember that the datasheet limits DC inductive switching to 2.5 A at 24 V and only 0.1 A at 250 V DC, so switching DC loads through this relay needs a derating check against the load-limit curves in the datasheet.
Installing and commissioning the 1SVR405611R1100
Fit the socket on a 35 mm DIN rail, wire the coil to A1 and A2 and the loads to the 11-12/14 and 41-42/44 terminals, then push the relay in until it seats. The test button lets you lock the contacts closed for loop testing without a control signal; release it before handing the cabinet over. Because the housing is rated IP40 and the relay may be mounted in any position, orientation inside the panel is a free choice.
A short functional check is enough: apply 24 V DC to the coil, confirm that the LED lights, listen for the click, and measure continuity on the 14 and 44 terminals. When switching inductive DC loads add a free-wheeling element across the load or use a diode module so the contacts are not degraded by switch-off arcs.
Maintenance and replacement of 1SVR405611R1100
Mechanical endurance is above 20 million cycles, but the contact set ages with load: at 12 A and 250 V resistive the electrical life is above 100000 cycles. Plan a replacement interval from the switching counts of the output channel and swap the relay as a unit; the socket stays wired. Look for blackened contact windows, a sticky test button or an LED that no longer lights with the coil energised. Storage is allowed from -40 to +85 degrees C, so spares can be kept in a normal store room.
Other CR-M relays that are often requested alongside 1SVR405611R1100 include the 3 c/o and 4 c/o types in the same coil voltage and the matching sockets and diode or LED modules. State the coil voltage, the contact count and whether an LED is required when you send the request. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; part numbers on this page are quoted from the manufacturer documentation for identification.
Quick answers about 1SVR405611R1100
What does the L in CR-M024DC2L mean? The L indicates the built-in LED that shows the coil is energised; the CR-M024DC2 without the L has the same coil and contacts but no LED.
How many amps can the contacts of 1SVR405611R1100 switch? Each of the two c/o contacts has a rated thermal current of 12 A at 250 V, with a resistive AC12 rating of 12 A at 230 V and 12 A at 24 V DC resistive.
Does 1SVR405611R1100 include a socket? No. The relay is a plug-in part, so a CR-M socket must be ordered separately; for two contacts the CR-M2LS, CR-M2LC or CR-M2SS types are suitable.
What coil voltage range applies to the CR-M024DC2L? The 24 V DC coil makes at 19.2 V DC and tolerates up to 26.4 V DC at 55 degrees C, with a break voltage of at least 0.1 times the rated voltage.
Can 1SVR405611R1100 be used on 24 V AC? No. It is a DC-coil type; for 24 V AC control the matching AC-coil versions with a 1.6 VA coil must be selected instead.
Documents and quotation
The manufacturer data sheet for the CR-M range is available for download from this page and covers the ratings, the coil table and the dimension drawings referred to above. To request a quotation for ABB 1SVR405611R1100, send an RFQ with the part number, the quantity and the delivery location in Oman or the GCC. If you need the matching socket or a function module at the same time, list those part numbers in the same message.
Other Models in the Abb Cr M Range
Seven Star LLC supplies models from the Abb Cr M range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SVR405613R3000 CR-M230AC4 Interface Relay 230 V AC, 4 c/o | Automation Accessories | View details |
| ABB 1SVR405618R1000 CR-M024DC4G Gold-Contact Interface Relay 24 V DC | Automation Accessories | View details |
| ABB 1SVR405613R4000 CR-M012DC4 Interface Relay 12 V DC, 4 c/o | Automation Accessories | View details |
| ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24 V DC, 2 c/o, LED | Automation Accessories | You are viewing this model |
| ABB 1SVR405613R0000 CR-M024AC4 Interface Relay 24 V AC, 4 c/o | Automation Accessories | View details |
| ABB 1SVR405614R1100 CR-M024DC4LD Relay 24 V DC, LED and Diode | Automation Accessories | View details |
Datasheets & Documents
- Datasheet ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24 V DC, 2 c/o, LED Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SVR405611R1100 CR-M024DC2L Interface Relay 24
Answers from our engineering team on installation, compatibility and integration.
01What does the L in CR-M024DC2L mean?
The L indicates the built-in LED that shows the coil is energised; the CR-M024DC2 without the L has the same coil and contacts but no LED.
02How many amps can the contacts of 1SVR405611R1100 switch?
Each of the two c/o contacts has a rated thermal current of 12 A at 250 V, with a resistive AC12 rating of 12 A at 230 V and 12 A at 24 V DC resistive.
03Does 1SVR405611R1100 include a socket?
No. The relay is a plug-in part, so a CR-M socket must be ordered separately; for two contacts the CR-M2LS, CR-M2LC or CR-M2SS types are suitable.
04What coil voltage range applies to the CR-M024DC2L?
The 24 V DC coil makes at 19.2 V DC and tolerates up to 26.4 V DC at 55 degrees C, with a break voltage of at least 0.1 times the rated voltage.
05Can 1SVR405611R1100 be used on 24 V AC?
No. It is a DC-coil type; for 24 V AC control the matching AC-coil versions with a 1.6 VA coil must be selected instead.