Honeywell STT17H HART Head-Mount Temperature Transmitter
Description
Honeywell STT17H overview
The Honeywell STT17H is the HART version of the STT 3000 STT170 series of programmable temperature transmitters. It offers HART with 4 to 20 mA output, accepts RTD, thermocouple, ohm or millivolt inputs, and supports single or dual sensor input in difference or average mode.
Plants that run Honeywell STT17H units often need the exact model number as a spare. Seven Star LLC lists the STT17H for maintenance and projects teams in Oman and the GCC that need to keep a HART temperature point in service with the same model.
Key features of the STT17H
- HART and 4 to 20 mA output, with HART multidrop capability.
- RTD, thermocouple, ohm or mV input.
- Single or dual sensor input, with difference or average calculation.
- DIN form B head mount for sensor connection heads.
- NAMUR NE43 sensor error response.
- Configuration with the STT17C tool and PC.
The dual input mode makes the STT17H useful for temperature difference measurement across an exchanger, or for averaging two elements in a large vessel, without extra hardware in the control system.
STT17H technical specifications
The table below summarises the values published by Honeywell for the STT17H. Where a value depends on the communication protocol, the housing or an ordering option, the entry says so, and the full model selection guide in the datasheet remains the reference for exact option codes.
| Parameter | Value |
|---|---|
| Model | STT17H, part of the STT170 series |
| Output | HART with 4 to 20 mA |
| Inputs | RTD, thermocouple, ohm or mV |
| Sensor configuration | Single or dual input (difference or average) |
| Mounting | DIN form B head mount |
| Multidrop | HART multidrop capable |
| Sensor error response | NAMUR NE43 |
| Pt100 (IEC 60751) | -200 to +850 °C; basic accuracy 0.2 °C plus 0.1% of span; minimum span 10 °C |
| Pt1000 (IEC 60751) | -200 to +850 °C; basic accuracy 0.2 °C plus 0.1% of span; minimum span 10 °C |
| Ni100 (DIN 43760) | -60 to +250 °C; basic accuracy 0.3 °C plus 0.1% of span; minimum span 10 °C |
| Thermocouple K (IEC 584) | -180 to +1372 °C; basic accuracy 0.5 °C plus 0.1% of span; minimum span 50 °C |
| Thermocouple J (IEC 584) | -100 to +1200 °C; basic accuracy 0.5 °C plus 0.1% of span; minimum span 50 °C |
| Thermocouple T (IEC 584) | -200 to +400 °C; basic accuracy 0.5 °C plus 0.1% of span; minimum span 50 °C |
| Thermocouple R and S (IEC 584) | -50 to +1760 °C; basic accuracy 1 °C plus 0.1% of span; minimum span 100 °C |
| Thermocouple B (IEC 584) | +400 to +1820 °C; basic accuracy 1 °C plus 0.1% of span; minimum span 100 °C |
| Millivolt | -800 to 800 mV; basic accuracy 10 microvolt plus 0.1% of span; minimum span 5 mV |
| Ambient temperature effect (RTD) | 0.01 °C per 1.0 °C plus 0.01% of span |
| Configuration | STT17C configuration tool and PC |
The values above come from the STT17H-BN specification table of the Honeywell STT170 document. Accuracy is the greater of the fixed value and the percentage of span, and the datasheet adds the cold junction accuracy for thermocouple inputs to the basic accuracy.
Typical applications in Oman and the GCC
The STT17H is typically used in these settings.
- Oil and gas: heater, furnace and process line temperatures with thermocouple or RTD sensors.
- Utilities and power: flue gas, steam and metal temperature points.
- Water and wastewater: process and equipment temperature monitoring.
- Manufacturing and process plants: kilns, ovens, exchangers and utilities with HART asset management.
The input flexibility of the STT17H means one model can serve many points in a plant, which keeps the spares inventory small.
Selection and compatibility notes for the STT17H
Select the STT17H when the loop needs HART and a wide choice of RTD and thermocouple inputs. If only an RTD or ohm input and analog output are needed, the STT171 is the simpler member of the series.
Confirm the sensor type and span against the table, especially the minimum span, which ranges from 10 °C for RTDs to 100 °C for thermocouple types B, R and S.
For new installations, consider the SmartLine STT850 as the current model; keep the STT17H where like-for-like replacement is needed.
Installation and commissioning
Fit the STT17H into a DIN form B connection head and wire the sensor according to the wiring diagrams for RTD, thermocouple, resistance and millivolt inputs. Connect the two-wire loop for the HART communication.
Configure with the STT17C tool, or via HART where your host supports it, and set sensor type, range and error response.
Verify the loop with a calibrated source, and confirm the alarm response with the control system.
Maintenance and diagnostics
The NAMUR NE43 error response gives a defined alarm current on sensor failure. HART access allows remote diagnostics and range checks.
Routine care includes checking terminals and connection head seals, and verifying calibration at your site interval.
Keep the configuration record, because spares are configured to match the original.
Related products and ordering notes
Related items are the STT171 and STT173 of the same series, the STT17C configuration tool and the STT850 SmartLine transmitter. Probes and thermowells can be quoted together.
Quote the part number STT17H in your RFQ.
Frequently asked questions in brief
The questions below cover protocol, inputs, dual sensor mode and ordering for the STT17H, and each answer follows the Honeywell specification.
Documents and quotation
A Honeywell datasheet for the STT17H is attached to this page so your engineers can check ranges, materials and approvals before ordering. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request a quotation, send an RFQ that states the part number STT17H, the quantity, the measuring range or sensor type, the communication protocol and any display or approval requirement. We will confirm availability and lead time and reply with a written quotation.
Other Models in the Honeywell Stt170 Range
Seven Star LLC supplies models from the Honeywell Stt170 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Honeywell STT171 Head-Mount RTD Temperature Transmitter | Temperature Transmitters | View details |
| Honeywell STT17H HART Head-Mount Temperature Transmitter | Temperature Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Honeywell STT17H HART Head-Mount Temperature Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Honeywell is the American industrial technology group whose products on this site cover gas and flame detection, pressure transmitters, flow measurement, gas metering, fire alarm systems and helicopter rotor balancing equipment. Its roots go back to a thermostat business in Minneapolis in 1885 and to Mark Honeywell's heating company, which merged with it in 1927. Several brands we list have joined Honeywell over the years: Gent fire systems of Leicester (part of Honeywell since 2005), Chadwick-Helmuth (a Honeywell business unit from 2002) and Elster gas metering (acquired around the end of 2015).
Seven Star LLC is an independent supplier in Muscat. We list Honeywell gas detectors and sensors, transmitters, Elster gas meters and flow computers, Gent fire alarm equipment and Chadwick-Helmuth balancers, and supply them and their spares in Oman and the GCC by part number.
Honeywell company profile
| Origins | 1885, Minneapolis (Butz thermostat business); merged with Mark Honeywell's company in 1927 |
|---|---|
| Brands in our range | Honeywell Analytics gas detection, SmartLine transmitters, Elster gas metering, Gent fire detection, Chadwick-Helmuth rotor track and balance |
| Gent | Founded in Leicester, UK, around 1872 by John Thomas Gent; part of Honeywell since 2005 |
| Elster | Gas, water and electricity metering; bought by Honeywell from Melrose, deal completed around the end of 2015 |
Milestones
- 1885: The Butz thermostat business starts in Minneapolis.
- 1927: It merges with Mark Honeywell's company.
- 2005: Gent fire detection (Leicester, UK) becomes part of Honeywell.
- 2015: Honeywell completes the purchase of Elster from Melrose around the end of the year.
Honeywell products we list
| Family | Models | Typical use |
|---|---|---|
| Fixed gas detectors | Searchline Excel, Searchline Excel Plus, 02104-N-XSSA, Sensepoint XCD RTD, Sensepoint XCD IR, XCD H2, Sensepoint XCL, Sensepoint XRL, OmniPoint, RAEGuard 2 PID | Flammable, toxic and VOC gas detection in process areas |
| Sensors, flame detection and control | SR-W-MP75C LEL sensor, SR-X2V O2 sensor, FS24X Plus flame detector, R4343E flame switch, System 57 card, 5704FS panel | Replacement sensors, fire detection and gas detection control panels |
| Transmitters and flow | SmartLine STG700, STG800, STR82D remote seal, VersaFlow Coriolis | Process pressure and mass flow measurement |
| Elster gas metering | Q.Sonic plus, TRZ2, Quantometer, RABO, IRM-3 DUO, EK280, EC 350, enCore FC1, enCore ZM1, gas-net F1, gas-net D2, GasLab Q2, USM display | Gas meters, volume correction and fiscal flow computing |
| Gent fire alarm systems | Vigilon Plus, Vigilon Compact Plus, Nano, Xenex, S-Quad detector, S-Cubed, ALD302 base, S4-34420 interfaces, loop card, repeat panel, mimic panel, XENS-850 call point, 74430 bell | Addressable and conventional fire alarm systems in buildings and plants |
| Chadwick-Helmuth rotor track and balance | 8500C, 8500C Plus, Vibrex 2000, Model 11, photocell system, printer, bracket, protractor | Helicopter rotor track and balance and propeller balancing |
Gas detection uses two basic approaches. Point detectors such as the Sensepoint XCD measure the gas at one location, with a catalytic or infrared sensor for flammable gas and an electrochemical cell for toxic gas such as H2S. Open path detectors such as the Searchline Excel send an infrared beam across an area up to a few hundred metres long and detect a gas cloud anywhere along it. Infrared sensors cannot be poisoned the way catalytic beads can, which matters on sites with silicones or H2S.
Where Honeywell products are used
In Oman and the GCC, Honeywell gas detectors protect wellheads, gas plants, refineries and tank farms. Elster meters and flow computers measure gas at city gate stations and in industry. Gent systems are installed in commercial buildings, hospitals and hotels, and Chadwick-Helmuth balancers are used by helicopter operators.
Ordering Honeywell products: what we need
Send the part number from the label (for example 02104-N-XSSA or SPXCDASMTXF). For gas detectors, add the gas, range, output and certification. For gas meters, add size (DN), flow range and pressure rating. For Gent equipment, add the panel type and loop protocol.
Facts checked against Honeywell press releases and SEC filings, and published histories of Gent and Chadwick-Helmuth, October 2026.
Browse Honeywell products by category: Fire & Gas Detector, Vibration, Flowmeters, Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the Honeywell STT17H HART Head-Mount Temperature
Answers from our engineering team on installation, compatibility and integration.
01What output does the STT17H provide?
The STT17H provides HART with 4 to 20 mA output and is HART multidrop capable.
02What inputs does the STT17H accept?
RTD, thermocouple, ohm or millivolt inputs, in single or dual sensor configuration.
03Can the STT17H measure a temperature difference?
Yes, dual sensor input can be configured as a difference or an average of the two sensors.
04How is the STT17H configured?
With the STT17C configuration tool and a PC, as described in the Honeywell STT170 series document.
05How do I order the STT17H from Seven Star LLC?
Send an RFQ with the part number STT17H, quantity, sensor types and range. We reply with availability and a quotation.