- Automation & ControlView all 3,043 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: ABB
ABB 1SVR405606R1000 CR-P024DC2G Gold-Contact Relay 24 V DC, 2 c/o
Description
ABB 1SVR405606R1000: gold-contact version of the 24 V DC CR-P relay
ABB 1SVR405606R1000 is the CR-P024DC2G. The suffix G marks the optional gold contacts that ABB lists for the 2 c/o CR-P relays. Everything else is the familiar CR-P body: a 24 V DC coil, two changeover contacts rated 8 A at 250 V and a slim 15.5 mm footprint on the socket. The gold version appears as a separate group in the order data, “2 c/o (SPDT) with gold contacts: 250 V, 8 A”, with four coil options: 24 V DC, 24 V AC, 110 V AC and 230 V AC.
Gold contacts are chosen when a relay is going to switch weak signals, such as the 4-20 mA inputs of analog cards, because gold resists oxide film formation. It is useful on interfaces between sensors and the PLC.
Inside the gold group the 1SVR405606R1000 is the only DC type, which makes it the natural relay for a 24 V DC PLC output chain. Its coil data are the same as the standard CR-P024DC2: 24 V DC, 16.8 V DC to pull in and a break voltage of 0.1 times Us.
Points to note about 1SVR405606R1000
- Gold contacts, 2 c/o, 8 A rated, 250 V.
- 24 V DC coil, 0.4 to 0.48 W, 1440 ohm.
- Body 12.7 x 29 x 15.7 mm, weight 14 g.
- IP67 relay body, plug-in design.
- DC coils operate from -40 to +85 degrees C.
1SVR405606R1000 datasheet figures
| Order code | 1SVR405606R1000 |
|---|---|
| Type | CR-P024DC2G |
| Contacts | 2 c/o, gold version |
| Coil voltage | 24 V DC |
| Make voltage | 16.8 V DC |
| Coil resistance | 1440 ohm |
| Coil power | 0.4-0.48 W |
| Thermal current | 8 A |
| Rated operational voltage | 250 V |
| Maximum switching voltage | 300 V DC / 440 V AC |
| Response / release time | typ. 7 ms / typ. 3 ms |
| Mechanical life | more than 30 million cycles |
| Rated insulation voltage | 400 V AC |
| Impulse withstand coil/contacts | 5 kV |
| Clearance coil to contacts | 10 mm or more |
| Degree of protection | IP67 |
| Weight | 14 g |
| Operating temperature | -40 to +85 C |
Gold versus standard contacts in CR-P
The CR-P gold group exists only in the 2 c/o layout: CR-P024DC2G, CR-P024AC2G, CR-P110AC2G and CR-P230AC2G. Standard 2 c/o relays like CR-P024DC2 use AgNi contacts and cover loads from 5 V and 5 mA. The 8 A thermal current and the 250 V rating are shared by both versions, and the order data lists the gold relays alongside the standard ones in the same 8 A class. When your circuit carries only milliamps, prefer CR-P024DC2G; when it also carries amps on a regular basis, the standard AgNi version is the safer choice, and the two should not be mixed on the same channel over time.
Typical roles
Instrument marshalling, PLC input multiplexing, gas detector relays reporting to safety PLCs and signal isolation between DCS cards and field analyzers are the natural roles. Oil and gas and petrochemical sites in the region often specify gold-contact relays on signal paths that run for years without maintenance. A typical case is a hundred-channel marshalling cabinet at a gas-processing plant, where every relay between a field transmitter and an I/O card is fitted once and expected to stay untouched until the next turnaround. Another is the interface between a fire-and-gas detector and a shutdown logic solver, where an intermittent contact would show up as a spurious alarm that costs the operator a trip investigation.
Selection and fitting
Because the datasheet gives the same mechanical and isolation data for gold and standard 2 c/o relays, panel layout does not change: the pitch is 15.5 mm, mechanical life exceeds 30 million cycles, and the clearance and creepage between coil and contacts are 10 mm or more. Contacts between the two c/o circuits are rated for 2.5 kV impulse and open contacts for 1 kV. Approvals listed for the CR-P range are UL 508, CAN/CSA C22.2 No. 14, VDE, GOST, CCC and RMRS with CE marking, and the range is cadmium-free. The relay is supplied in packs of ten.
Choose a CR-P socket and, if desired, the diode or LED modules listed in the datasheet. Keep the relay for signal duty only. Coil: makes at 16.8 V DC; the relay body is sealed. Impulse withstand of 5 kV across coil and contacts and 400 V AC insulation voltage allow safe separation of 24 V DC control from mains-level signals on the other side.
Modules, limits and care
For the 24 V DC coil of 1SVR405606R1000 the modules of interest are the reverse-polarity diode CR-P/M 22 (6-230 V DC, 1SVR405651R0000), the diode-and-LED modules CR-P/M 42 in red (1SVR405652R0000) and CR-P/M 42V in green (1SVR405652R1000) for 6-24 V DC, and the varistor-and-LED modules CR-P/M 62C and 62CV for 6-24 V AC/DC. The maximum operating frequency is 600 cycles per hour at rated AC1 load and 72000 per hour without load, and the standard contacts carry a minimum switching rating of 5 V and 5 mA, the figure to compare with your analog signal levels before deciding that gold is needed at all.
Do not reuse a relay that has switched power for signal duty. Handle by the body, not the pins. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SVR405606R1000
What does the G in CR-P024DC2G stand for? Gold contacts, an optional contact finish for the 2 c/o CR-P relays.
What coil does 1SVR405606R1000 have? 24 V DC with 1440 ohm and 0.4 to 0.48 W.
What is the contact rating of 1SVR405606R1000? 8 A thermal current at 250 V on each of the two c/o contacts.
Which other gold CR-P versions exist? CR-P024AC2G, CR-P110AC2G and CR-P230AC2G.
Is 1SVR405606R1000 sealed? The datasheet states a degree of protection of IP67 for the relay body.
Documents and quotation
The datasheet for the CR-P family is available on this page. For a quotation on 1SVR405606R1000, send an RFQ listing the part number, quantity and delivery destination.
Other Models in the Abb Cr P Range
Seven Star LLC supplies models from the Abb Cr P range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SVR405601R1000 CR-P024DC2 Pluggable Relay 24 V DC, 2 c/o 8 A | Automation Accessories | View details |
| ABB 1SVR405600R0000 CR-P024AC1 Pluggable Relay 24 V AC, 1 c/o 16 A | Automation Accessories | View details |
| ABB 1SVR405606R1000 CR-P024DC2G Gold-Contact Relay 24 V DC, 2 c/o | Automation Accessories | You are viewing this model |
Datasheets & Documents
- Datasheet ABB 1SVR405606R1000 CR-P024DC2G Gold-Contact Relay 24 V DC, 2 c/o Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SVR405606R1000 CR-P024DC2G Gold-Contact Relay
Answers from our engineering team on installation, compatibility and integration.
01What does the G in CR-P024DC2G stand for?
Gold contacts, an optional contact finish for the 2 c/o CR-P relays.
02What coil does 1SVR405606R1000 have?
24 V DC with 1440 ohm and 0.4 to 0.48 W.
03What is the contact rating of 1SVR405606R1000?
8 A thermal current at 250 V on each of the two c/o contacts.
04Which other gold CR-P versions exist?
CR-P024AC2G, CR-P110AC2G and CR-P230AC2G.
05Is 1SVR405606R1000 sealed?
The datasheet states a degree of protection of IP67 for the relay body.


















Reviews